• Title/Summary/Keyword: Electrokinetic (EK)

Search Result 44, Processing Time 0.025 seconds

Phenanthrene으로 오염된 Kaolinite에 Electrokinetic-Fenton 기법 적용시 묽은 산의 주입에 따른 효과

  • 김정환;김기년;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.318-321
    • /
    • 2003
  • This study explored the feasibility of applying Electrokinetic-Fenton process(EK-Fenton process) to remediation of contaminant sorbed on the soil possessed low-permeability. The addition of 0.01 N H$_2$SO$_4$ in the anode reservoir for the $H_2O$$_2$stabilization improved the stabilization of $H_2O$$_2$and the treatment effect of phenanthrene across the entire soil specimen. The use of $H_2O$$_2$and dilute acid as anode purging solution is a promising method treating of HOCs in low-permeability subsurface environments.

  • PDF

Effect of Electrolysis on Bacterial Activity in Electrokinetic Bioremediation (동전기 생물학적 복원에서 전기분해반응이 미생물 활성에 미치는 영향)

  • Kim, Sang-Joon;Park, Ji-Yeon;Lee, You-Jin;Yang, Ji-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.7
    • /
    • pp.764-769
    • /
    • 2006
  • In the electrokinetic(EK) process, oxygen production by electrolysis was proportional to current density. The dissolved oxygen (DO) concentration in anode tank and bioreactor increased with the circulation rate of electrolyte. The bacterial population in bioreactor rapidly increased by the supplement of current, but the DO concentration deceased by the increased bacterial oxygen consumption. From the results of EK bioremediation for pentadecane-contaminated soil, the bacterial population and removal efficiency at 1.88 $mA/cm^2$ were lower than those at 0.63 $mA/cm^2$. This is because the high oxygen production rate largely increased the production rate of organic acids, which reduced the electrolyte pH and bacterial activity. At 0.63 $mA/cm^2$, the highest bacterial population and removal efficiency could be obtained due to the appropriate oxygen production and small decrease in pH.

Removal of As, Cadmium and Lead in Sandy Soil with Sonification-Electrokinetic Remediation (초음파동전기기법을 이용한 비소, 카드뮴, 납으로 오염된 사질토 정화 연구)

  • Oh, SeungJin;Oh, Minah;Lee, Jai-Young
    • Journal of Soil and Groundwater Environment
    • /
    • v.18 no.7
    • /
    • pp.1-11
    • /
    • 2013
  • The actively soil pollution by the toxic heavy-metals like the arsenic, cadmium, lead due to the industrialization and economic activity. The uses the electrokinetic remediation of contaminated soil has many researches against the fine soil having a small size in the on going. However, it is the actual condition which the research result that is not effective due to the low surface charge of the particle and high permeability shows in the electrokinetic remediation in comparison with the fine soil in the case of the sandy soil in which the particle size is large. In this research, the electrokinetic remediation and ultrasonic wave fetch strategy is compound applied against the sandy soil polluted by the arsenic, cadmium, and lead removal efficiency of the sandy soil through the comparison with the existing electrokinetic remediation tries to be evaluated. First of all, desorption of contaminants in soil by ultrasonic extraction in the Pre-Test conducted to see desorption effective 5~15%. After that, By conducted Batch-Test results frequency output century 200 Khz, reaction time 30 min, contaminated soil used in experiment was 500 g. Removal efficiency of arsenic, cadmium, lead are 25.55%, 8.01%, 34.90%. But, As, Cd, Pb remediation efficiency less than 1% in EK1(control group).

Removal of Phenanthrene by Electrokinetic-Fenton Process in a 2-dimensional Soil System (동전기-펜턴 공정을 이용한 2차원 토양 정화장치에서의 phenanthrene 제거)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.11-17
    • /
    • 2005
  • Characteristics of phenanthrene removal in the Electrokinetic (EK)-Fenton process were investigated in a 2-dimensional test cell in a viewpoint of the effect of gravity and electrosmotic flow (EOF). When the constant voltage of 100 V was applied to this system, the current decreased from 1,000 to 290 mA after 28 days, because soil resistance increased due to the exhaustion of ions in soil by electroosmosis and electromigration. Accumulated EOF in two cathode reservoirs was 10.3 L and the EOF rate was kept constant for 28 days. At the end of operation, the concentration of phenanthrene was observed to be very low near the anode and increased in the cathode region because hydrogen peroxide was supplied from anode to cathode region following the direction of EOP. Additionally, the concentration of phenanthrene decreased at the bottom of the test cell because the electrolyte solution containing hydrogen peroxide was largely transported toward the bottom due to a low capillary action in the soil with high porosity. Average removal efficiency of phenanthrene by EK-Fenton process was 81.4% for 28 days. In-situ EK-Fenton process would overcome the limitations of conventional remediation technologies and effectively remediate the contaminated sites.

Effects of pH Control Methods on Removal Efficiency in Electrokinetic Bioremediation of Phenanthrene-contaminated Soil (Phenanthrene-오염토양의 동전기 생물학적 복원에서 pH 조절방법이 제거효율에 미치는 영향)

  • Kim, Sang-Joon;Park, Ji-Yeon;Lee, You-Jin;Yang, Ji-Won
    • KSBB Journal
    • /
    • v.21 no.3
    • /
    • pp.181-187
    • /
    • 2006
  • In this study, problems related with pH control in electrokinetic(EK) bioremediation of phenanthrene contaminated soil were observed, and the effects of pH control methods on the removal efficiency were investigated to search a further application strategy. In a preliminary experiment, it was found out by flask cultivation that a certain sulfate concentration was needed to degrade phenanthrene well using Sphingomonas sp. 3Y. However, when $MgSO_4$ was used as sulfate source in EK bioremediation, the bacterial activity reduced seriously due to the abrupt decrease of pHs in soil and bioreactor by the combination of magnesium and hydroxyl ions. When another strong buffering compound was used to control the pH problem, the good maintenance of the bacterial activity and pHs could be observed, but the removal efficiency decreased largely. When a low concentration of $MgSO_4$ was added, the removal efficiency decreased somewhat in spite of the good maintenance of neutral pHs. With the addition of NaOH as a neutralizing agent, the removal efficiency also decreased because of the increase of soil pH. Consequently the selection of electrolyte composition was a very important factor in EK bioremediation and some sulfate sources suitable for both bacterial activity and contaminant degradation should be investigated.

계면활성제와 동전기 기술을 이용한 오염토양정화에서 APG사용의 타당성에 관한 연구

  • 양지원;이유진;박지연;김상준
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.09a
    • /
    • pp.243-246
    • /
    • 2002
  • Surfactant-enhanced electrokinetic remediation is an emerging technology that can effectively remove hydrocarbons from low-permeability soils. In this study, the electrokinetic remediation using APG(alkyl polyglucoside) was conducted for the removal of phenanthrene from kaolinite. APG, which was an environmentally compatible and non-toxic surfactant, was used at concentrations of 5, 15, and 30g/1 to enhance the solubility of phenanthrene. Also an electrolyte solution was used for considering a relation between electrical potential gradient and removal efficiency of phenanthrene. When the electrolyte solution was used, it represented low electrical potential gradient, but the removal efficiency was lower than that of no electrolyte system. Removal efficiency of phenanthrene in EK process using surfactant solution depended on concentration of surfactant. Because surfactant increased the solubility and the mobility of phenanthrene, when surfactant concentration was high, high removal efficiency was observed.

  • PDF

Characteristic of Strength Increase in Clayey Soil by Electrokinetic Injection (동전기 주입에 의한 점성토의 강도증가 특성)

  • Kim, Ki-Nyun;Kim, Jong-Yun;Han, Sang-Jae;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.910-915
    • /
    • 2005
  • In this study a series of tests(bench scale test) are carried out for increasing in strength of clayey soil by EK-Injection method. In addition, the effects of strength increase in the treated sample are measured by operating the vane shear test device during 25 days at 5 days intervals in order to estimate the effect of ground improvement caused by diffusion. The test results show that the strength increase was developed approximately double to 7 times in comparison to initial shear strength, and outstanding strength increase was created as much as 7 times while injecting the sodium silicate and phosphoric acid in anolyte and catholyte. In addition, the measured shear strength with the influence of diffusion and reduction of water-content had a tendency to converge in constant value in proportion to elapsed time. As a result of this study, strength increment developed by the influence of EK-Injection and diffusion rather than the reduction of water-content were high as 1000% on average

  • PDF

Role of Electrode Reaction of Electrolyte in Electrokinetic-Fenton Process for Phenanthrene Removal (동전기-펜턴 공정에서 전해질의 전극반응이 처리효율에 미치는 영향)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.1
    • /
    • pp.7-13
    • /
    • 2006
  • The effects of electrolytes were investigated on the removal efficiency when several different electrolytes were used to change the electrode reaction in an electrokinetic (EK)-Fenton process to remediate phenanthrene-contaminated soil. Electrical potential gradient decreased initially due to the ion entrance into soil and then increased due to the ion extraction from soil under the electric field. Accumulated electroosmotic flow was $NaCl>KH_2PO_4>MgSO_4$ at the same concentration because the ionic strength of $MgSO_4$ was the highest and $Mg(OH)_2$ formed near the cathode reservoir plugged up soil pore to inhibit water flow. When hydrogen peroxide was contained in electrolyte solution, removal efficiency increased by Fenton reaction. When NaCl was used as an electrolyte compound, chlorine ($Cl_2$) was generated at the anode and dissolved to form hypochlorous acid (HClO), which increased phenanthrene removal. Therefore, the electrode reaction of electrolyte in the anode reservoir as well as its transport into soil should be considered to improve removal efficiency of EK-Fenton process.

The Remediation Characteristic of Soil Contaminated with Heavy Metal and Total Petroleum Hydrocarbon (TPH) by Enhanced Electrokinetic with Fenton Oxidation and Soil Flushing Method (펜톤 산화와 토양 세정이 보강된 동전기에 의한 중금속 및 총 석유 탄화수소(TPH)로 오염된 토양의 정화 특성)

  • Seo, Seok-Ju;Na, So-Jeong;Kim, Jung-Hwan;Park, Joo-Yang
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.885-893
    • /
    • 2014
  • This research reports the enhanced Electrokinetic (EK) with $H_2O_2$ and sodium dodecyl surfate (SDS), which are commonly used in Fenton oxidation and soil flushing method, in order to remediate soil contaminated with heavy metals and Total Petroleum Hydrocarbons (TPH) simultaneously. In addition, influences of property of soil and concentration of chemical solution were investigated through experiments of different types of soils and varying concentration of chemical reagents. The results indicated, in the experiments using artificially contaminated soil, the highest removal efficiency of heavy metals using 10% $H_2O_2$ and 20mM SDS as electrolytes. However, in the experiments using Yong-San soils (study area), remediation efficiency of heavy metals was decreased because high acid buffering capacity. Through experiment of 20% $H_2O_2$ and 40mM SDS, increased electric current influences the remediation of heavy metals due to decrease in the soil pH. In the experiments of Yong-San soils, the remediation efficiency of TPH was decreased compared with artificially spiked soils because high acid buffering capacity and organic carbon contents. Furthermore, the scavenger effect of SDS influenced TPH oxidation efficiency under the conditions of injected 40mM SDS in the soils. Therefore, the property of soil and concentration of chemical reagents cause the electroosmotic flow, soil pH, remediation efficiency of heavy metals and TPH.

Effect of ionic Strength of Electrolyte on Phenanthrene Removal in Electrokinetic-Fenton Process (동전기-펜턴 공정에서 phenanthrene 제거에 대한 전해질 이온세기의 영향)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.18-25
    • /
    • 2005
  • Characteristics of phenanthrene removal in an electrokinetic (EK)-Fenton process were investigated in a viewpoint of concentration and ionic strength of electrolytes. When three kinds of electrolytes (NaCl, $KH_2PO_4,\;and\;MgSO_4$) were used, the increase in electrolyte concentration caused the decrease of electrical potential gradient. The increase of electrical conductivity was due to the increase of ionic concentration in soil. The decrease of accumulated electroosmotic flow (EOF) with increase in electrolyte concentration was due to the decrease of zeta potential. The removal efficiency was in proportion to accumulated EOF which depended on ionic strength. Total energy expenditure without electrolyte was 10-30 times higher than its with 0.5 M electrolyte. The lower removal efficiency was caused by the lower energy expenditure with 0.5 M one. An effective EK-Fenton process was determined from considering the removal efficiency and the energy expenditure, simultaneously.