• 제목/요약/키워드: Electrode-lead contact

검색결과 17건 처리시간 0.026초

Normalized Contact Force to Minimize "Electrode-Lead" Resistance in a Nanodevice

  • Lee, Seung-Hoon;Bae, Jun;Lee, Seung Woo;Jang, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권8호
    • /
    • pp.2415-2418
    • /
    • 2014
  • In this report, the contact resistance between "electrode" and "lead" is investigated for reasonable measurements of samples' resistance in a polypyrrole (PPy) nanowire device. The sample's resistance, including "electrode-lead" contact resistance, shows a decrease as force applied to the interface increases. Moreover, the sample's resistance becomes reasonably similar to, or lower than, values calculated by resistivity of PPy reported in previous studies. The decrease of electrode-lead contact resistance by increasing the applying force was analyzed by using Holm theory: the general equation of relation between contact resistance ($R_H$) of two-metal thin films and contact force ($R_H{\propto}1/\sqrt{F}$). The present investigation can guide a reliable way to minimize electrode-lead contact resistance for reasonable characterization of nanomaterials in a microelectrode device; 80% of the maximum applying force to the junction without deformation of the apparatus shows reasonable values without experimental error.

Tetramethylthiuram monosulfide를 ionophore로 이용한 납 이온 선택성 poly(aniline) 고체 접촉 전극 (Lead Ion Selective Solid Contact Electrode based on Tetramethylthiuram monosulfide ionophore)

  • 한원식;박운석;권혜영;이영훈;홍태기
    • 한국응용과학기술학회지
    • /
    • 제30권2호
    • /
    • pp.356-361
    • /
    • 2013
  • Lead (II) ion selective poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore as a sulfur containing sensing material is successfully developed. The electrode exhibits good linear response of 25.6 mV / decade (at $20{\pm}0.2^{\circ}C$, r2=0.995) within the concentration range of $1.0{\times}10^{-1}{\sim}4.0{\times}10^{-7}$ M Pb (II). The composition of this electrode was Ionophore : PVC : dioctylphthalate : potassiumtetrakis(4-chlorophenyl)borate : Oleic acid = 5.0 : 20.0 : 25.0 : 4.0 : 5.0. When we consider the results of using different composition electrodes based on only one potassiumtetrakis(4-chlorophenyl)borate or Oleic acid liphophlic additive, poly(aniline) solid contact electrode based on Tetramethylthiuram monosulfide ionophore with potassiumtetrakis(4-chlorophenyl)borate and Oleic acid liphophlic additive had the best result in response characteristics. The electrode shows good selectivity for lead (II) ion in comparison with alkali, alkaline earth, transition and heavy metal ions. This electrode is suitable for use with aqueous solutions of pH 3.0 ~ 7.0 and their standard deviation in the measured emf differences was ${\pm}2.94$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-2}$ M and ${\pm}2.82$ mV at Tris buffered lead sample solution of $1.0{\times}10^{-3}$ M. Their stabilization time was less than 710 s. and response time was less than 16 s.

실리콘 태양전지용 Ag pastes 에서의 무연 프릿에 따른 Ag, Si간 접촉 형성 (Contact Formation Between Ag and Si With Lead-Free Frits in Ag Pastes For Si Solar Cells)

  • 김동선;황성진;김종우;이정기;김형순
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.61.2-61.2
    • /
    • 2010
  • Ag thick-film has usually been used for the front electrode of Si solar cells with the outstanding electrical properties. Ag paste consists of Ag powers, vehicles, frits and additives. Ag paste has broadly been screen-printed on the front side of Si wafer with the merits of low cost and simplicity. The optimal contact formation between Ag electrodes and Si wafer in the front electrode during a fast firing has been considered as the key factor for high efficiency. Although the content of frit in Ag pastes is less than 5wt%, it can profoundly influence the contact formation between Ag and Si under the fast firing. In this study, the effects of lead-free frits on the contacts between Ag and Si were studied with the thermal properties and compositions of various frits. Our experimental results showed that the electrical properties of cells were related to the interface structures between Ag and Si. It was found that current path of electrons from Si to Ag would be possible through the tunneling mechanism assisted by tens of nano-Ag recrystals on $n^+$ emitter as well as Ag recrystals penetrated into $n^+$ emitter layers. These preliminary studies will be helpful for designing the proper frits for the Ag pastes with considering the properties of various Si wafers.

  • PDF

스마트 헬스케어를 위한 심장활동 신호 검출용 접촉식 직물전극의 구조가 센싱 성능에 미치는 영향 (Effect of the Configuration of Contact Type Textile Electrode on the Performance of Heart Activity Signal Acquisition for Smart Healthcare)

  • 조현승;구혜란;양진희;이강휘;김상민;이정환;곽휘권;고윤수;오윤중;박서연;김신혜;이주현
    • 감성과학
    • /
    • 제21권4호
    • /
    • pp.63-76
    • /
    • 2018
  • 본 연구의 목적은 스마트 헬스케어를 위해 접촉식 직물전극의 구조가 심장활동 신호 획득에 미치는 영향을 연구하는 것이다. 본 연구에서는 심장활동 신호 측정을 위하여 전극의 크기와 구성방식을 조작한 6종의 접촉식 직물전극을 컴퓨터 자수 방식으로 구현하였고, 이를 가슴밴드에 부착하여 응용형 리드 II(modified Lead II) 방식으로 심장활동 신호를 검출하였다. 건강한 신체의 남성 4명을 대상으로 서서 정지한 자세에서 각 직물전극을 사용하여 심장활동 신호를 검출하였으며, 모든 유형의 전극에 걸쳐 4회씩 반복측정 하였다. 심장활동 신호의 수집을 위해 BIOPAC ECG100 장비를 사용하여 1 kHz로 샘플링하였으며, 검출된 원 신호를 대역통과 필터를 사용하여 필터링하였다. 직물전극의 구조에 따른 심장활동 신호 획득의 성능을 비교하기 위하여 신호의 파형과 크기를 파라미터로 하여 정성적 분석을 실시하였고, 각 전극을 통하여 획득된 심장활동 신호의 SPR(signal power ratio)을 산출함으로써 정량적 분석을 실시하였다. 산출된 SPR 값을 대상으로 하여 비모수 통계분석 방식의 차이검정과 사후검정을 실시함으로써 6개 전극의 구조에 따른 심장활동 신호 획득의 성능 차이를 구체적으로 분석하였다. 연구 결과 접촉식 직물전극의 구조에 따라 심장활동 신호의 품질에는 정성적, 정량적 측면에 걸쳐 모두 주요한 차이가 있는 것이 고찰되었다. 접촉식 직물전극의 구성 측면에 있어서는 입체전극이 평면전극에 비해 더 우수한 품질의 신호가 검출되는 것으로 나타났다. 한편 3가지 전극 크기에 따른 심장활동 신호 획득의 유의한 성능 차이는 발견되지 않았다. 이러한 결과는 심장활동 신호 획득을 위한 접촉식 직물전극 구조의 두 가지 요건 중 구성방식(평면/입체)이 웨어러블 헬스케어를 위한 심장활동 신호 획득의 성능에 주요한 영향을 미치는 것을 시사한다. 본 연구 결과를 기반으로 후속 연구에서는 직물전극이 일체형으로 통합된 의복형 플랫폼을 구현하고 성능 고도화 방안을 연구함으로써, 시공간의 제약 없이 고품질의 심장활동 모니터링이 가능한 스마트 의류 기술을 개발하고자 한다.

Surface Wear Monitoring with a Non-Vibrating Capacitance Probe

  • Zanoria, E.S.;Hamall, K.;Danyluk, S.;Zharin, A.L.
    • Tribology and Lubricants
    • /
    • 제11권5호
    • /
    • pp.40-46
    • /
    • 1995
  • This study concerns the design and development of the non-vibrating capacitance probe which could be used as a non-contact sensor for tribological wear. This device detects surface charge through temporal variation in the work function of a material. Experiments are performed to demonstrate the operation of the probe on a roating aluminum shaft. The reference electrode of the probe, made of lead, is placed adjacent (< 1.25-mm distance) to the shaft. Both surfaces which are electrically connected, form a capacitor. An artificial spatial variation in the work function is imposed on the shaft surface by coating a segment along the shaft circumference with a colloidal silver paint. As the shaft rotates, the reference electode senses changing contact potential difference with the shaft surface, owing to compositional variation. Temporal variation in the contact potential difference induces a current through the electrical connection. This current is amplified and converted to a voltage signal by an electoronic circuit with an operational amplifier. The magnitude of the signal decreases asymptotically with the electrode-shaft distance and increases linearly with the rotational frequency. These results are consistent with the theoretical model. Potential applications of the probe on wear monitoring are proposed.

Marmatite 鑛의 直接酸浸出에 關한 硏究 (第3報) Marmatite 鑛의 酸浸出과 黃化物의 電極電位에 關한 硏究 (Direct Acid Leaching of Zinc from Marmatite Ores 3 Acid Leaching of Marmatite Ores and the Electrode Potential Behavior of Sulfides)

  • 김재원
    • 대한화학회지
    • /
    • 제11권1호
    • /
    • pp.38-43
    • /
    • 1967
  • In order to explain the positive catalytic action of copper compound for the rate of leaching of zinc sulfide minerals, the electrode and redox potentials of both synthetic and natural sulfides were measured at various conditions of temperatures and pressures. The potentials of Chalcopyrite and copper sulfide were considerably higher than that of zinc sulfide, whereas lead sulfide and Galena had slightly lower potentials than that of zinc sulfide. At elevated temperatures and pressures, the same tendency was obtained. By means of comparing the calculated and measured values of potentials for sulfides, it was suggested that the electrode potentials in acid solution were generated by oxidation of sulfur ion. As a result, it was concluded that the catalytic action of copper compound in the leaching of synthetic zinc sulfide should be arised from the galvanic action between sulfides keeping intimate contact one another in which copper sulfide worked as cathodic and zinc sulfide as anodic part analogous to the metal corrosion under galvanic action.

  • PDF

Development of a Novel Noncontact ECG Electrode by MEMS Fabrication Process

  • Mathias, Dakurah Naangmenkpeong;Park, Jaesoon;Kim, Eungbo;Joung, Yeun-Ho
    • Transactions on Electrical and Electronic Materials
    • /
    • 제17권3호
    • /
    • pp.150-154
    • /
    • 2016
  • Contact electrodes pose threats like inflammation, metal poisoning, and allergic reaction to the user during long term ECG procedure. Therefore, we present a novel noncontact electrocardiographic electrode designed through microelectromechanical systems (MEMS) process. The proposed ECG electrode consists of small inner and large outer circular copper plates separated by thin insulator. The inner plate enables capacitive transduction of bio-potential variations on a subject’s chest into a voltage that can be processed by a signal processing board, whereas the outer plate shields the inner plate from environmental electromagnetic noise. The electrode lead wires are also coaxially designed to prevent cables from coupling to ground or electronic devices. A prototype ECG electrode has an area of about 2.324 cm2, is very flexible and does not require power to operate. The prototype ECG electrode could measure ECG at about 500 um distance from the subject’s chest.

직물 전극의 형상 특성이 자계 유도성 전도율 기반의 비접촉식 심장활동 센싱에 미치는 효과의 분석 (An Analysis on the Effect of the Shape Features of the Textile Electrode on the Non-contact Type of Sensing of Cardiac Activity Based on the Magnetic-induced Conductivity Priciple)

  • 지선옥;이영재;구혜란;강선아;박희정;김경섭;이주현;이정환
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.803-810
    • /
    • 2013
  • The purpose of this research is to analyze the effect of shape of the inductive textile electrode on the non-contact heart activity sensing, based on the magnetic-induced conductivity principle. Four types of the inductive textile electrodes were determined according to the combinations of the two shape features. A fiber-metal hybrid-typed conductive thread was developed and applied to materialization of the textile electrodes by embroidery method. The heart activity was extracted through the textile electrode sewn on a T-shirt. The experiments were implemented to constantly measure the heart activity for 20 seconds, in each case of 5 healthy male subjects. The heart activity signals acquired in each type of the inductive textile electrode were analyzed, 1)by drawing a comparison of morphology with those of ECG signal (LeadII), and 2)by calculation of the normalized mean and standard deviation of magnitude of the heart activity signals. The analysis resulted that the relatively better quality of signals were acquired in the 'square' types in the matter of whole shape, while the better results were obtained in 'donut' types in the matter of center hole. Accordingly, the relatively best quality of signals was obtained in the case of 'Square-Donut' type of the inductive textile electrode.

고효율 열전소재 2%Na-PbTe 의 소자화에 관한 연구 (Study on Metalizing 2% Na-PbTe for Thermoelectric Device)

  • 김훈;강찬영;황준필;김우철
    • 정보저장시스템학회논문집
    • /
    • 제10권2호
    • /
    • pp.32-38
    • /
    • 2014
  • Heat emission from the laser diode used in the optical disc drive and the defects from the increased temperature at the system have attracted attentions from the field of the information storage device. Thermoelectric refrigerator is one of the fine solutions to solve these thermal problems. The refrigeration performance of thermoelectric device is dependent on the thermoelectric material's figure-of-merit. Meanwhile, high electrical contact resistivity between metal electrode and p- and n-type thermoelectric materials in the device would lead increased total electrical resistance resulting in the degeneracy in performance. This paper represents the manufacturing process of the PbTe-based material which has one of the highest figure-of-merit at medium-high-temperature, ~ 600K to 900 K, and the nickel contact layer for reduced electrical contact resistance at once, and the results showing the decent contact structure and figure-of-merit even after the long-term operation environment.

Electroplating process for the chip component external electrode

  • Lee, Jun-Ho
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2000년도 추계학술발표회 초록집
    • /
    • pp.1-2
    • /
    • 2000
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the onventional rotating barrel, vibrational barrel(vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components. The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed thatbthe average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value. Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components. However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. 2H20 + e $\rightarrow$M/TEX> 20H + H2.. Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure there by resulting to bad plating condition.

  • PDF