• Title/Summary/Keyword: Electromagnetic Energy

Search Result 697, Processing Time 0.026 seconds

Industrial Infrastructure Technologies for the Methane Energy-based Society and the Role of Microwaves

  • Katori, Yoshishige
    • Journal of electromagnetic engineering and science
    • /
    • v.10 no.4
    • /
    • pp.256-262
    • /
    • 2010
  • This paper discussed the following. 1. After reaching the final phase of an oil-based society, a resource-saving and -recycling "Methane Energy-based Society" will come about because of limited natural resources. 2. Industrial Infrastructure Technologies which support the Methane Energy-based Society will cause a paradigm shift in the area of industrial, transportation and civilian sectors. 3. The Non-communication application technology of microwaves plays an important role as one of the core element technologies which comprise new industrial infrastructure technologies.

Analysis of Electrical Characteristics Due to Deterioration of Electromagnetic Contactor (전자접촉기 열화에 따른 전기적 특성 분석)

  • Choi, Sun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.32 no.5
    • /
    • pp.407-412
    • /
    • 2019
  • In this paper, the changes in the electrical characteristics (arc energy, contact resistance, and bouncing phenomenon) due to the deterioration of the contact are analyzed. The results are generally consistent and can be analyzed for contact deterioration. The results of the experiment demonstrate that the arc energy is linearly related to the current when the contact samples and the voltage conditions are the same. The contact resistance varies due to multiple factors, but is generally within a certain range, and the contact deterioration can be determined. Contact stabilization can be detected by the decrease in the bouncing phenomenon due to deterioration (the change of the shape of the contact).

Radiated Electromagnetic Field Calculation due to Arc Discharge according to Speed of High Speed Train (고속철도의 속도에 따른 아크에 의한 전자파 방사 계산)

  • Han, In-Su;Lee, Tae-Hyung;Cho, Hong-Shik;Park, Choon-Soo;Kim, Ki-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.98-100
    • /
    • 2011
  • High speed Train Systems are the energy supplied system via the pantograph through which the voltage and the current supplied by the catenary wire flow. The arc discharges generate owing to the contact loss between the catenary and the pantograph, and the electromagnetic fields radiate. There are many different phenomena between the static charges and the moving charges in view of the radiated electromagnetic fields. To calculate the electromagnetic filed about the moving charges, it is necessary to adapt Lorentz transformation. Actually, the particle which moves near the speed of light has the relativisitic phenomena. In addition, it is necessary to predict the electromagnetic field because the radiated electromagnetic field takes effect on the near electronic devices and the human beings. In this paper, we model the arc discharge into the dipole antenna model, adapt Lorentz transformation to the case that the electric railway cars move, and calculate the radiated electromagnetic field. By the calculation, we take the basis upon the electromagnetic prediction, and apply to the future research.

  • PDF

A Study on Radiated and Conducted Noise for Small Electrical Energy Storage System due to Its Operating State (소형 전기에너지저장장치 운전조건에 따른 방사 및 전도 방해에 관한 연구)

  • Jung, Jeong-Il;Ahn, Gun-Hyun;Kim, Young-Sung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.1
    • /
    • pp.18-22
    • /
    • 2015
  • When using a secondary battery in energy storage units, if the grid is in light duty the active power is stored so it can be used when the grid is in heavy duty. This makes possible for the load equalize and make the grid optimized. Recently the government is trying to propagate this technology. Depending on its capacity this kind of electric energy storage unit is used in adjusting the frequency, break up the energy peak in summer and winter, stabilize the energy output of renewable energy which can change unstably because of the environment. Which makes it possible to stabilize the grid. It is anticipated that market of 120 trillion won will be developed worldwide in 2030. Currently in Korea a steady supply is in progress. However because of stray electromagnetic waves some other electronics are malfunctioning. This paper covers the research in the method to detect the emission noise in small electric energy storage units using lithium secondary batteries and battery management system, Power conditioning systems with CIPSR standards. And the research of a more efficient method to measure such stray electromagnetic waves.

Analysis and Design of Hybrid Electromagnetic Linear Actuator for Linear Pump (리니어 펌프 구동용 하이브리드 전자기 리니어 엑츄에이터 해석 및 설계)

  • Lee, Jung-Hun;Kim, Jin-Ho;Lee, Jae-Yong;Jeong, Sang-Hyun;Han, Bang-Woo
    • Journal of the Korean Magnetics Society
    • /
    • v.20 no.1
    • /
    • pp.28-33
    • /
    • 2010
  • The purpose of this paper is to analyze and design a new hybrid electromagnetic linear actuator for linear pumps. Solenoid linear actuator is widely used because it occupies small space due to no mechanical energy conversion system. In addition, the energy loss is very low and it has no noise. Conventional solenoid linear actuator, however, has the critical drawback of high power consumption. In this research, we present a new hybrid electromagnetic linear actuator using a permanent magnet in order to reduce power consumption. The enhanced performance of the hybrid linear actuator was verified by dynamic finite element analysis.

Investigation of Relation between EFTB Test and RF Conductive Immunity Test Using BER and Baseband Signal

  • Kuwabara, Nobuo;Irie, Yasuhiro;Hirasawa, Norihito;Akiyama, Yoshiharu
    • Journal of electromagnetic engineering and science
    • /
    • v.11 no.4
    • /
    • pp.274-281
    • /
    • 2011
  • High-speed telecommunication systems are influenced by electromagnetic environments because they need a wide bandwidth to transmit signals. Immunity tests of telecommunication equipment are effective for improving its immunity to electromagnetic environments. However, immunity tests are expensive to carry out because there are several different tests. The correlation among the tests should therefore be examined in order to reduce the kinds of tests that are necessary. This paper investigates the correlation between the electrical fast transient/burst (EFTB) test and the radio frequency (RF) conductive immunity test. Imitation equipment was constructed with a balun, and a baseband signal was transmitted from the associated equipment to the imitation equipment. Then, disturbances were applied to the equipment, and the telecommunication quality was evaluated by using the bit error rate (BER). The results from the EFTB test indicated that the BER was less than $6{\times}10^{-5}$ and the value was independent of the peak value. The results from the RF conductive immunity test indicated that the BER was affected by the longitudinal conversion loss (LCL).

Numerical Analysis of Electromagnetic Characteristic of High Voltage/Current Cable for Fuel Cell Electric Vehicle (FCEV) (수소 연료전지 차량용 고전압 케이블의 전자파 특성 수치해석에 관한 연구)

  • Lee, Soon-Yong;Choi, Jae-Hoon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.21 no.3
    • /
    • pp.149-157
    • /
    • 2010
  • The electromagnetic characteristics of FCEVs (fuel cell electric vehicles) are much different from the existing combustion engine cars as well as hybrid, plug-in-hybrid, and pure electric vehicles due to the high voltage/current generated by a fuel cell stack which uses a compressed hydrogen gas reacted with oxygen. To operate fuel cell stack efficiently, BOP (Balance of Plant) is essential. BOP systems are used many not only for motors in water pump, air blower, and hydrogen recycling pump but also inverters for these motors. Since these systems or components are connected by high voltage cables, EMC (Electromagnetic compatibility) analysis for high voltage/current cable is the most important element to prevent the possible electric functional safety errors. In this paper, electromagnetic fields of high current/voltage cable for FCEVs is studied. From numerical analysis results, time harmonic magnetic field strength of high current/voltage cable have difference of 20~28 dB according to phase. EMI result considered ground effect of FECV at 10 m shows difference of 14.5 dB at 30 MHz and 2.8 dB at 230 MHz compared with general cable.

Numerical Study of Estimating the Arrival Time of UHF Signals for Partial Discharge Localization in a Power Transformer

  • Ha, Sang-Gyu;Cho, Jeahoon;Lee, Juneseok;Min, Byoung-Woon;Choi, Jaehoon;Jung, Kyung-Young
    • Journal of electromagnetic engineering and science
    • /
    • v.18 no.2
    • /
    • pp.94-100
    • /
    • 2018
  • Partial discharges (PDs) are electrical sparks that occur inside insulation between two conducting electrodes and can lead to the disastrous failure of insulation systems. To determine the location of a PD, a distributed array of UHF PD sensors is used to detect the electromagnetic (EM) signals emitted from the PD source, and the localization of the PD source can be estimated using the time difference of arrival (TDOA) between EM signals captured by the UHF PD sensor array. There are four popular methods to estimate the TDOA-the first peak method, the cross-correlation method, the energy criterion method, and the average time window threshold method. In this work, we numerically investigate the influence of noise on estimating the TDOA for the four different methods. Numerical results show that the energy criterion method is more robust against noise than other methods.

Preparation and Electromagnetic Properties of an Electromagnetic Wave Absorber

  • Sun, Chang;Sun, Kangning;Pang, Laixue;Liu, Jian
    • Journal of Magnetics
    • /
    • v.21 no.1
    • /
    • pp.61-64
    • /
    • 2016
  • In this study, we report the as-prepared MgO-doped $BaFe_{12}O_{19}$, which was prepared by calcination technique and high-energy ball milling process, as an electromagnetic wave absorber. The phase analysis of $BaFe_{12}O_{19}$ and the as-prepared MgO-doped $BaFe_{12}O_{19}$ was detected utilizing X-ray Diffractometer (XRD). The microstructure was characterized using Scanning Electron Microscope (SEM). By means of the transmission/reflection coaxial line method, the electromagnetic properties and microwave absorbing properties of the as-prepared electromagnetic wave absorber were studied. It is found that the electromagnetic wave absorber has a minimum reflection loss value of -41 dB at 4.27 GHz with a matching thickness of 2.6 mm. The experiment results revealed that the as-prepared electromagnetic wave absorber could find potential applications in many military as well as commercial industries.

Study on the Distribution of Electromagnetic Force for 154 kV Power Transmission Cable on Dual Underground Lines by Normal and Earth Fault Current (지중 2회선 154 kV 송전케이블의 정상 및 지락고장에 따른 전자기력 분포에 관한 연구)

  • Kim, Hui Min;Kim, So Young;Im, Sang Hyeon;Park, Gwan Soo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • The goal of this study is the size and distribution of the electromagnetic force generated by the current flowing through the second underground line of 154kV power transmission cables by using electromagnetic finite element analysis. So we interpret how mutually electromagnetic force has an effect on the comparable judgement of Trefoil, Duct and Flat, which shows in a numerical arrangement. 154kV OF 1200SQ Cable 1.281km not only is applicable to modeling for underground transmission cable but also examine the effect of line to line, phase to phase and size and direction of the electromagnetic force preparing for the occurrence of normal state and single-phase earth fault, which are arranged in trefoil, duct and flat formation between sections. As showing how the trajectory, and size distribution of the electromagnetic force translate as the arrangement of the cables when a steady-state current and a fault current flows on the underground cables, I hope that when Underground transmission is designed, this data will be useful information.