• Title/Summary/Keyword: Electrode treatment

Search Result 697, Processing Time 0.031 seconds

Advanced Lake Water Treatment with Bipolar Packed Bed Electrode Cell(II) (3차원 전극(Bipolar Packed Bed Electrode)을 이용한 호소수 처리(II))

  • 장철현;박상우;최창수
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.355-360
    • /
    • 2002
  • This study was to analyze the right of wrong of gray-water treatment by applying BPBE electrode cell to the effluence water in the terminal disposal plant of sewage. The results were as follows : The best result was obtained with applied voltage 40V and detention time 6 minutes for the BPBE electrode cell which has the graphite-plate in main electro-de, packing coconut activated carbon. The elimination rate of COD of Al-plate was higher than that of graphite-plate in main electrode. The result of electrolysis for 3 hour in parallel circuit showed the using possibility of gray-water according to each elimination rate : COD 59%, T-N 69 %, T-P 69%. The BPBE electrode cell with the Al-plate in main electrode made the best effect for the elimination of algae in lake water and algae were not occurred in electrolytic water.

Influence of Manufacturing Conditions for the Life Time of the Boron-Doped Diamond Electrode in Wastewater Treatment (폐수처리용 붕소 도핑 다이아몬드 전극의 수명에 미치는 제조공정 변수의 영향)

  • Choi, Yong-Sun;Lee, Young-Ki;Kim, Jung-Yuel;Kim, Kyeong-Min;Lee, You-Kee
    • Korean Journal of Materials Research
    • /
    • v.27 no.3
    • /
    • pp.137-143
    • /
    • 2017
  • Boron-doped diamond (BDD) electrode has an extremely wide potential window in aqueous and non-aqueous electrolytes, very low and stable background current and high resistance to surface fouling due to weak adsorption. These features endow the BDD electrode with potentially wide electrochemical applications, in such areas as wastewater treatment, electrosynthesis and electrochemical sensors. In this study, the characteristics of the BDD electrode were examined by scanning electron microscopy (SEM) and evaluated by accelerated life test. The effects of manufacturing conditions on the BDD electrode were determined and remedies for negative effects were noted in order to improve the electrode lifetime in wastewater treatment. The lifetime of the BDD electrode was influenced by manufacturing conditions, such as surface roughness, seeding method and rate of introduction of gases into the reaction chamber. The results of this study showed that BDD electrodes manufactured using sanding media of different sizes resulted in the most effective electrode lifetime when the particle size of alumina used was from $75{\sim}106{\mu}m$ (#150). Ultrasonic treatment was found to be more effective than polishing treatment in the test of seeding processes. In addition to this, BDD electrodes manufactured by introducing gases at different rates resulted in the most effective electrode lifetime when the introduced gas had a composition of hydrogen gas 94.5 vol.% carbon source gas 1.6 vol.% and boron source gas 3.9 vol.%.

Electrochemical Treatment of Dyeing Wastewater using Insoluble Catalyst Electrode (불용성 촉매전극을 이용한 염색폐수의 전기화학적 처리)

  • Um, Myeong-Heon;Ha, Bum-Yong;Kang, Hak-Chul
    • Clean Technology
    • /
    • v.9 no.3
    • /
    • pp.133-144
    • /
    • 2003
  • In this study, Insoluble catalyst electrode for oxide systems were manufactured, by using of them, carried out experiments on electrolytic treatment of dyeing wastewater containing persistent organic compounds, and then made a comparative study of the efficiency of treatment for environmental pollutants and whether each of them is valuable of not as an electrode for soluble electrode(Fe, Al) and insoluble electrode(SUS, R.C.E; Replaced Catalyst Electrode) which were used in the electrolytic system. Besides, it was investigated the conditions for electrolytic treatment to find the maximum efficiency of electrolytic treatment. As the result of this study, by using of insoluble catalyst electrode for oxide can solved the stability of electrode that is one of the greatest problems in order to put to practical use of electrolysis process in the treatment of the sewage and wastewater and the result runs as follows; 1. The durability of insoluble catalyst electrode(R.C.E) can be verified the most favorable when the molar ratio of $RuO_2-SnO_2-IrO_2-TiO_2$(4 compounds system) is 70/20/5/5. 2. The efficiency of treatment was obtained a more than 90% goodness for CODMn and also a good results for T-N removal in the experimental conditions of the distance of electrode 5 mm, time of electrolysis 60 minutes, permissible voltage 10V, processing capacity $0.5{\ell}$.

  • PDF

The Effects of the Needle Electrode Electrical Stimulation in the Auricular Therapy on the smokers and non-smokers with Low Back Pain (외이에 적용한 침전극저주파치료가 흡연 및 비흡연 요통 환자에게 미치는 효과)

  • Min, Kyung-Ok;Kim, Soon-Hee;Park, Su-Jin
    • Journal of Korean Physical Therapy Science
    • /
    • v.9 no.1
    • /
    • pp.45-52
    • /
    • 2002
  • This study was intended to observe the relationship of pain alleviation between the group with needle electrode electrical stimulation applied on bach of head, lung, nasalis internae, shen-men, pharynx & larynx, and internal secretion which are the pants to regulate smoking and that, with no treatment of the kind among smokers and con-smokers with chronic low back pain. It also aimed to conduct a research of applying different treatment methods according to smoking, thus ultimately providing basic data needed by clinic therapists and to help achieve appropriate treatment effects considering the characteristics of each patient. The subject criteria were men who were in their 40's or 50's, smoking or non-smoking and came to the physical therapy of the hospital to cure the chronic low back pain which had lasted more than three months. The total 24 subjects were randomly divided into four groups according to smoking; the group of smokers with needle electrode electrical stimulation applied, that of smokers with no application of such treatment, that of non-smokers with the action of such treatment, and that of non-smokers with no application of such treatment Each group was measured in terms of four pain assessment methods of visual analogue scale(VAS), verbal rating scale(VRS), McGil pain questionnaire(MPQ), endorphin. And the results were as follows: 1. In terms of the effects of the needle electrode electrical stimulation in the auricular therapy on pain had by the smokers with low back pain, there was a statistical significance in VAS, VRS, and endorphin 1 between before and after the treatment. 2. In terms of the pain effects had by the smokers with low back pain when no needle electrode electrical stimulation in the auricular therapy was applied, there was a statistical significance in VRS and MPQ between before and after the treatment. 3. In terms of the effects of the needle electrode electrical stimulation in the auricular therapy on pain had by the non-smokers with low back pain, there was a statistical significance in VAS, VRS, and MPQ between before and after the treatment. In terms of the pain effects had by the non-smokers with low back pain when no needle electrode electrical stimulation in the auricular was applied, there was a statistical significance in VAS, VRS, and MPQ between before and after the treatment. 5. The smokers with low back pain were given the needle electrode electrical stimulation in the auricular therapy to see how it affected their pain. There was found pain reduction in number, but no statistical significance. 6. The subject suffering from low back pain were given the needle electrode electrical stimulation to see how it affected their pain according to smoking. There was found pain reduction in number, but no statistical significance. Based upon the results, it can be concluded that smokers with low back pain received the more effects of pain alleviation from the application of the needle electrode electrical stimulation in the auricular therapy compared to the rest of the groups who suffered from low back pain.

  • PDF

Effect of Thermal Treatment Temperature on Lifespan of Conductive Oxide Electrode

  • Yoo, Y.R.;Chang, H.Y.;Jang, S.G.;Nam, H.S.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.44-49
    • /
    • 2007
  • Dimensionally stable anodes have been widely used to cathodically protect the metallic materials in corrosive environments including concrete structure as the insoluble anode. Lifespan of the anode for concrete construction can be determined by NACE TM0294-94 method. Lifespan of conductive oxide electrode would be affected by thermal treatment condition in the process of sol-gel coatings. This work aims to evaluate the effect of thermal treatment temperature on the lifespan of the $RuO_{2}$ electrode. $450^{\circ}C$ treated conductive oxide electrode showed the excellent properties and its lifespan was evaluated to be over 88 years in 3% NaCl, 4% NaOH, and simulated pore water. This behavior was related to the formation of $RuO_{2}$.

동전기 정화 처리 효율 향상과 후처리 겸용 전극부(EPE) 개발

  • 김강호;한상재;김수삼
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.275-278
    • /
    • 2002
  • In this study, to increase removal efficiency of traditional electrokinetic treatment and to reduce contaminant load of wastewater that discharged through cathode compartment, enhanced electrode compartments were investigated. Hydroxide precipitation near the cathode electrode that encounter during traditional electrokinetic treatment were prevented by enhanced electrokinetic remediation test with newly invented electrode compartment. And heavy metal concentration in wastewater showed 0 ppm thus, additive post-treatment cost were not needed.

  • PDF

Effect of Microcurrent Stimulation at Hand Somatic Acupuncture Points on Experimental Pain Threshold (미세전류가 수부체성경혈점의 실험적 통증 역치에 미치는 영향)

  • Cho Jung-Sun;Chen Jae-Kyun;Park Rae-Joon
    • The Journal of Korean Physical Therapy
    • /
    • v.6 no.1
    • /
    • pp.85-93
    • /
    • 1994
  • The purposes of this study were 1) to examine the effects of microcurrent electrical neuromuscular stimulation 2) to compare surface electrode with needle electrode at somatic acupuncture points on experimental pain threshold measured at the distal end of the radius 3) to determine the changes in effect over time. A total of sixty healthy adult male and female subjects were assigned randomly to one of two experimental group or to a control group. Group 1(n=20) received MENS(Microcurrent Electrical Neuromuscular Stimulation) with surface electrode. Group 2(n=20) received HENS with needle electrode. Group 3(n=20) received no MENS. It measured experimental pain threshold at the wrist on pretreatment, 0 min after treatment. 15 min after treatment, 30 min after treatment in two experimental group. The results were as follows: 1. Experimental pain thresholds were higher in males than females(P<0.01). 2. Only the experimental group exhibited a significant increased in pain threshold after MENS treatment(P<0.05). 3. Surface electrode group increased significant pain threshold 0 min, 15 min after treatment, but greatly decrease 30 min after treatment. 4. Needle electrode group increased significant pain threshold 0 min, 15 min after treatment, but decrease 30 min after treatment. The results suggest that MENS applied to appropriate somatic acupuncture point can increase pain threshold. Further research is needed to assess the effects of greatly variety intensity of MENS of pain sufferes.

  • PDF

Assessment of gas production and electrochemical factors for fracturing flow-back fluid treatment in Guangyuan oilfield

  • Liu, Yang;Chen, Wu;Zhang, Shanhui;Shi, Dongpo;Zhu, Mijia
    • Environmental Engineering Research
    • /
    • v.24 no.3
    • /
    • pp.521-528
    • /
    • 2019
  • Electrochemical method was used for the fracturing flow-back fluid treatment in Guangyuan oilfield. After performing electrolysis, we found that the amount of $H_2$ gas produced by electrode was closely related to the combination mode of electrodes and electrode materials. Using an aluminium electrode resulted in a large $H_2$ production of each electrode combination, whereas inert anode and cathode materials resulted in low $H_2$ production. Then, the relationship between the gas production of $H_2$ and the treatment efficiency of fracturing flow-back fluid in Guangyuan oilfield was studied. Results showed that the turbidity removal and decolourisation rates of fracturing flow-back fluid were high when $H_2$ production was high. If the $H_2$ production of inert electrode was large, the energy consumption of this inert electrode was also high. However, energy consumption when an aluminium anode material was used was lower than that when the inert electrode was used, whereas the corresponding electrode combination production of $H_2$ was larger than that of the inert electrode combination. When the inert electrode was used as anode, the gas production type was mainly $O_2$, and $Cl_2$ was also produced and dissolved in water to form $ClO^-$. $H_2$ production at the cathode was reduced because $ClO^-$ obtained electrons.

Treatment of Heavy Metal Wastewater Bed Electrode Reactor by a Fluidized 1. Distribution of Local Mass Transfer Coefficients on the Current Feeder (유동층 전극반응기를 이용한 중금속폐수의 처리에 관한 연구 1. 전류공급원에서의 국부물질전달계수의 분포)

  • 황영기;정은혁
    • Journal of Environmental Science International
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 1997
  • Varing the flow velocity of solution and particle diameter, the mass transfer coefficient of the local electrode on current feeder has been measured in an empty flow reactor, an inert fluidized bed electrode reactor, and an active fluidized bed electrode reactor. It had its maximium value when the bed porosity was 0.6 to 0.65 and decreased with in- creasing the height of local electrode. The mass transfer coefficient was found to be high especially when higher particle was fluidized. Electrochemical deposition of copper dissolved in the synthesized wastewater has been performed in the active fluidized bed electrode reactor. The deduction rate was higher than 90% and the residual concentration of copper decreased to less than 5ppm.

  • PDF

Surface treatment of silver-paste electrode by atmospheric-pressure plasma-jet (대기압 플라즈마 제트를 이용한 실버페이스트 전극의 표면처리)

  • Sheik Abdur Rahman;Shenawar Ali Khan;Yunsook Yang;Woo Young Kim
    • Journal of the Korean Applied Science and Technology
    • /
    • v.40 no.1
    • /
    • pp.71-80
    • /
    • 2023
  • Silver paste is a valuable electrode material for electronic device applications because it is easy to handle with relatively low heat treatment. This study treated the electrode surface using an atmospheric-pressure plasma jet on the silver-paste electrode. This plasma jet was generated in an argon atmosphere using a high voltage of 5.5 to 6.5 kV with an operating frequency of 11.5 kHz. Plasma-jet may be more beneficial to the printing process by performing it at atmospheric pressure. The electrode surface becomes hydrophilic quickly and contact angle variation is observed on the electrode surface as a function of plasma treatment time, applied voltage, and gas flow rate. Also, there was no deviation in the contact angle after the plasma treatment in the large-area sample, that means a uniform result could be obtained regardless of the substrate size. The outcomes of this study are expected to be very useful in forming a stacked structure in the manufacture of large-area electronic devices and future applications.