냉간 압연 공정에 의한 두께 $36{\mu}m$ 동극박 제조 공정 해석 (Fabrication of copper thin foils with 36 microns by cold rolling)

  • 이상호;김병민
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2007년도 춘계학술대회 논문집
    • /
    • pp.413-416
    • /
    • 2007
  • In general, by means of the electrodepositing technique, a copper foil sample was prepared with a high purity and a high density. But the mechanical properties of the electrodepositing copper foil was lower than it's the rolling copper foil. However, the production of copper foil with approximately 36 microns thick in rolling process was very difficult. This paper describes the outline of the high accuracy cold rolling in 6 high mill which was developed for the purpose of rolling very thin accurate gauge copper foil(36 micron thick), and give several rolling characteristic of 600 mm wide copper foil. a) Large strain can be accumulated pass by pass in industrial multi-pass rolling processing to overcome large critical strain for thickness accuracy through optimization of rolling schedule. b) Also, permissible tension for rolling 0.45 $\sim$ 0.036 mm thick copper strip stably in accordance with the each pass work had been established by FEM simulation results. c) During the plate rolling process, considerable values of the forces of material pressure on the tool occur. These pressures cause the elastic deformation of the roll, thus changing the shape of the deformation region. A numerical simulation of roll deflection during cold rolling is presented in the paper. d) The proposed pass schedule can roll very thin copper foil of 36 micron thickness to a tolerance of ${\pm}1$ microns. The validity of simulated results was verified into rolling experiments on the copper foil.

  • PDF

A Self-standing and Binder-free Electrodes Fabricated from Carbon Nanotubes and an Electrodeposited Current Collector Applied in Lithium-ion Batteries

  • Luais, Erwann;Mery, Adrien;Abou-Rjeily, John;Sakai, Joe;Tran-Van, Francois;Ghamouss, Fouad
    • Journal of Electrochemical Science and Technology
    • /
    • 제10권4호
    • /
    • pp.373-380
    • /
    • 2019
  • In this paper, we report the preparation of a flexible, self-standing and binder-free carbon nanotubes (CNTs) electrode with an electro-generated current collector. The copper current collector layer was electrodeposited on the backside of CNTs self-standing film obtained by a simple filtration process. The obtained CNTs-Cu assembly was used as a negative electrode in Li-ion batteries exhibiting good performance along with proving its applicability in flexible batteries.

Ruthenium Oxide Electrode Deposited on 3D Nanostructured-nickel Current Collector and Its Application to Supercapacitors

  • Ryu, Ilhwan;Kim, Green;Park, Dasom;Yim, Sanggyu
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.181.1-181.1
    • /
    • 2014
  • Supercapacitor is attracting growing attention for a promising energy conversion and storage device because of its desirable electrochemical properties such as rapid charge-discharge rate, high power density and long cycle life. Three-dimensional (3D) metal nanostructure has been widely studied since it can provide efficient charge transport along the 3D network in many device applications. In this work, we fabricated well-ordered 3D nickel (Ni) nanostructures using 3D-arrayed polystyrene nano-opal substrates. We also fabricated half-cell supercapacitors by electrodepositing $RuO_2$ onto these nanostructured Ni current collectors and investigated their morphological and electrochemical properties.

  • PDF

Prussian blue가 전착된 indium tin oxide 전극을 이용한 전기화학적 검출기 (An Electrochemical Detector Using Prussian Blue Electrodeposited Indium Tin Oxide Electrode)

  • 이인제;김주호;강치중;김용상
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권10호
    • /
    • pp.449-452
    • /
    • 2005
  • We fabricated an electrochemical detector (ECD) to catalyze redox reaction efficiently by electrodepositing Prussian blue (PB) on the indium tin oxide (ITO) electrode. Capillary electrophoresis (CE) and amperometric method were used. We investigated the PB surface properties by topography from atomic force microscopy (AFM). Also PB film thickness calibration with respect to deposition time and voltage was used to get better PB surFace. The PB thin film of dense and smooth surface could catalyze redox reaction efficiently. Comparing with CE-ECD microchip using bare-lTO electrode, proposed CE-ECD microchip using PB deposited electrode has shown better sensitivity by determining the detected peak current from the electropherograms while the concentration of tested analyzes was maintained the same. It is verified that detection limit can be lowered for 0.01 mM of dopamine and catechol respectively.

금속 나노와이어의 제조와 특성 (Metal nano-wire fabrication and properties)

  • 보보무로드 함라쿠로프;김인수
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2009년도 춘계학술대회 논문집
    • /
    • pp.432-434
    • /
    • 2009
  • Metal nano-wire arrays on Cu-coated seed layers were fabricated by aqueous solution method using sulfate bath at room temperature. The seed layers were coated on Anodic aluminum oxide (AAO) bottom substrates by electrochemical deposition technique, length and diameter of metal nano-wires were dominated by controlling the deposition parameters, such as deposition potential and time, electrolyte temperature. Anodic aluminum oxide (AAO) was used as a template to prepare highly ordered Ni, Fe, Co and Cu multilayer magnetic nano-wire arrays. This template was fabricated with two-step anodizing method, using dissimilar solutions for Al anodizing. The pore of anodic aluminum oxide templates were perfectly hexagonal arranged pore domains. The ordered Ni, Fe, Co and Cu systems nano-wire arrays were characterized by Field Emission Scanning Electron Microscopy (FE-SEM) and Vibrating Sample Magnetometer (VSM). The ordered Ni, Fe, Co and Cu systems nano-wires had different preferred orientation. In addition, these nano-wires showed different magnetization properties under the electrodepositing conditions.

  • PDF

Electrodeposition of Mn-Ni Oxide/PEDOT and Mn-Ni-Ru Oxide/PEDOT Films on Carbon Paper for Electro-osmotic Pump Electrode

  • Baek, Jaewook;Shin, Woonsup
    • Journal of Electrochemical Science and Technology
    • /
    • 제9권2호
    • /
    • pp.93-98
    • /
    • 2018
  • $MnO_2$, a metal oxide used as an electrode material in electrochemical capacitors (EDLCs), has been applied in binary oxide and conducting polymer hybrid electrodes to increase their stability and capacitance. We developed a method for electrodepositing Mn-Ni oxide/PANI, Mn-Ni oxide/PEDOT, and Mn-Ni-Ru oxide/PEDOT films on carbon paper in a single step using a mixed bath. Mn-Ni oxide/PEDOT and Mn-Ni-Ru oxide/PEDOT electrodes used in an electro-osmotic pump (EOP) have shown better efficiency compared to Mn-Ni oxide and Mn-Ni oxide/PANI electrodes through testing in water as a pumping solution. EOP using a Mn-Ni-Ru oxide/PEDOT electrode was also tested in a 0.5 mM $Li_2SO_4$ solution as a pumping solution to confirm the effect of the $Li^+$ insertion/de-insertion reaction of Ruthenium oxide on the EOP. Experimental results show that the flow rate increases with the increase in current in a 0.5 mM $Li_2SO_4$ solution compared to that obtained when water was used as a pumping solution.

백금 나노 도금입자가 산성 환경에서 탄소기판 부식에 미치는 영향 (Effects of Platinum Nano Electrodeposits on the Corrosion of Carbon Substrate in an Acidic Environment)

  • 최민호;박찬진
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2008년도 추계학술대회 초록집
    • /
    • pp.34-35
    • /
    • 2008
  • We investigated the effects of Pt nano electrodeposits on the corrosion of carbon substrate in an acidic solution. The electrodes for experiments were prepared by electrodepositing Pt on carbon substrate in a solution of 5 mM $H_2PtCl_6$ and 0.5 M $H_2SO_4$ using pulse deposition technique. In cyclic voltammograms for the carbon electrodes with and without Pt nano electrodeposits, total anodic current including both currents from oxygen evolution reaction and carbon corrosion increased abruptly above a critical potential. In addition, the critical potential of the carbon electrodes with Pt nano electrodeposits was lower than that of bare carbon electrode. This phenomenon was more prominent at $75^{\circ}C$ than $25^{\circ}C$. In potentiostatic experiments, the current transients and the corresponding power spectral density increased with increasing the applied potential for the electrodes. Furthermore, the current transients for the carbon electrodes with Pt nano electrodeposits were much higher than those for the bare carbon substrate. This indicates that the corrosion of carbon substrate can be highly accelerated by Pt nano electrodeposits.

  • PDF

코발트-철을 전해석출한 양극산화피막의 제작과 자기특성 (Preparations and Magnetic Properties of Aluminum Anodic Oxidized Films Electrodeposited Cobalt-Iron Alloys)

  • 강희우
    • 한국자기학회지
    • /
    • 제4권1호
    • /
    • pp.25-31
    • /
    • 1994
  • 코발트와 철의 이온을 혼합한 산성수용액 중에서, 알루미늄 양극산화피막에 전해석출 하여 제작된 자성막은, 코발트조성이 증가함에 따라 발크합금의 경우와 마찬가지로 상전이(phase shifting) 하였다. 입자직경이 $150\;{\AA}$의 시료의 경우 조성이 25-35 at% Co에서 큰 포화자화, 고항자력, 큰 자기이방성 에너지 및 우수한 각형비 등에 기인하는 큰 자기에너지 적($BH_{max}$)이 얻어진다. 그러나 입자직경이 $450\;{\AA}$의 경우에는, 코발트가 50-70 at% 일때 초기석출부 에 강자성체인 FeC가 아주 강하게 배향하므로, 입자의 큰 형상이방성(수직자기이방성)이 없어지고 면내 방향의 자기이방성을 나타낸다. 그리고 같은 조성에서 초기석출부를 제거하여 FeC의 영향을 없앨때, 주직자기이방성이 회복되었다.

  • PDF

Carbon Nanotube 전극과 효소반응기로 구성된 Amperometric Biosensor를 이용한 Biogenic Amines 검출 (Determination of Biogenic Amines using an Amperometric Biosensor with a Carbon Nanotube Electrode and Enzyme Reactor)

  • 김종원;전연희;김미라
    • 동아시아식생활학회지
    • /
    • 제20권5호
    • /
    • pp.735-742
    • /
    • 2010
  • 식품 중 잠재적 위험 물질로 작용할 수 있는 BAs의 신속 검출을 위하여 전기전도성이 우수하다고 알려진 MWCNTs의 개질, 작업 전극의 제작, 효소반응기 제작을 통해 바이오센서 시스템을 구성하고 hydrogen peroxide와 주요 BAs 물질에 대한 감응도를 측정하였다. MWCTS의 성질을 향상시키기 위해 아민기를 도입하였고, 이를 FT-IR 스펙트럼을 통해 확인하였다. 아민기를 도입한 MWCNTs를 GCE에 고착시키고 PB 막을 입힌 후 cyclic voltammetry 반응을 비교한 결과, PB/MWCNT-$NH_2$/GCE 전극이 GCE에 비해 산화 전류는 8배 이상, 전체 전류는 25배 이상의 높은 전류 흐름을 보였으며, 미세한 전류 흐름의 측정도 용이해진 것으로 나타났다. 또한, carrier buffer의 pH를 달리하여 제작된 전극의 감응 전류를 비교한 결과, pH 7.0에서 전류의 감응도가 가장 높게 측정되었다. 과산화수소를 주입하여 전극의 성능의 검증한 결과, $0.5 {\mu}M{\sim}100 {\mu}M$ 범위에서 선형관계를 보였으며, 검출 한계는 $0.5{\mu}M$로 측정되었다. Histamine 표준 용액 주입 시 $1{\mu}M{\sim}100{\mu}M$ 범위에서 선형 관계를 나타내었고, tyramine은 histamine에 비해 약 95%, 2-phenylethylamine과 tryptamine은 histamine에 비해 각각 75%, 70% 수준의 감응도를 이용하여 구성된 바이오센서 시스템이 낮은 검출 한계와 높은 수준의 반응 감도를 나타내어 BAs를 측정하는데 좋은 장치임이 확인되었다.