• 제목/요약/키워드: Electromagnetic pressure

검색결과 209건 처리시간 0.025초

UHF 이중대역법을 이용한 GIS PD 분석 (GlSPD Analysis Using UHF Dual-Band Method)

  • 이상화;최재구;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.63-66
    • /
    • 2004
  • It is widely known that the ultra high frequency (UHF) method that detects the electromagnetic wave of the PD pulses in the gas insulated space is one of the most competitive methods for its high sensitivity. From the above point of view, this paper describes the characteristics of GIS PD signals measured with ultra wide band (UWB) GIS PD defecting system in which PD signals are defected into the dual UHF band. Thc UWB PD detection system consists of the UWB UHF coupler, the UWB low noise amplifier (LNA) and the oscilloscope. The dual bands for PD signals are 0.5-2GHz(full band) and 1-2GHz(high band). As results, it was found that the partial discharges of each defect have their own characteristic pattern and the ratio of High hand to Full band increases with gas pressure.

  • PDF

무향 수조 내에서의 음파 전파 특성 연구 (Wave Propagations in the Underwater Anechoic Basin in KRISO)

  • 김시문;최영철;박종원;임용곤
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.363-368
    • /
    • 2001
  • 수중에서는 광파 및 전자파의 급격한 감쇠 특성으로 인하여 원거리 수중 통신을 위해서 음파를 주로 사용한다 그러나 음파의 전파 특성은 시공간상으로 변화하는 해수의 온도, 압력, 염분 등에 따라 큰 영향을 받기 때문에 신호의 왜곡 현상이 발생하며 보다 정확한 정보 전달을 위해서는 신호 왜곡에 대한 현상을 반드시 파악하여야 한다. 본 논문에서는 실해역에서의 적용에 앞서 기본적인 해석으로서, 무향 수조 내에서의 가청주파수 영역 및 통신에 주로 사용되는 초음파 영역에서의 전과 특성을, 특히 신호 왜곡에 가장 큰 영향을 미치는 표면 반사에 대한 특성을 시간영역과 주파수 영역에서 분석 비교를 수행하였다.

  • PDF

Pulsed-GMAW의 금속 이행 현상에 관한 동적 해석 (Dynamic Analysis of Metal Transfer in Pulsed-GMAW)

  • 최상균;유중돈;박상규
    • Journal of Welding and Joining
    • /
    • 제15권5호
    • /
    • pp.84-91
    • /
    • 1997
  • The metal transfer phenomenon of the pulsed-GMAW is simulated by formulating the electromagnetic force incorporated with the Volume of Fluid algorithm. The free surface profiles, pressure and velocity distributions within the drop are computed numerically. Axial velocity and acceleration generated during peak current period are found to have a significant effect on drop detachment. Therefore, the accelerated inertia force becomes one of important factors affecting metal transfer in the pulsed-GMAW. When the pulse current parameters are selected properly, the molten drop is detached just after current pulse, and the operating range of the pulsing frequency increases with higher peak current and duty cycle. Calculated operating ranges show reasonably good agreements with the available experimental data.

  • PDF

용적 내부의 유동에 의한 모멘텀을 고려한 GMA 용접의 입상용적 이행에 대한 해석 (Analysis of Globular Transfer Considering Momentum Induced by Flow Within Molten Drop in GMAW)

  • ;이승현;강문진;유중돈
    • Journal of Welding and Joining
    • /
    • 제26권4호
    • /
    • pp.61-65
    • /
    • 2008
  • The static force balance model (SFBM) has been used to analyze drop transfer in gas metal arc welding. Although the SFBM is capable of predicting the detaching drop size in the globular mode with reasonable accuracy, discrepancy between the calculated and experimental results increases with current. In order to reduce discrepancy, the SFBM is modified by considering the momentum of the molten metal flow, which is generated by the pinch pressure. The momentum increases with smaller drop size and becomes compatible to the electromagnetic force. The modified force balance model (MFBM) predicts the experimental results more accurately, and extends its application to the projected mode.

헬리칼 공명 플라즈마에서 축 방향의 외부 자장이 기판상의 플라즈마 밀도에 미치는 영향 (Effects of axial external magnetic fields on plasma density on substrate in helical resonator plasma source)

  • 김태현;태흥식;이용현;이호준;이정해;최경철
    • 한국진공학회지
    • /
    • 제8권2호
    • /
    • pp.172-179
    • /
    • 1999
  • The axial distributions of plasma density in a helical resonator plasma with the external magnetic field have been measured using Langmuir probes. Net RF power is set to 200W and chamber pressure is varied from 0.4 mTorr to 100mTorr there are three kinds of eternal magnetic field structure applied on the helical resonator plasma. One is a uniform magnetic field, the second is a positive gradient magnetic field and the third is a negative gradient magnetic field. In the three magnetic field structures, the negative gradient magnetic field is found to show the highest increase in plasma density on the substrate compared with other magnetic structures. Plasma density profile in helical resonator is well consistent with electromagnetic field pattern obtained by computer simulation. It is also found that axial magnetic fields do not affect plasma density distribution in the plasma reactor region, but induce the increase of plasma density in the process chamber region. In order to avoid the nonuniformity of radial density profile, weak magnetic fields under 100G are applied.

  • PDF

AC 전압하에서 유리진공관의 방전현상 (Discharge Phenomena of Glass Tube Vacuum under AC Applied Voltage)

  • 최용성;황종선;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.371-372
    • /
    • 2008
  • In this paper, we experimentally investigated discharge phenomena inside vacuum interrupter at 1 to 20 Torr to simulate the vacuum leakage. We used glass type of vacuum interrupter where the internal pressure and the type of gasses can be varied according to requirement. The experiment is conducted under ac applied voltage and the experimental circuit is constructed to simulate the actual circuit used in cubical type insulated switchgear. We used two types of gases such as air and $SF_6$. The use of glass type vacuum interrupter allowed us to measure discharges occurring in vacuum interrupter optically. We measured and discussed the discharge occurring in both gases with a current transformer and ICCD camera. We also revealed that electromagnetic wave spectra emitted by the discharge have same frequency range for both gasses.

  • PDF

연X선 Ionizer에 의한 대전물체의 제전특성에 관한 연구 (A Study of De-electrification Characteristics of Charged Body By Soft X-Ray Ionizer)

  • 이동훈
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.67-73
    • /
    • 1998
  • The technology for neutralizing static electricity by soft X-ray radiation has been newly developed. This technology involves ionization of gas molecules in the vicinity of a charged substrate to generate ions and electrons to reduce electrostatic potential. The ULSI device substrate and liquid crystal display substrate tend to get charged instantly to a high potential level when they are handled in the manufacturing process. Soft X-ray radiation is adequate in air or $O_2$ gas at atmospheric pressure. This newly developed neutralization method is effective to be superior to the conventional technique, i.e., an ionizer by using corona discharge ,in every aspect. The new method features excellent neutralization capability and is able to completely reduce electrostatic potential to 0 V within a short time. Moreover, this is a very clean antistatic technology free from particle generation ,ozone generation, and electromagnetic noise, which are problems in using the corona discharge ionizer.

  • PDF

메탈헬라이드램프용 순시재점등 전자식안정기 개발 (The Development of Electric Ballast for a Instant Restart of Metalhalide Lamp)

  • 김수경;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.185-190
    • /
    • 2003
  • The most shortcoming of metalhalide lamps is what the instant restarting cannot be realized when the arc tube is in the hot condition. The discharge starting voltage of arc tube in the hot condition is much higher than in the cold condition. Therefore it takes about five minutes to restart the metalhalide lamps, that is to say, it is possible to start when the pressure and the temperature are decreased. But, if the lamp is restarted in the hot condition, we must supply the high voltage pulse with 20kV at the both sides of lamp. The proposed electronic ballast is consist of a electromagnetic interference (EMI) filter, a power factor correction (PFC) circuit, a flyback converter, a half-bridge inverter, and a high voltage igniter circuit. By this composition we can restart the lamp with the voltage 20kV, even if the lamp is in the hot condition.

  • PDF

주사 플라즈마 법(SPM)을 이용한 소수성 표면처리 (Control of Contact Angle by Surface Treatment using Sanning Plasma Method)

  • 김영기;최병정;양성채
    • 한국전기전자재료학회논문지
    • /
    • 제23권1호
    • /
    • pp.10-13
    • /
    • 2010
  • The plasma processing technologies of thin film deposition and surface treatment technique have been applied to many industrial fields. This study is purposed Large-area uniformity and surface treatment on the stainless substrate. We treat surface of stainless by $CF_4$ plasma. $CF_4$ plasma is generated by using SPM(Scanning plasma method)which is kind a of CVD. Generally, SPM has been used for uniform surface treatment using a crossed electromagnetic field. The optimum discharge condition has been studied for the gas pressure, the magnetic flux density and the distance between substrate and electrodes. In result, contact angle is increased by surface treatment using $CF_4$ Plasma. Therefore we expect that SPM to control contact angle is applied to many industries.

A Chemical Kinetic Model Including 54 Reactions for Modeling Air Nonequilibrium Inductively Coupled Plasmas

  • Yu, Minghao;Wang, Wei;Yao, Jiafeng;Zheng, Borui
    • Journal of the Korean Physical Society
    • /
    • 제73권10호
    • /
    • pp.1519-1528
    • /
    • 2018
  • The objective of the present study is the development of a comprehensive air chemical kinetic model that includes 11 species and 54 chemical reactions for the numerical investigation of air nonequilibrium inductively coupled plasmas. The two-dimensional, compressible Navier-Stokes equations coupled with the electromagnetic-field equations were employed to describe the fundamental characteristics of an inductive plasma. Dunn-Kangs 32 chemical-reaction model of air was reconstructed and used as a comparative model. The effects of the different chemical kinetic models on the flow field were analyzed and discussed at identical/different working pressures. The results theoretically indicate that no matter the working pressure is low or high, the use of the 54 chemical kinetic model presented in this study is a better choice for the numerical simulation of a nonequilibrium air ICP.