• Title/Summary/Keyword: Electromagnetic field analysis

Search Result 792, Processing Time 0.028 seconds

Force Control of Main Landing Gear using Magneto-Rheological Damper (MR 댐퍼를 이용한 주륜 착륙장치 하중제어기법 연구)

  • Hyun, Young-O;Hwang, Jae-Up;Hwang, Jae-Hyuk;Bae, Jae-Sung;Lim, Kyoung-Ho;Kim, Doo-Man;Kim, Tae-Wook
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.4
    • /
    • pp.344-349
    • /
    • 2009
  • To improve performance of the main landing gear for helicopters, a semi-active control landing gear is introduced in this paper. An MR damper based on commercial finite element electromagnetic field analysis of an electromagnet has been adapted the shock absorber. Force control algorithm (which maintains constantly the sum of air spring force and damping force as internal forces) which keep the sum of air spring force and damping force constant during landing, has been used for the controller, applied to control the semi-active landing gear. A series of drop simulations using ADAMS has been done with the passive, sky-hook control type, and force control type landing gears. The result of each simulation has been compared to evaluate the landing performance of the proposed force control type landing gear.

Measurement of Screening Effect by Metal Pipe on Induced Voltage to Communication Cable from Electric Railway (전기철도에서의 통신선 유도전압에 대한 금속관 차폐효과 측정)

  • Seol, Il-Hwan;Choi, Kyu-Hyoung;Lee, Sang-Mu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.2355-2362
    • /
    • 2014
  • Electric railway induces interference voltage on wayside communication cable which brings about communication errors, malfunction of devices, and safety problem. The magnitude of the induced voltage depends on the electromagnetic field coupling which is affected by metallic installations such as rail and track structures. This paper provides an experimental analysis of the screening effect of metallic pipe on the inductive voltage caused on communication cable. The measurements at a high-speed rail site show that the screening effect of metallic pipe is about 20% when the separation distance between the pipe and communication cable is 1~2 m. The screening effects is less than 1% and can be neglected when the separation distance is more than 4 m. These results are useful to evaluate the screening effects of the metallic installations such as water pipe, gas pipe, and reinforcing bar.

LEFT INFERIOR FRONTAL GYRUS RELATED TO REPETITION PRIMING: LORETA IMAGING WITH 128-CHANNEL EEG AND INDIVIDUAL MRI

  • Kim, Young-Youn;Kim, Eun-Nam;Roh, Ah-Young;Goong, Yoon-Nam;Kim, Myung-Sun;Kwon, Jun-Soo
    • Proceedings of the Korean Society for Cognitive Science Conference
    • /
    • 2005.05a
    • /
    • pp.151-153
    • /
    • 2005
  • We investigated the brain substrate of repetition priming on the implicit memory taskusing low-resolution electromagnetic tomography (LORETA) with high-density 128 channel EEG and individual MRI as a realistic head model. Thirteen right-handed, healthy subjects performed a word/nonword discrimination task, in which the words and nonwords were presented visually,and some of the words appeared twice with a lag of one or five items. All of the subjects exhibited repetition priming with respect to the behavioral data, in which a faster reaction time was observed to the repeated word (old word) than to the first presentation of the word (new word). The old words elicited more positive-going potentials than the new words, beginning at 200 ms and lasting until 500 ms post-stimulus. We conducted source reconstruction using LORETA at a latency of 400 ms with the peak mean global field potentials and used statistical parametric mapping for the statistical analysis. We found that the source elicited by the old words exhibited a statistically significant current density reduction in the left inferior frontal gyrus. This is the first study to investigate the generators of repetition priming using voxel-by-voxel statistical mapping of the current density with individual MRI and high-density EEG.

  • PDF

Experimental Evidence and Analysis of a Mode Conversion of Guided Wave Using Magnetostrictive Strip Transducer (자기변형 스트립 탐촉자에 의한 유도초음파 모드 변환에 대한 실험적 검증 및 해석)

  • Cheong, Yong-Moo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.93-97
    • /
    • 2009
  • An advantage of a magnetostrictive strip transducer for a long-range guided wave inspection is that the wave patterns are relatively clear and simple when compared to a conventional piezoelectric ultrasonic transducer. Therefore, if we can characterize the evolution of defect signals, it could be a promising tool for a structural health monitoring of pipes for a long period of time as well as an identification of flaws. However, when evaluating a signal during a realistic field examination, it should be careful because of some spurious signals or false indications, such as signals due to a directionality, multiple reflections, mode conversion, geometrical reflections etc. Mode converted signals from a realistic piping mockup were acquired and analysed. We found mode conversions between a torsional guided wave T(0,1) mode and a flexural F(1,3) or longitudinal L(0,2) mode generated by a magnetostrictive strip transducer. Based on the experimental observations, an interpretation of the source of the mode conversion is discussed in a viewpoint of electromagnetic properties and structure of the strip transducer.

Characterization Analyses for Direct Current Tumor Ablation (직류 전류 이용 종양세포치료의 특성 연구)

  • Yang, T.K.;Kim, J.H.
    • Journal of the Korean Vacuum Society
    • /
    • v.20 no.4
    • /
    • pp.307-312
    • /
    • 2011
  • As a technique for removing cancerous tumors from normal tissue, radio-frequency electromagnetic waves were employed to heating target cells up to the critical temperature, which kills the cancerous cells. However, its use in treating tumors in soft organs is limited by inconvenient factors, which are use of high-currents and long time operation. In this work, the feasibility of the localized heating by inserting four conducting electrodes with tiny direct current is investigated. The heat source is resulting from the electric field as known as resistive heating. We have investigated the temperature distribution as a function of applying DC voltages ranging from 10 V to 30 V with 10 V step. From the simulation results, the mushroom-like lesion shape by applying 20 V is generated by four electrodes within a few minutes, that is proper to the clinical application.

Applicability of the Small-Loop EM Method in the Sallow Marine Environment (천해 환경에서 소형루프 전자탐사의 적용성)

  • Song, Sung-Ho;Kim, Rae-Young;Kang, Hye-Jin;Cho, In-Ky
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.2
    • /
    • pp.152-157
    • /
    • 2011
  • The small-loop electromagnetic (EM) method is one of the rapid and non-destructive geophysical methods and has been used widely for many geophysical investigations, particularly for shallow engineering and environmental surveys. Especially in the shallow marine environment, the small-loop EM technique is very effective because of rapid and convenient data acquisition, large signal and low noise level. However, the method has been rarely applied in the very conductive marine environment since it's penetration or investigation depth might be considered too low. In this study, we demonstrated that the small-loop EM method can be effectively applied in the extremely conductive marine environment through the analysis of 1D small-loop EM data. Furthermore, we confirmed that the resistivity distribution under the sea bottom can be quantitatively predicted from the 1D inversion results of synthetic and field data.

Design and Fabrication of Semi-cylindrical Radar Absorbing Structure using Fiber-reinforced Composites (섬유강화 복합재료를 이용한 반원통형 전자파 흡수구조의 설계 및 제작)

  • Jang, Hong-Kyu;Shin, Jae-Hwan;Kim, Chun-Gon;Shin, Sang-Hun;Kim, Jin-Bong
    • Composites Research
    • /
    • v.23 no.2
    • /
    • pp.17-23
    • /
    • 2010
  • The stealth technology can increase the survivability of aircrafts or warships and enhance the capability of mission completion in hostile territory. The purpose of this paper is to present the low observable structure with curved surfaces made by fiber-reinforced composites and to show the possibility of developing omnidirectional stealth platforms for military applications. In this study, we developed a radar absorbing structures(RAS) based on a circuit analog absorber to reduce the radar cross section(RCS) of an object with curved surfaces. Firstly, the RAS with a periodic square patterned conducting polymer layer was designed and simulated using a commercial 3-D electromagnetic field analysis program. Secondly, the designed semi-cylindrical structure with low RCS was fabricated using fiber-reinforced composites and conducting polymer. To make the periodic pattern layer, acts as resistive sheet, the intrinsic conducting polymer paste containing PEDOT with a polyurethane binder was used. Finally, the radar cross section was measured to evaluate the radar absorbing performances of the fabricated RAS by the compact range facility in POSTECH.

Analysis of Signal Transfer Characteristics of Implantable Middle Ear System using Acoustic Model (청각모델을 이용한 이식형 인공중이 시스템의 신호 전달 특성 해석)

  • 송병섭;조진호
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.227-233
    • /
    • 2002
  • The IME(implantable middle ear) system is Promising due to its ability to free from sound feedback and Produce a good sound quality and intelligibility with low distortion even if it is operated with high gain for severe hearing impaired. The differential electromagnetic vibration transducer. which was developed for using in IME system and has two small magnets attached the same Pole facing in the coil. is not influenced by environmental external magnetic field. Besides, it has high vibration efficiency and good frequency response characteristics. In this Paper, using acoustic model of the transducer and ear model of normal Person. the signal transfer characteristics of the IME system are analyzed and investigated From the differences of the characteristics between normal ear and the IME system, it is Possible that design of the IME system that have the signal transfer characteristics similar to normal person's ear.

Analysis of Position Accuracy for Underground Facility Using RTK-GPS (RTK-GPS를 이용한 지하시설물의 위치 정확도 분석)

  • 박운용;이종출;정성모
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.21 no.3
    • /
    • pp.237-243
    • /
    • 2003
  • The complicated facilities on the ground have begun to be laid under the ground as increasing emphasis on the beauty of cities due to centralization. But, as the kind of the facilities have been concentrated on the narrow area, accidents occur due to the difficulty of maintenance and the inaccuracy of location information. In this study, first we constructed the field test model to compare with the method of underground probing. So, we could know that the electromagnetic induction method and GPR(Ground Penetration Radar) are useful. It was acquired the position information for the underground facilities using a RTK-GPS. As the result, we have analyzed the accurate position of the underground facility and show the way improving accuracy in detecting and surveying comparing with the traditional surveying method. Also, we hope to contribute the effective maintenance and prevention of disasters to the underground facility as using underground facilities 3D position with Arcview and building the DB of exact depth and underground facilities information system.

Design of a IMVA Single-Phase HTS Power Transformer

  • Kim, Sung-Hoon;Kim, Woo-Seok;Park, Chan-Bae;Hahn, Song-yop;Park, Kyeong-Dal;Joo, Hyeong-Gil;Hong, Gye-Won
    • Progress in Superconductivity
    • /
    • v.4 no.1
    • /
    • pp.86-89
    • /
    • 2002
  • In this paper, the design of a IMVA single-phase high temperature superconducting(HTS) power transformer with BSCCO-2223 HTS tapes is presented. The rated voltages of each sides of the transformer are 22.9 ㎸ and 6.6 ㎸, respectively The winding of 1MVA HTS transformer is consisted of double pancake type HTS windings, which have advantages of insulation and distribution of high voltage, and are cooled by subcooled liquid nitrogen of 65K. Four HTS tapes were wound in parallel for the windings of low voltage side and the four parallel conductors are transposed. The design of 1MVA HTS transformer, a shell type core made of laminated silicon steel plate is chosen, and the core is separated with the windings by a cryostat with a room temperature bore. The cryostat made of non-magnetic and non-conducting material and a liquid nitrogen sub-cooling system is designed in order to maintain the coolant's temperature of 65K. For electromagnetic analysis of 1MVA HTS transformer, a finite element method of an axis of symmetry is used. The maximum perpendicular component of magnetic flux density of pancake windings is about 0.15T. And through analyzing the magnetic field distribution, an optimal winding arrangement of 1MVA HTS transformer is obtained.

  • PDF