• Title/Summary/Keyword: Electromagnetic pulse (EMP)

Search Result 44, Processing Time 0.026 seconds

A Method to Suppress the Spurious Radiation due to the Current Pulse on the Cable using the Frequency Selective Metamaterial Structure (주파수 선택도를 가지는 메타재질구조를 이용한, 선로상의 전류펄스에 의한 불요방사 억제기법)

  • Kahng, Sungtek;Yang, Inkyu;Kim, Hyeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.4
    • /
    • pp.517-522
    • /
    • 2013
  • The spurious electromagnetic radiation is generated due to the RF unbalanced current on a conductive cable connecting an electronic device to another. A metamaterial-based filtering geometry with frequency selectivity is suggested to reduce the radiation with a bandgap structure, where the right-handed inductance and capacitance stem from the transmission-like configuration between the cable and the metal protrusion, and the left-handed components come from the narrow cavities. The effect of the structure on the unbalanced current pulse and its spurious radiation is presented in the FDTD-method frame work.

Electromagnetic Pulse Shielding Effectiveness and Construction Availability of Cast-In-Place Structures Using Corrugated Metal-Plates

  • Kim, Suk Bong;Yoon, Sangho;Min, Gyung Chan;Ahn, Sungjin;Park, Young Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.1
    • /
    • pp.84-89
    • /
    • 2013
  • This study aims to examine the effectiveness of electromagnetic pulse shielding in cast-in-place protective shelters using corrugated metal-plates, and then reviews their usability for the Republic of Korea Army. The Korea Corps of Engineering has evaluated corrugated metal-plates as a construction material for cast-in-place structures, which have to defend against mechanical impacts as well as electromagnetic pulses. Corrugated metal-plate is known as a superb mechanical protective material, so much so that it has been employed in ammunition magazines and artillery platforms in the armed forces. Moreover, as a metal, such as steel and copper, it is universally recognized as one of the most effective electromagnetic pulse shielding materials. In addition to effectively shielding from electromagnetic pulses and protecting against mechanical impacts, corrugated metal-plates should prove to be an appropriate construction material for the cast-in-place protective shelter in terms of construction availability and economic feasibility. The shielding effectiveness of the suggested structures is examined based on MIL-STD 188-125-1. A few frequency bands need an increase of 15~30dB in shielding effectiveness because of unbidden apertures caused by flaws associated with welding, assembling, and material deformation. However, allowing for the approximately 40dB of shielding provided by soil; the examined structure, which is buried underground, can offset its shortcomings sufficiently.

Experimental Study on the Development of EMP Shielded Concrete Using Industrial By-products (산업부산물을 사용한 EMP차폐 콘크리트 개발에 관한 실험적 연구)

  • Min, Tae-Beom;Kim, Hyeong-Cheol;Choi, Hyun-Kuk;Roh, Jeong-Heon;Kim, Kuk-Joo;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.477-484
    • /
    • 2019
  • The purpose of this study is to present basic data for developing concrete with EMP shielding as the structure materials when constructing an EMP shielded building structure. In order to use metal-based recycled aggregates with excellent conductivity and easy procurement for EMP shielding concrete, an evaluation of the stability evaluation and EMP shielding performance was performed. Through the stability evaluation, it was found that the coarse aggregate stability criterion was satisfied, but the oxidized slag did not satisfy the fine aggregate stability criterion, the oxidized slag is not satisfied. In addition, as a result of fresh concrete, the workability is increased and the air volume is decreased. The compressive strength is increased due to the high density and coarse granularity of the recycled aggregates, which increased the cement paste and adhesion, thereby increasing the compressive strength. The results of an EMP shielding test show that aggregates with high shielding performance are electronic arc furnace(EAF) Oxidizing Slag and Cooper Slag. The shielding performance is expected to increase if the average particle size of aggregate is small or uniformly distributed.

Analysis of Shielded Twisted Pair Cable to External Field Coupling by Expanded Chain Matrix Modeling

  • Cho, Yong-Sun;Jung, Hyun-Kyo;Cheon, Changyul;Chung, Young-Seek
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.6
    • /
    • pp.2049-2057
    • /
    • 2014
  • In this paper, a numerical method for analyzing coupling between high-altitude electromagnetic pulse (HEMP) as external field and a shielded twisted pair (STP) cable is proposed, which is based on an expanded chain matrix. Load responses of electromagnetic (EM) field excitation in uniform transmission line (TL) are solved by Baum-Liu-Tesche (BLT) equations in frequency domain, however, it is difficult to apply BLT equations to solve load responses of STP cable because the iteratively changing configuration of each twisted pairs are involved in cable. To avoid this problem and decrease memory and CPU time, we proposed the expanded chain matrix modeling method that is calculated using ABCD parameters, and applied multi-conductor transmission line (MTL) theory to consider the EMP coupling effectiveness of each twisted pairs. The results implemented by the proposed method are presented and compared with those obtained by the finite-difference time domain (FDTD) method as a kind of 3D full wave analysis.

HEMP Analysis and Shielding Effectiveness (HEMP 분석과 방호 효율성)

  • Lee, Sun Yui;Kim, Jin Young;Park, Woo Chul
    • Journal of Satellite, Information and Communications
    • /
    • v.8 no.3
    • /
    • pp.20-24
    • /
    • 2013
  • In this paper, we introduce a concept of HEMP systems and analyze a shielding effectiveness by varying placements of the antenna elements. Maxwell's equations for the high frequency of the EMP is represented in the LOS. In order to investigate the effects of electromagnetic attenuations, a shielding room was constructed and employed to obtain measured data. Shielding effects were measured by changing frequency and the distance of receiving antenna. Each measured value was compared to U.S. standard and measuring method was simplified. shielding effects were measured by three different conditions of shielding room. Find the difference between forward measurement and reverse measurement and factors which affects the measurement in shielding room.

미래 사이버 전 능력 필요

  • O, Je-Sang
    • Defense and Technology
    • /
    • no.10 s.272
    • /
    • pp.52-57
    • /
    • 2001
  • 미래 전쟁에서 정보작전의 전 범위에 걸쳐 정보우세를 성취하기 위하여, 실시간 전투원의 공격 혹은 방어적인 조치를 가능하게 하기 위하여 실시간 탐지/타격 체계(sensor to shooter systems)의 기반구조가 국방정보통신체계로 구성되어야 한다. 또한 이러한 아군의 국방정보통신체계를 적의 공격으로부터 보호할 수 있는 능력을 구비하여야 하며, 반면에 유사시 적의 국방정보통신체계를 마비시킬 수 있는 정보공격 무기인 해커, 바이러스, 전자기파 폭탄(electromagnetic pulse bomb : EMP), 기타 사이버 무기 등을 확보하여야 할 것이다.

  • PDF

Review of Failure Mechanisms on the Semiconductor Devices under Electromagnetic Pulses (고출력전자기파에 의한 반도체부품의 고장메커니즘 고찰)

  • Kim, Dongshin;Koo, Yong-Sung;Kim, Ju-Hee;Kang, Soyeon;Oh, Wonwook;Chan, Sung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.6
    • /
    • pp.37-43
    • /
    • 2017
  • This review investigates the basic principle of physical interactions and failure mechanisms introduced in the materials and inner parts of semiconducting components under electromagnetic pulses (EMPs). The transfer process of EMPs at the semiconducting component level can be explained based on three layer structures (air, dielectric, and conductor layers). The theoretically absorbed energy can be predicted by the complex reflection coefficient. The main failure mechanisms of semiconductor components are also described based on the Joule heating energy generated by the coupling between materials and the applied EMPs. Breakdown of the P-N junction, burnout of the circuit pattern in the semiconductor chip, and damage to connecting wires between the lead frame and semiconducting chips can result from dielectric heating and eddy current loss due to electric and magnetic fields. To summarize, the EMPs transferred to the semiconductor components interact with the chip material in a semiconductor, and dipolar polarization and ionic conduction happen at the same time. Destruction of the P-N junction can result from excessive reverse voltage. Further EMP research at the semiconducting component level is needed to improve the reliability and susceptibility of electric and electronic systems.

A Study on Risk Assessments and Protection Improvement for Electric Power Infrastructures against High-altitude Electromagnetic Pulse (전력기반시설의 고 고도 핵 전자기파에 대한 위험성 검토 및 방호 개선방안 연구)

  • Chung, Yeon-Choon
    • Convergence Security Journal
    • /
    • v.19 no.3
    • /
    • pp.43-50
    • /
    • 2019
  • In a hyper-connected society, electric power infrastructures and information and communication infrastructures are the core of critical national infrastructures. However, electric power infrastructure is very deadly to high-frequency nuclear electromagnetic pulse (HEMP) threats recently issued by North Korea, so the resilience through rapid recovery after attack is directly related to the survivability of our country. Therefore, electric power infrastructure should take precedence over any other key infrastructure, with preemptive protection measures and fast recovery plans. In this paper, the characteristics of the HEMP threats was examined, and the risks and effective major protection measures of the electric power infrastructures are discussed. In the future, it is expected that it will be able to help establish the direction of enactment and revision of legal schems related to the 'high power EMP infringement prevention' for Korea's electric power infrastructures.

A Study on Optimizing Energy Transfer of Capacitive Switching Antenna (Capacitive Switching Antenna의 최적 에너지 전달에 관한 연구)

  • Kim, Jin-Man;Bang, Jeong-Ju;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.232-238
    • /
    • 2013
  • In this paper we describe the maximum energy transfer of CSA(Capacitive Switching Antenna). CSA which is radiated antenna system contain energy storage and switch, antenna needs to high voltage source for electrical field radiation experiment. In this experiment we employed Marx generator as a charging source. CSA can radiate electrical field more efficiently by varying antenna capacitance. The electromagnetic generation system which was using CSA has some advantages which are more simple and more effective compared to exist system. We evaluated the performance of electromagnetic wave generating system using CSA. As a result UWB gain of system is 0.47, It is higher level than exist system is 0.3. Radiated electrical field strength at 1m is 70kV/m. It is measured by D-dot sensor and gap distance is 20mm. Center frequency of CSA is approximately 25MHz. When vary the antenna gap distance from 50mm to 20mm, we can find the radiation field strength is decrease and antenna center frequency is increased. We also simulated the energy transfer efficiency to compare with experiment result. Consequentially, CSA needs to appropriate capacitance which is similar value from marx generator for maximum energy transfer, and gap is less than 1mm to increase the CSA capacitance.

Analysis of Low-Frequency Magnetic SE of a Metal Plate: Diffusion and Slot Effects (도체 판의 자기장 차폐효과 분석: 확산과 슬롯 효과)

  • Park, Hyun Ho;Kwon, Jong Hwa
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.4
    • /
    • pp.324-327
    • /
    • 2019
  • This study analyzes the low-frequency magnetic shielding effectiveness (SE) of a metal plate, in terms of diffusion and slot effects, by conducting a numerical simulation and implementing an analytical solution. When the metal has a low conductivity, the SE is dominated by the diffusion effect. However, when the conductivity and frequency both increase, the slot has a major influence on the SE. These results can be used as guidelines in the shielding design and SE requirements of electromagnetic pulse protection facilities.