• Title/Summary/Keyword: Electrolytic characteristics

Search Result 187, Processing Time 0.024 seconds

Dehydration characteristics of Magnesium Chloride Hydrate (함수(含水) 염화(鹽化)마그네슘의 탈수(脫水) 특성(特性) 고찰(考察))

  • Eom, Hyoung-Choon;Yoon, Ho-Sung;Park, Hyung-Kyu;Kim, Chul-Joo
    • Resources Recycling
    • /
    • v.16 no.5
    • /
    • pp.8-12
    • /
    • 2007
  • Anhydrous magnesium chloride, dehydration product from magnesium chloride hydrate is a general raw material to prepare electrolytic magnesium. However, the dehydration is not trivial and can be accompanied by hydrolysis leading to the production of undesirable hydroxy chloride compounds of magnesium. Therefore, dehydration process is actually the most complicated and hardest in the electrolysis methods for the production of magnesium. In this work, the influence of dehydrating temperature has been studied at the temperature range from $200^{\circ}C$ to $600^{\circ}C$ in air and HCl gas atmosphere individually to compare the results. With increasing of dehydration temperature MgOHCl and MgO were obtained in air. On the other hand, when the temperature was increased above $300^{\circ}C$ anhydrous magnesium chlorides were prepared in HCl gas atmosphere. Anhydrous magnesium chloride was formed at near $300^{\circ}C$ and completely crystallized at about $500^{\circ}C$. All of the HCl used as atmosphere gas in the dehydration was recovered as hydrochloric acid solution at a water vessel up to 41% by weight at $20^{\circ}C$.

Characteristics of Fluoride Releasing of Anodized Titanium Implant (양극산화 아크방전 처리한 티타늄 임플란트의 불소방출 특성)

  • Kim, Ha-young;Song, Kwang-yeob;Bae, Tae-sung
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.4
    • /
    • pp.361-369
    • /
    • 2008
  • The purpose of this study is to make porous oxide film on the surfaces of pure Ti through anodic spark discharge in electrolytic solution containing calcium and phosphate ions, to improve osseointergration by treating fluoride agent. In addition, it is to evaluate the fluoride modified effect on the surface. Commercial pure Ti plate with $20{\times}10{\times}2mm$ and Ti wire with a diameter of 1.5mm and a total length of 15mm were used. After making titanium oxide films converted by anodic spark discharge, anodizing was performed. Fluoride was spreaded to titanium laboratory plate and maintained for 30 minutes after anodizing breakdown. Fluoride ion discharge amount was measured per 24 hours after dipping titanium plate into saline (10ml) and sustaining 90rpm in a pyrostat. Some plates and wires were dipped in Hanks solutions for a month to examine biocompatibility using SEM and XRD. $TiO_2$ film formed by anodic discharge technique showed great roughness and uniform pores which were $1{\sim}3{\mu}m$ in a diameter. Roughness of the films treated with anodic discharge after blasting were higher than the turned ones(P<0.05). Rapid surface activity was observed in the samples treated with $TiF_3$ agent, which immersed in Hanks solution for 30 days. Taking the results into consideration, the fluoride modified implant with anodic discharge demonstrates that it makes uniformly porous oxide film on the surface of implant and properly increase roughness for osseointegration. The implants will achieve greater bone integration after short healing time by improving surface activity.

A Study on the Corrosivity according to Soil Characteristics and Electrolytic Protection for the Materials of Fuel Gas Pipe (토양 특성 및 전기방식에 따른 연료 가스용 강관의 부식 차이에 관한 연구)

  • Yim, Sang-Sik;Kim, Ji-sun;Ryu, Young-don;Lee, Jin-Han
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.6
    • /
    • pp.16-22
    • /
    • 2016
  • Coating pipe(PLP) has been generally used in buried site for protecting the corrosion. To prevent the damage by occurring the defect, other construction or execution works, an anti-oxidation environment was forcibly made by using protective potential. Coating and protective potential are applied simultaneously, but corrosion rate or defects are not easy to observe because soil composition has many uncertainty. Also, defect of coating pipe can not be directly observed. A corrosion coupon can easily measure a corrosion rate directly. The corrosion rate was measured with 6 scenarios using corrosion coupon during about 1 year(6 scenarios are based on soil type and protective potential or not in this research. Resultingly, the corrosion coupon has not occurred in the case of protected by potential current, but corrosion has occurred in a non-protected site. The corrosion rate was measured at least in the clay, and the propensity of corrosion rate was similar in other soil(sand and loams). The local corrosion has occurred in the clay because of high water content. On the other hand, general corrosion was occurred in sand and loams. Commonly, sand is not to corrosive soil. Although, corrosion occurred in sand can be estimated by chemical component and valid with chemical analysis report.

Development of optimal cross-section design methods for bored utility tunnels: case study of overseas typical cross-sections and design criteria (터널식 공동구 최적단면 설계기술 개발: 해외 표준단면 사례 및 설계기준 분석)

  • Park, Kwang-Joon;Yun, Kyoung-Yeol
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.20 no.6
    • /
    • pp.1073-1090
    • /
    • 2018
  • Since the domestic utility tunnels were built mainly in the development project of the new city, they are all in the form of cut-and-cover box tunnel. But, in the case of overseas construction of utility tunnels for existing urban areas, the bored tunnel types are mainly adopted. It is reasonable to install bored tunnels in a downtown area because it is difficult to block the roads or install bypass roads due to heavy traffic and civil complaints. In order to activate the utility tunnels in bored type, it is necessary to secure optimized cross-sectional design technology considering the optimal supplying capacity and mutual influencing factors (Thermal Interference, electrolytic corrosion, efficiency of the maintenance, etc.) of utilities (power cables, telecommunication cables, water pipes, etc.). The optimal cross-section design method for bored utility tunnels is ultimately to derive the optimal arrangement technique for the utilities. In order to develop the design methods, firstly, the cases of tunnel cross-section (Shield TBM, Conventional Tunneling) in overseas shall be investigated to analyze the characteristics of the installation of utilities in the section and installation of auxiliary facilities, It is necessary to sort out and analyze the criteria related to the inner cross-section design (arrangement) presented in the standards and guidelines.

Initial Charge/Discharge of $LiCoO_2$ Composite Cathode with Various Content of Conductive Material for the Lithium ion Battery (리튬이온전지용 $LiCoO_2$정극의 도전재료에 따른 초기 충방전 특성)

  • Doh Chil-Hoon;Moon Seong-In;Yun Mun-Soo;Yun Suong-Kyu;Yum Duk-Hyung;Park Chun-Jun
    • Journal of the Korean Electrochemical Society
    • /
    • v.2 no.3
    • /
    • pp.123-129
    • /
    • 1999
  • Initial electrochemical characteristics of $LiCoO_2$ electrode for lithium ion battery with various content of super s black as conductive material were evaluated through the charge/discharge with the potential range of 4.3V to 2.0V versus $Li^+/Li^+$. The rate of C/4 and C/2 by the 3 electrode test cell composed with an electrolytic solution of 1 mol/l $LiPF_6/EC+DEC(1:3\;by\; weight)$. Lithium was used as reference electrode. High impedance charge behavior was observed at early stage of charge. In the case of $3\%w/w$ of super s black as conductive material, the specific resistance of the high impedance releasing was $3.82\;{\Omega}\;{\cdot}\;g-LiCoCo_2$ at the current density of $0.5 mA/cm^2$, which corresponds 7 times of the specific resistance of electrode $(0.728 g-LiCoO_2)$. At second charge, the specific resistance of the high impedance releasing was 63 mn · g-Lico02, which corresponds 12eio of the specific resistance of electrode and only $1.7\%$ of that of the first charge. The first charge and discharge specific capacities at C/4 rate were 160-161 and $153\~155mAh/g-LiCoO_2$, respectively, to lead $95.4\~96.4\%$ of coulombic efficiencies and ca. $6 mAh/g-LiCoO_2$ of initial irreversible specific capacity. Specific resistance at the end of charge and rest showed low value at content of super s black between 2 and $7\%w/w$, which agreed with characteristics of irreversible specific capacity. Capacity densities were reduced by the increasing the content of conductive material. They were 447 and 431mAh/ml when 2 and $2.9\%w/w$ of super s black were used, respectively, at the rate of C/4.

Removing High Concentration Nitrogen by Electrolysis (전기분해에 의한 고농도 질소 제거의 특성)

  • Gil, Dae-Soo;Lee, Byung-Hun;Choi, Hae-Kyoung;Kwon, Dong-Min
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.2
    • /
    • pp.265-277
    • /
    • 2000
  • Laboratory experiments were conducted to investigate characteristics for removing ammonia-nitrogens by electrolysis methods. A stainless steel plate is used as the cathode and either $IrO_2{\backslash}Ti$ plate serves as the anode. Experiments were conducted to examine the effects of the operating conditions, such as the current density, retention time, electrode gap, $Cl^-/NH_4{^+}-N$ on the $NH_4{^+}-N$ removal efficiency. Possible optimum range for these operating variables are experimentally determined. The $NH_4{^+}-N$ removal efficiencies between plate type anode and net type anode were about same effect, but electrolytic power using net type anode is low than plate type anode. The $Cl^-/NH_4{^+}-N$ ratio was about $20.0kgCl^-/kgNH_4{^+}-N$ when $NH_4{^+}-N$ removal obtained 73 %, $Cl^-/NH_4{^+}-N$ ratio needs $27.6kgCl^-/kgNH_4{^+}-N$ so as to $NH_4{^+}-N$ completely remove. The removal efficiency of $NH_4{^+}-N$ increase with current density, retention time and $Cl^-/NH_4{^+}-N$ ratio, but decreased with increasing electrode gap. The relationship of operating conditions and $NH_4{^+}-N$ removal efficiencies are $$NH_4{^+}-N_{re}(%)=14.5364(Current\;density)^{0.7093}{\times}(HRT)^{1.0060}{\times}(Gap)^{-0.9926}{\times}(Cl^-/NH_4{^+}-N)^{1.0024}$$ With adding COD or/and alkalinity, relationships are $$NH_4{^+}-N_{re}(%)=9.8408(Current\;density)^{0.6232}{\times}(HRT)^{1.0534}$$ There existed a competition between the removals for $NH_4{^+}-N$ and $COD_{Cr}$ during electrolysis, the removal of $NH_4{^+}-N$ was shown to be dominant. $NH_4{^+}-N$ removal was high as addition of glucose and alkalinity.

  • PDF

A Study of Content Analysis on ICU(Intensive Care Unit) Nurses' Knowledge of Basic Nursing Sciences (중환자실 간호사의 기초간호과학 지식의 필요성 분석)

  • Byeon, Young-Soon;Choe, Myoung-Ae;Kim, Hee-Seung;Park, Mi-Jung;Seo, Wha-Sook;Lee, Kyung-Sook;Choi, S-Mi;Hong, Hae-Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.4 no.1
    • /
    • pp.41-49
    • /
    • 2002
  • The purpose of this study was to identify the knowledge contents of basic nursing sciences needed by nurses in the practices of the intensive care unit(ICU). To attain the goal of this study, the nurses working at 10 hospitals in the areas of Seoul and Kangwon Province were randomly selected. They were primarily interviewed, and the open question was secondarily put to them through the questionnaire. In the process of the 1st interview, the interviewees were asked of the question, "What is the knowledge of basic sciences such as anatomy, pathology, physiology. microbiology, pharmacology and the like thought to be lacking when you communicate with doctors in the ICU and when you carry out your nursing practices in it?" The contents of the interview were tape-recorded. The period of data collection ranged from May 1, 2001 to Sept 30. The interviews were conducted with total of 20 nurses. The open-end questionnaire was secondarily mailed to nurses. 113 questionnaires were returned. 100 questionnaires except 13 ones thought to be poorly completed in content were used for data analysis. Three coders classified data obtained from the interview and the questionnaire research into 5 detailed items relating to such as anatomical physiology, pathology, pharmacology. microbiology and basics of nursing. The three coders had experiences in nursing education of 18 years, 8 years and 6 years, respectively, and of them one coder was professor in basic nursing sciences. Data were statistically treated using frequency analysis and percentage by the SAS program. As a result, the following findings were obtained : It was found that the contents that ICU nurses responded were most needed in the field of Human structure and function were water and electrolytic balance(38%), blood and circulatory system(20%), changer in the patient's skin(12%), the arrangement of the human body(10%) and the endocrine system(10%), nervous system(6%), and assessment of the state of the patient's consciousness(4%). It was found that the contents that ICU nurses responded were most needed in the field of pathology were found to be the process of the progress of the disease(32%), symptoms of the disease(27%), prognosis of the disease(22%), followed by the injury-healing process, clinical pathological examination, and examination by radiation. It was found that the contents that nurses responded were most needed in the field of pharmacology were the effect of drug(25%), the side effect of drug(22%), the relationship between diseases and drug(20%), the relationship between disease-causing bacteria and drug(20%) and chemotherapy(2%). It was found that the contents that ICU nurses responded were most needed in the field of microbiology were the relationship between diseases and disease-causing bacteria(45%), Kinds and characteristics of disease-causing bacteria(18%), infection control(16%), application of the aseptic technique(12%), isolation(9%) and the like. It was found that the basic knowledge that ICU nurses responded were needed were the identification of the patient's current state(36%), understanding of the therapeutic process(22%), the operating principle of medical equipment and instrument(20%), medical terminology(9%), equipment and instrument management(7%), calculation of the dose of injection(2%) and the like.

  • PDF