• Title/Summary/Keyword: Electrolytic characteristics

Search Result 187, Processing Time 0.029 seconds

Characteristics of Electrolyzed Water Manufactured from Various Electrolytic Diaphragm and Electrolyte (전기분해 격막 및 전해액에 따른 전해수의 특성 비교)

  • 정진웅;김종훈;김병삼;정승원
    • Food Science and Preservation
    • /
    • v.10 no.1
    • /
    • pp.99-105
    • /
    • 2003
  • This study was carried out to investigate the efficacy of surface sterilization and the physicochemical properties of electrolyzed water manufactured from various electrolytic diaphragm and electrolyte. Physical properties of electrolyzed water manufactured from the diaphragm system were the most effective at the following conditions; the distance between diaphragms was 1.0 mm and the supplying rate of 20% NaCl was 6 mL/min. The ORP, HClO content and pH at above conditions were 1,170 mV, 100 ppm and 2.5, respectively. And two stage electrolyzed system was more effective than one stage electrolyzed water manufactured from non-diaphragm system, with 4 mL/min supplying rate of 20% NaCl, was similar to the most effective diaphragm system. But ORP, HClO content and pH were abut 800 mV, 200 ppm and 9 level, respectively. Sealed electrolyzed water could be preserved more than one month at room temperature with ORP of 750 mV in non-diaphragm system and 1,150 mV in diaphragm system, and HClO content of 100 ppm. Twelve kinds of microorganism tested were sterilized within 30 seconds from initial total counts of 10$\^$5/∼10$\^$6/cfu/ml by electrolyzed water. Though the ORP and HCIO contents of electrolyzed water manufactured from various electrolyte were higher in order of NaCl>KCl>CaCl$_2$, there were no difference between the electyolytes in the efficacy of sterilization. Salmonella typhi and Vibrio Proteolyticus were also sterilized by electrolyzed water manufactured from elctrolytes of NaCl CaC1$_2$and KCl

The Characteristics of the Hydrogen Embrittlement for the Cr-Mo Steels in Use of Pressure Vessel (압력용기용 Cr-Mo강의 수소취화 특성)

  • Lee, Hwi-Won;Yang, Hyun-Tae;Kim, Sang-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.6
    • /
    • pp.1107-1113
    • /
    • 2002
  • This study presents the hydrogen emblittlement in the metal, which decreases the ductility and then induces the brittle fracture. The contribution deals with the effect of strain rate and notch geometry on hydrogen emblittlement of 1.25Cr-0.5Mo and 2.25Cr-1Mo steels, which are in use at high pressure vessel. Smooth and notched specimens were examined to obtain the elongation and tensile strength. For charging the hydrogen in the metal, the cathodic electrolytic method was used. In this process, current density is maintained constant. The amount of hydrogen penetrated in the specimen was detected by the hydrogen determenator(LECO RH404) with the various charging time. The distribution of hydrogen concentration penetrated in the specimen was obtained by finite element analysis. The amount of hydrogen is high in smooth specimen and tends to concentrate in the vicinity of surface. The elongation and tensile strength decreased with the passage of charging time in 1.25Cr-0.5Mo and 2.25Cr-1Mo steels. The elongation increased and tensile strength decreased as strain rate increased. As a result of this study, it is supposed that 1.25Cr-0.5Mo steel is more sensitive than 2.25Cr-lMo steel in hydrogen embrittlement. Hydrogen embrittlement susceptibility of notched specimen after hydrogen charging is more remarkable than that of smooth specimen.

Effects of the Additives on Etching Characteristics of Aluminum Foil (첨가제에 의한 알루미늄박의 에칭특성변화)

  • Kim, Seong-Gap;Shin, Dong-Cheol;Jang, Jae-Myeong;Lee, Jong-Ho;Oh, Han-Jun;Chi, Chung-Su
    • Korean Journal of Materials Research
    • /
    • v.11 no.1
    • /
    • pp.48-54
    • /
    • 2001
  • The effects of additives in the HCI etching solution on etching behaviors of aluminum foil as dielectric film for electrolytic capacitors were investigated. The etch pits formed in 1M hydrochloric acid containing ethylene glycol as an additive contain more fine and homogeneous etch tunnels compared to those in 1 M hydrochloric acid only, which led to the increase in the effective internal surface area of aluminum foil. After anodizing of aluminum foil etched in etching solutions, the LCR meter results have shown that the capacitance of dielectric film etched in hydrochloric acid with ethylene glycol was increased remarkably compared to that etched in hydrochloric acid only.

  • PDF

Bone-like Apatite Morphology on Si-Zn-Mn-hydroxyapatite Coating on Ti-6Al-4V Alloy by Plasma Electrolytic Oxidation

  • Park, Min-Gyu;Choe, Han-Cheol
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.158-158
    • /
    • 2017
  • Titanium and its alloys have been used in the field dental and orthopedic implants because of their excellent mechanical properties and biocompatibility. Despite these attractive properties, their passive films were somewhat bioinert in nature so that sufficient adhesion of bone cells to implant surface was delayed after surgical treatment. Recently, plasma electrolyte oxidation (PEO) of titanium metal has attracted a great deal of attention is a comparatively convenient and effective technique and good adhesion to substrates and it enhances wear and corrosion resistances and produces thick, hard, and strong oxide coatings. Silicon(Si), Zinc(Zn), and Manganese(Mn) have a beneficial effect on bone. Si in particular has been found to be essential for normal bone and cartilage growth and development. And, Zn has been shown to be responsible for variations in body weight, bone length and bone biomechanical properties. Also, Mn influences regulation of bone remodeling because its low content in body is connected with the rise of the concentration of calcium, phosphates and phosphatase out of cells. The objective of this work was research on bone-like apatite morphology on Si-Zn-Mn-hydroxyapatite coating on Ti-6Al-4V alloy by plasma electrolytic oxidation. Anodized alloys were prepared at 280V voltage in the solution containing Si, Zn, and Mn ions. The surface characteristics of PEO treated Ti-6Al-4V alloy were investigated using XRD, FE-SEM, and EDS.

  • PDF

A Study on the standardize the characteristic evaluation of DC magnetron sputtered silver coatings for engineering purposes (D.C. magnetron sputter를 이용한 Ag layer 건식 도금층의 특성 평가 국제 표준화에 대한 연구)

  • Gyawali, Gobinda;Choi, Jinhyuk;Lim, Tae Kwan;Jung, Myoung Joon;Lee, Soo Wohn
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2015.11a
    • /
    • pp.249-249
    • /
    • 2015
  • Silver films have been of considerable interest for years due to their better performance relative to other metal films for engineering applications. A series of multi-layer silver coatings with different thickness (i.e. 0.3 um to 1.5 um) were prepared on Aluminium substrate containing copper undercoat by direct current (DC) magnetron sputtering method. For the comparative purpose, similar thickness silver coatings were prepared by electrolytic deposition method. Microstructural, morphological, and mechanical characteristics of the silver coatings were evaluated by means of scanning electron microscope (SEM), X-ray diffraction (XRD), Surface roughness test, microhardness test and nano-scratch test. From the results, it has been elucidated that the silver films prepared by DC magnetron sputtering method has superior properties in comparison to the wet coating method. On the other hand, DC magnetron sputtering method is relatively easier, faster, eco-friendly and more productive than the electrolytic deposition method that uses several kinds of hazardous chemicals for bath formulation. Therefore, a New Work Item Proposal (NWIP) for the test methods standardization of DC magnetron sputtered silver coatings has recently been proposed via KATS, Korea and a NP ballot is being progressed within a technical committee "ISO/TC107-metallic and other inorganic coating".

  • PDF

Characteristic of Hydrogen-oxygen Mixed Gas Power Conversion System (혼합수소발생기용 전력변환장치의 특성)

  • Mun, Sang-Pil;Lee, Hae-Su;Nakaoka, Mutsuo;Jeong, Jang-Geun;Kim, Chang-Il;Jo, Gil-Je;Kim, Sang-Don
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.323-326
    • /
    • 2007
  • In this paper, the basic experiment, electrolytic cell design and basic manufacturing have been made to interpret the characteristics of Hydrogen-Oxygen-Gas-Generator. As for the detailed matters, the data research on basic technology on Hydrogen-Oxygen-Gas and analysis on characteristics of Hydrogen-Oxygen-Gas from basic experiment. Also the experiment of characteristics and comparative evaluation between constant current source using SCR converter from existing method and constant current source using new phase shift PWM control method converter. As results when it has injected constant DC current, we has compared Gas quantities by variable ripple frequencies using phase shift PWM control method converter. Therefore, in linear region, it has not different Gas quantities by constant DC current and by phase shift PWM control method converter. Also, it has increased Gas quantities wilder linear region when put ripple frequency at saturation region. Through, Gas quantities and input rower, it has acquired higher input power per Gas quantities at put pulse current. Therefore, when designing converter or inverter for electrolysis, which has ripple current.

  • PDF

Development of Mixed Hydrogen Gas Generator Power Conversion System (Mixed Hydrogen Gas Generator용 전력변환장치 개발)

  • Jung, Jang-Gun;Mun, Sang-Pil;Cho, Gil-Je;Kim, Chang-Il
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.88-92
    • /
    • 2007
  • In this paper, the basic experiment, electrolytic cell design and basic manufacturing have been made to interpret the characteristics of Hydrogen-Oxygen-Gas-Generator. As for the detailed matters, the data research on basic technology on Hydrogen-Oxygen-Gas and analysis on characteristics of Hydrogen-Oxygen-Gas from basic experiment. Also the experiment of characteristics and comparative evaluation between constant current source using IGBT converter from existing method and constant current source using new phase shift PWM control method converter. As results when it has injected constant DC current, we has compared Gas quantities by variable ripple frequencies using phase shift PWM control method converter. Therefore, in linear region, it has not different Gas quantities by constant DC current and by phase shift PWM control method converter. Also, it has increased Gas quantities wilder linear region when put ripple frequency at saturation region. Through, Gas quantities and input power, it has acquired higher input power per Gas quantities at put pulse curren. Therefore, when designing converter or inverter for electrolysis, which has ripple current.

  • PDF

Comparative Study on the Grinded Surface Characteristics of Quartz Glass and SF-5 Glass using ELID(Electrolytic In-Process Dressing) Grinding (수정유리와 SF-5 유리의 ELID 연삭특성 비교)

  • 박상후;양동열;곽태수;오오모리히토시
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.94-97
    • /
    • 2003
  • A precise fabrication technology of glass is increasingly demanded fer the latest Industrial applications of spherical lenses. micro-optical components, laser applications and so on. Most of cases, the surface roughness of glass is required to be minute for improving the optical characteristics. Then. the machining characteristics of SF-5 glass and quarts glass were studied by using the ELID grinding process to get mirror surface and productivity compared with a general lapping process. A rotary type grinder with ELID generator was used to make the mirror surface of glass and a Mitutoyo surface tester and a nano-hardness tester were also used to measure the grinded surface or glass. As the results of experiments. they showed that the surface roughness(Ra) of SF-5 glass was under 7.8 nm and that of quartz glass was under 3.0 nm using the # 8000 grinder. So, the possibility of highly efficient and accurate surface for optical components can be achieved by the ELID grinding process.

  • PDF

The Effect of Forming Voltage on Electrical Characteristics in Aluminium Electrolytic Capacitors (알루미늄 전해 콘덴서에 있어서 화성전압이 전기적 특성에 미치는 영향)

  • Choo, J.S.;Kim, J.T.;Koo, J.Y.
    • Proceedings of the KIEE Conference
    • /
    • 1990.11a
    • /
    • pp.180-183
    • /
    • 1990
  • 알루미늄 전해 콘덴서에 있어서 유전체로 사용되는 $Al_2O_3$ 산화 피막의 두께와 형상이 콘덴서의 전기적 특성에 어떠한 영향을 미치는지 알아보기 위하여, 저압 16 V급과 중고압 200 V급으로 선정하여 화성전압을 변화시켜 시료 콘덴서를 제작한 후 전기적 제 특성을 측정하였다. 그 결과, 화성 전압이 높아질수록 산화 피막의 두께가 두껍게 형성되고 정전 용량은 감소하였으며, 유전 손실과 누설전류도 감소하였다. 또한, 장시간 수명시험을 수행한 결과 전기적 특성이 보다 안정되었음을 알았다.

  • PDF

A Study on the Characteristics of Compounding Electrolytic Machining in micro-cutting (전해복합에 의한 미세절삭가공 특성연구)

  • Son, M.K.;Son, S.M.;Ahn, J.H.
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.502-506
    • /
    • 2001
  • This paper presents a new method for cutting steel with a diamond tool using electrolysis. The electrolysis is adopted in the diamond cutting to prevent the high chemical activity between a diamond tool and an iron-based workpiece. The basic principle of the method is to oxdize a thin substrate of the workpiece by electrolysis ahead of the diamond tool which cuts the oxidized layer. A desired shape can be obtained by repeating this process. The cutting force is reduced because the diamond tool removes only the weakened material by electroysis. The reduction of the cutting force suppresses the excessive wear of the diamond tool. The oxidization penetrates several micrometers in depth along the previously formed shape. The corrosion rates depend on current density and make suggestions on the optimum cutting conditions.

  • PDF