• 제목/요약/키워드: Electrolysis Reactor

검색결과 54건 처리시간 0.022초

CFD 모사 기법을 이용한 전해반응기 내부 흐름 특성 분석 (Flow Characteristics Analyses within the Electrolysis Reactor using the CFD Simulation Technique)

  • 정종식;이승재;이재복
    • 상하수도학회지
    • /
    • 제30권6호
    • /
    • pp.745-753
    • /
    • 2016
  • The objective of this study was to investigate design factors of the electrolysis reactor through the CFD(computational fluid dynamics) simulation technique. Analyses of velocity vector, streamline, chloride ion concentration distribution showed differences in flow characteristics between the plate type electrode and the porous plate type electrode. In case of the porous plate type electrode, chlorine gas bubbles generated from the anode made upward density flow with relatively constant velocity vectors. Electrolysis effect was more expected with the porous plate type electrode from the distribution of chloride ion concentration. The upper part of the electrolysis reactor with the porous plate type electrode had comparatively low chloride concentration because chloride was converted to the chlorine gas formation. Decreasing the size and increasing total area of rectifying holes in the upper part of cathodes, and widening the area of the rectifying holes in the lower part of cathodes could improve the circulation flow and the efficiency of electrolysis reactor.

전기분해 반응조의 간접산화 효과가 하.폐수 재활용 시스템 설계에 미치는 영향 (Effect of Indirect Oxidation on the Design of Sewage/wastewater Reuse System with an Electrolysis Reactor)

  • 신춘환
    • 청정기술
    • /
    • 제15권2호
    • /
    • pp.116-121
    • /
    • 2009
  • Ti/$IrO_2$ 를 양극으로 SUS 316L 을 음극으로 사용한 전기분해 반응조에 간접산화조를 설치하여 간접산화 효과를 제시함으로써 하폐수 재활용 시스템의 설계에 미치는 영향을 고찰하였다. 전기분해 반응조의 운전조건은 극판 간격, 전류 밀도, 전해질 농도에 대한 영향을 조사하여 극판 간격 6 mm, 전류 밀도 1.0 $A/dm^2$ L, 전해질 농도 15%로 설정하였다. 산화에 의한 제거효율은 유기물은 COD로서 직접산화조에서 55%, 간접산화조에서 12.5${\sim}$15.0%의 추가 분해가 일어나고 있으며 T-N (전체 질소량), T-P(전체 인량)는 직접산화조에서 각각 88%, 75%의 제거효율을 나타내고 있으나 COD제거와는 달리 간접산화조의 추가 제거 효과는 거의 없는 것으로 판명되었다. 또한 COD, T-N, T-P의 제거는 2-5일의 반응초기에 일어나고 있기 때문에 전기 분해 반응조의 체류시간을 크게 설계할 필요는 없다는 결론을 얻을 수 있었다.

철 전기분해장치와 무산소/호기공정을 결합한 질소, 인제거 특성에 관한 연구 (A Characteristic of Nitrogen and Phosphorus Removal in Anoxic/Oxic Basins combined with Iron Electrolysis)

  • 김영규
    • 한국환경보건학회지
    • /
    • 제43권6호
    • /
    • pp.525-531
    • /
    • 2017
  • Objectives: The purpose of this experiment is to better understand the nitrogen and phosphorus removal ratio according to operating conditions in an iron electrolysis system consisting of an anoxic basin, aerobic basin, and iron precipitation apparatus. Methods: Iron electrolysis consists of an iron precipitation reactor composed of iron plates in oxic and anoxic basins. We studied the interrelation coefficient between T-N and T-P removal rates and F/M ratio, and the C/N ratio and BOD removal rate. Results: The F/M ratio and the T-N and T-P removal rate per unit area have interrelation coefficients of 0.362 and 0.603, respectively. The removal rate per MLVSS and the T-N and T-P removal rate per unit area have respective interrelation coefficients of 0.49 and 0.59. Conclusions: The removal rate of T-N and T-P increased with the increasing F/M ratio in the influent, and they also linearly increased in proportion to the C/N ratio of influent and BOD removal rate of the reactor.

철전기분해장치(FNR)에서 철판의 표면적이 인제거에 미친 영향에 관한 연구 (A Study on Phosphorus Removal Effects Per Iron Surface Area in FNR Process)

  • 김영규
    • 한국환경보건학회지
    • /
    • 제38권6호
    • /
    • pp.568-574
    • /
    • 2012
  • Objectives: The purpose of this experiment is to understand the phosphorus removal ratio effects of iron plates per unit of surface area through the iron electrolysis system, which consists of an anoxic basin, aerobic basin, and iron precipitation apparatus. Methods: Iron electrolysis, which uses an iron precipitation reactor in anoxic and oxic basins, consisted of iron plates with total areas of 400 $cm^2$, 300 $cm^2$ and 200 $cm^2$ respectively. The FNR process was operated with a hydraulic retention time and a sludge retention time of 12 hours and three days, respectively. Wastewater used in the experiments was prepared by dissolving $KH_2PO_4$ in influent water. Results: The iron plates 400 $cm^2$ (16.6 $mA/cm^2$), 300 $cm^2$ (13.3 $mA/cm^2$) and 200 $cm^2$ (7.3 $mA/cm^2$) in surface area in the phosphorus reactor had respective phosphorus of 2.4 mg/l, 2.7 mg/l and 3.2 mg/l in the effluent and phosphorus removal respective efficiencies of 90.3%, 89.1% and 87.1%. The effluent in the reactor, where the iron plate was not used, had relatively very low phosphorus removal efficiency showing phosphorus concentration of 15.3 mg/l and a phosphorus removal efficiency about 38.3%. Phosphorus removal per ferrous was 0.472 mgP/mgFe in the iron electrolysis system where the surface area of iron was low. Phosphorus pollution load per active surface area and the phosphorus removal efficiency had an interrelation of RE = -0.27LS + 89.0 (r = 0.85). Conclusion: With larger iron plate surface area, the elution of iron concentration and phosphorus removal efficiency was higher. The removal efficiency of phosphorus has decreased by increasing the initial phosphate concentration in the iron electrodes. This shows a tendency of decreasing phosphorus removal efficiency because of decreasing of iron deposition as the phosphorus pollution load per active surface area increases.

촉매성 산화물 전극 (DSA, Dimensionally Stable Anode)의 가속수명 테스트 방법과 장치에 관한 기초 연구 (A Basic Study on Accelerated Life Test Method and Device of DSA (Dimensionally Stable Anode) Electrode)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제27권6호
    • /
    • pp.467-475
    • /
    • 2018
  • The lifetime of the electrode is one of the most important factors on the stability of the electrode. Since the lifetime of the DSA (Dimensionally stable anode) electrode is long, an accelerated lifetime test is required to reduce the test time. Beacuse there is no basis or standard method for accelerated lifetime testing, many researchers use different methods. Therefore, there is a need for basis and methods for accelerated lifetime testing that other researchers can follow. We designed a reactor system for accelerated lifetime testing and planned specific methods. Reactor system was circulating batch reactor. Reactor volume and cooling water tank were 12.5 L and 100 L, respectively. Electrode size was $2cm{\times}3cm$ (real electrolysis area, $5cm^2$). In order to maintain the harsh conditions, accelerated lifetime test was carried out in a high current density ($0.6A/cm^2$) and low electrolyte concentration (NaCl, 0.068 mol/L). Maintaining a constant temperature was an important operation parameter for exact accelerated lifetime test. As the accelerated lifetime test progressed, the active component of electrode surface was consumed and desorption occurred. At the point of 5 V rise, corrosion of the surface of the base material(titanium) also started.

Lab-scale 고온전기분해 수소생산시스템의 장기운전 성능평가 (Long-Term Performance of Lab-Scale High Temperature Electrolysis(HTE) System for Hydrogen Production)

  • 최미화;최진혁;이태희;유영성;고재화
    • 한국수소및신에너지학회논문집
    • /
    • 제22권5호
    • /
    • pp.641-648
    • /
    • 2011
  • KEPRI (KEPCO Research Institute) designed and operated the lab-scale high temperature electrolysis (HTE) system for hydrogen production with $10{\times}10cm^2$ 5-cell stack at $750^{\circ}C$. The electrolysis cell consists of Ni-YSZ steam/hydrogen electrode, YSZ electrolyte and LSCF based perovskite as air side electrode. The active area of one cell is 92.16 $cm^2$. The hydrogen production system was operated for 2664 hours and the performance of electrolysis stack was measured by means of current variation with from 6 A to 28 A. The maximum hydrogen production rate and current efficiency was 47.33 NL/hr and 80.90% at 28 A, respectively. As the applied current increased, hydrogen production rate, current efficiency and the degradation rate of stack were increased respectively. From the result of stack performance, optimum operation current of this system was 24 A, considering current efficiencies and cell degradations.

FNR process를 이용한 하수처리장의 질소.인의 제거에 관한 연구 (A Study on Nitrogen and Phosphorus Removal in FNR Process)

  • 조일형;이내현;이승목;김영규
    • 한국환경과학회지
    • /
    • 제15권6호
    • /
    • pp.571-577
    • /
    • 2006
  • This study make a comparison between the phosphorus removal performance of FNR(Ferrous Nutrient Removal) process and A/O process by the laboratory experiments. For simultaneous removal of phosphorus, iron electrolysis was combined with oxic tank. Iron precipitation reactor on the electrochemical behaviors of phosphorus in the iron bed. The phosphorus removal in FNR process was more than A/O process. Iron salts produced by iron electrolysis might help to remove COD and nitrogen. And the demanded longer SRT is the more removes the removes COD, nitrogen, and phosphorus. Also, FNR process of sludge quantity more reduce than A/O process to input cohesive agents.

원자력을 이용한 수소생산기술 개발 동향 (Current Status of Nuclear Hydrogen Development)

  • 장종화
    • 에너지공학
    • /
    • 제15권2호
    • /
    • pp.127-137
    • /
    • 2006
  • 화학연료 사용으로 야기된 환경문제, 경제문제를 해결하기 위한 방안으로 수소경제가 추진되고 있다. 원자력을 이용한 대량수소생산은 수소경제를 뒷받침하기 위한 현실적인 방안이다. 본 논문에서는 원자력수소 생산에 사용할 초고온가스로의 특징과 개발현황, 초고온가스로로부터 발생하는 고온의 열을 이용한 수소생산방법 중 유력시 되는 기술로서 요오드-황 열화학법, 황산하이브리드법, 고온전기분해법의 기술개발 현황과 방향을 소개한다.

유동층전극 반응기를 이용한 폐수내의 중금속 회수 (Electrolytic recovery of metals from the plating rinse water with fluidized bed electrode reactor)

  • 이제근;전해수
    • 한국표면공학회지
    • /
    • 제17권1호
    • /
    • pp.1-6
    • /
    • 1984
  • The fluidized bed electrode reactor(FBER) with conducting particles has been made use of the removal of metals from dilute electroplating rinse water. The electrolysis was carried out under the conditions of diaphragm current density with 2~28A/$dm^2$ and bed expansion with 20~50%. Recirculating batch operations have been shown that the metal concentration dropped exponentially and may be taken down to 10 ppm. And then, the current efficiency at a concentration of 10 ppm copper was 37% under the conditions of 30% bed expansion and 6 A/$dm^2$, and at concentrated electrolyte (2000ppm copper) was over 80% in the range of 8~28A/$dm^2$ and 20~50% bed expansion. One of the technical possibilities of fluidized bed electrolysis is the separation of copper and nickel from a mixed solution of copper and nickel.

  • PDF

알루미늄의 전기분해를 이용한 오수 중의 인 제거 (Phosphorus Removal from Domestic Sewage by Electrolysis with Aluminium Electrodes)

  • 정경훈;최형일;정오진
    • 한국환경보건학회지
    • /
    • 제25권3호
    • /
    • pp.70-76
    • /
    • 1999
  • A laboratory experiment was performed to investigate the phosphorus removal using the activated sludge-electrolysis reactor which consisted of A$^2$/O system and aluminium electrodes as cathode and anode. In this system, the phosphorus was removed by aluminium ion, which was eluted from aluminiumelectrodes by electrolysis. In the batch experiments, when the current densities were 0.026, 0.052 and 0.08 A/dm$^2$, the phosphorus removal efficiencies for synthetic sewage were 66.4, 86.4 and 98.7% respectively. These results showed that the phosphorus removal efficiency increased with the increase of the current density. When the current values were 13, 26 and 40 mA respectively, the amounts of Al$^{3+}$ eluted from electrodes according to Faraday's law were 0.049, 0.07 and 0.12 g and Al/P mole ratio were 1.1, 2.0 and 3.41. In the continuous experiments, As hydraulic retention time(HRT) increased, COD and total nitrogen(T-N) removal efficiencies for domestic sewage increased. The average phosphorus removal rates of the activated sludge-electrolysis system were 97, 91, 80 and 80% at the HRT of 48, 24, 18 and 12 hours, respectively. Especially, the phosphorus removal rate in the activated sludge system with aluminium electrodes was higher than that in the system without aluminium electrodes.

  • PDF