• Title/Summary/Keyword: Electrode pattern design

Search Result 40, Processing Time 0.024 seconds

Output Voltage Characteristics of HVDC Electric Field Mill Sensor for Different Speed Variables of Rotating Electrode

  • Kim, Young Sun;Park, Jae Jun
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.5
    • /
    • pp.2001-2006
    • /
    • 2017
  • This paper explains the effects of the weak signal of a rotating-type electric field mill sensor fabricated for measuring the intensity of the electric field generated by high-voltage direct current (HVDC) power transmission lines. The fabricated field mill consists of two isolated electrode vanes, a motor driver, and a ground part. The sensor plate is exposed to and shielded from the electric field by means of a rotary shutter consisting of a motor-driven mechanically complementary rotor/stator pair. When the uncharged sensor plate is exposed to an electric field, it becomes charged. The rotating electrode consists of several conductive vanes and is connected to the ground part, so that it is shielded. Determining the appropriate design variables such as the speed of the vane, its shape, and the distance between the two electrodes, is essential for ensuring optimal performance. By varying the speed, the weak signal characteristics which is used to signal processing and calibration experiment are quite different. Each weak signal pattern was analyzed along with the output voltage characteristics, in order to be able to determine the intensity of the electric field generated by HVDC power transmission lines with accuracy.

Improvement of Stimulus Pattern and Design of Discrimination System for Coincident ratio Elevation with Traditional Meridians (고전경락과의 부합율 향상을 위한 경혈자극방식의 개선 및 식별시스템의 설계)

  • Lee, Yong-Heum;Ko, Su-Bok;Jeong, Dong-Myong
    • Journal of IKEEE
    • /
    • v.7 no.1 s.12
    • /
    • pp.22-31
    • /
    • 2003
  • Conventional stimulus patterns have used DC for discrimination of acupoint and meridian which is the basic object of diagnosis and medical treatment in oriental medicine. Those discriminate conduction points by stimulation on body skin with DC. But, it is insufficient to reliability in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper has extracted the optimal parameter of frequency and waveform in order to improve conventional pattern, and proposed the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, We proposes algorithm which is able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It can decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. We have compared the performance of system applying the extracted optimal parameter and algorithm. We have compared discrimination, coincident ratio of both conduction point and traditional acupoints by acupoint stimulation pattern. In the results, we confirmed reliability of SPAC stimulus pattern.

  • PDF

Flat Speaker Design by Optimization of Plane Actuator (평판 작동기의 최적화를 통한 평면 스피커 설계)

  • Kim Seung Jo;Hwang Joon-Seok
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.237-242
    • /
    • 1999
  • In this study, a design method using plane actuator is developed to make new speaker system, whose shape is much thinner than that of conventional loudspeaker. Piezofilm(PVDF) is used as plane actuator of flat speaker. To avoid the distortion of sound radiated from flat speaker, the frequency response of radiated sound to be flat is taken as the design objective. The electrode pattern and orientation angle of piezofilm actuator is optimized to satisfy the design objective. The formulation is based on the coupled finite element and boundary element method. Genetic algorithm is used in the optimization process, which is useful in the optimization of discrete design variables. Frequency response with optimized piezofilm actuator is made flat enough to satisfy the design objective. For the enhancement of sound power, double-layered piezofilm actuators are also considered. The sound power with double-layered actuator becomes larger than that with single-layered actuator as expected.

  • PDF

Design of Loudspeaker using Composite Plate and Piezofilm Actuator (복합재료 평판과 압전필름 작동기를 이용한 저음용 평판 스피커 설계)

  • 황준석;김승조
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.124-129
    • /
    • 1999
  • In this study, a design method for the flat sound radiator is developed to make new sound radiator system, whose shape is much thinner than that of conventional loudspeaker. Piezofilm (PVDF) is used as actuators of flat sound radiator. To avoid the distortion of sound radiated from flat sound radiator, the frequency response of radiated sound to be flat is taken as the design objective. The electrode pattern and orientation angle of piezofilm actuator is optimized to satisfy the design objective. The formulation is based on the coupled finite element and boundary element method. Genetic algorithm is used in the optimization process, which is useful in the optimization of discrete design variables. Frequency response with optimized piezofilm actuator is made flat enough to satify the design objective. For the enhancement of sound power, double-layered piezofilm actuators are also considered. The sound power with double-layered actuator becomes larger than that with single-layered actuator as expected.

  • PDF

Study on the Effect of the Operation Voltage according to the Reverse Twist for the fringe Field Switching (FFS) Mode (FFS 모드에서 Reverse Twist가 구동전압에 미치는 영향에 관한 연구)

  • Kim, Mi-Sook;Jung, Yeon-Hak;Seen, Seung-Min;Kim, Hyang-Yul;Kim, Seo-Yoon;Lim, Young-Jin;Lee, Seung-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.11
    • /
    • pp.1033-1037
    • /
    • 2005
  • We have studied on the effect of the operation voltage according to the reverse twist for the different fringe field switching (FFS) structure. The FFS structure with a vertically patterned edge of the pixel electrode (VPP) has lower operation voltage comparing to the one with a horizontally patterned edge of the pixel electrode (HPP). The reason is like that the number of the pattern of the pixel edge for the VPP structure is one third comparing with the HPP structure and thus, there is small reverse twist area for the VPP structure. Actually, the reverse twist disturbs the twist of LC near adjacent active area, result that LCs near there have the unstable dynamics. That is, the operation voltage increases as the reverse twist area increases. Therefore, it is very important to design pixel electrode with a small reverse twist region for the FFS mode.

Development and Usability Test of Baby Vest Prototypes with a Body Temperature Sensing Function

  • Yi, Kyong-Hwa;Song, Hayoung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.3
    • /
    • pp.427-440
    • /
    • 2020
  • This study developed a vest prototype capable of monitoring body temperature using textile electrodes to prevent the sudden death of babies as well as to determine the quality of developed products by evaluating usability with commercial products. Based on the results of the 7th Size Korea Project, a basic pattern for a vest prototype was drafted by applying the average size of two-year-old Korean babies. Two prototypes were the detachable (VEST I) and integrated textile electrodes vest type (VEST II), which followed the same design. The materials were 100% cotton single jersey (SJ) and double jersey (DJ). Six experts evaluated the usability of the developed vests (VEST I & VEST II) and commercial product (VEST M). The single-layer woven textile electrode appeared to have a slightly higher conductivity than the double-layer one. There was no statistical difference in the body temperature sensing function between VEST I and VEST II. Finally, the superiority of the VEST I was verified through a comparison with commercial products (VEST M). The usability test suggested that a wearable smart clothing system of the integrated conductive textile could be further commercialized for bio-monitor applications in Ubiquitous-health care.

Development of Bib Pants Design and Pattern for Cycling Smart Wear (사이클링 스마트웨어 제작을 위한 빕 팬츠 디자인 및 패턴 개발)

  • Yunyoung, Kim;Byeongha, Ryu;Woojae, Lee;Kikwang, Lee;Rira, Kim
    • Journal of Fashion Business
    • /
    • v.26 no.5
    • /
    • pp.91-104
    • /
    • 2022
  • In this study, a cycling smart wear for measuring cycling posture and motion was developed using a three-dimensional motion analysis camera and an IMU inertial sensor. Results were compared according to parts to derive the optimal smart device attachment location, enabling correct posture measurement and cycle motion analysis to design a pattern. Conclusions were as follows: 1) 'S-T8' > 'S-T10' > 'S-L4' was the most significant area for each lumbar spine using a 3D motion analysis system with representative posture change (90°, 60°, 30°) to derive incisions and size specifications; 2) the part with the smallest relative angle change among significant section reference points during pattern design was applied as a reference point for attaching a cycling smart device to secure detachable safety of the device. Optimal locations for attaching the cycling device were the "S-L4" hip bone (Sacrum) and lumbar spine No. 4 (Lumbar 4th); 3) the most suitable sensor attachment location for monitoring knee induction-abduction was the anatomical location of the rectus femoris; 4) a cycling smart wear pattern was developed without incision in the part where the sensor and electrode passed. The wearing was confirmed with 3D CLO. This study aims to provide basic research on exercise analysis smart wear, to expand the smart cycling area that could only be realized with smart devices and smart watches attached to current cycles, and to provide an opportunity to commercialize it as cycling smart wear.

Design and Fabrication of Flexible OTFTs by using Nanocantact Printing Process (미세접촉프린팅 공정을 이용한 유연성 유기박막소자(OTFT)설계 및 제작)

  • Jo Jeong-Dai;Kim Kwang-Young;Lee Eung-Sug;Choi Byung-Oh;Esashi Masayoshi
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.10a
    • /
    • pp.506-508
    • /
    • 2005
  • In general, organic TFTs are comprised of four components: gate electrode, gate dielectric, organic active semiconductor layer, and source and drain contacts. The TFT current, in turn, is typically determined by channel length and width, carrier field effect mobility, gate dielectric thickness and permittivity, contact resistance, and biasing conditions. More recently, a number of techniques and processes have been introduced to the fabrication of OTFT circuits and displays that aim specifically at reduced fabrication cost. These include microcontact printing for the patterning of metals and dielectrics, the use of photochemically patterned insulating and conducting films, and inkjet printing for the selective deposition of contacts and interconnect pattern. In the fabrication of organic TFTs, microcontact printing has been used to pattern gate electrodes, gate dielectrics, and source and drain contacts with sufficient yield to allow the fabrication of transistors. We were fabricated a pentacene OTFTs on flexible PEN film. Au/Cr was used for the gate electrode, parylene-c was deposited as the gate dielectric, and Au/Cr was chosen for the source and drain contacts; were all deposited by ion-beam sputtering and patterned by microcontact printing and lift-off process. Prior to the deposition of the organic active layer, the gate dielectric surface was treated with octadecyltrichlorosilane(OTS) from the vapor phase. To complete the device, pentacene was deposited by thermal evaporation and patterned using a parylene-c layer. The device was shown that the carrier field effect mobility, the threshold voltage, the subthreshold slope, and the on/off current ratio were improved.

  • PDF

Fabrication of Transparent Electrode Film for Organic Photovoltaic using Ag grid and Conductive Polymer (Ag grid와 전도성 고분자를 이용한 인쇄기반 OPV용 투명전극 형성)

  • Yu, Jongsu;Kim, Jungsu;Yoon, Sungman;Kim, Dongsoo;Kim, Dojin;Jo, Jeongdai
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.116.1-116.1
    • /
    • 2011
  • Materials with a combination of high electrical conductivity and optical transparency are important components of many electronic and optoelectronic devices such as liquid crystal displays, solar cells, and light emitting diodes. In this study, to fabricate a low-resistance and high optical transparent electrode film for organic photovoltaic, the following steps were performed: the design and manufacture of an electroforming stamp mold, the fabrication of thermal roll imprinted (TRI) poly-carbonate (PC) patterned films, the manufacture of high-conductivity and low-resistance Ag paste which was filled into patterned PC film using a doctor blade process and then coated with a thin film layer of conductive polymer by a spin coating process. As a result of these imprinting processes the PC films obtained a line width of $10{\pm}0.5{\mu}m$, a channel length of $500{\pm}2{\mu}m$, and a pattern depth of $7.34{\pm}0.5{\mu}m$. After the Ag paste was used to fill part of the patterned film with conductive polymer coating, the following parameters were obtained: a sheet resistance of $9.65{\Omega}$/sq, optical transparency values were 83.69 % at a wavelength of 550 nm.

  • PDF

Extraction of Parameters for Acupoint Discrimination and Design of discrimination system (경혈식별을 위한 파라메터 추출 및 식별시스템의 설계)

  • 이용흠;박창규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.5 no.1
    • /
    • pp.89-101
    • /
    • 2001
  • The conventional pattern-methods for discrimination of acupoint, meridian line which is the basic object of diagnosis and medical treatment in oriental medicine is discriminated the conduction point by the stimulation in body skin with DC. But, it is not sufficient to truth in discrimination ratio, coincident ratio, body effect, reproductivity. Therefore, this paper is extracting the optimal parameter of frequency and waveform in order to improve the conventional pattern, and proposing the SPAC(Single Power Alternative Current) stimulus pattern applying that. Also, this algorithm proposes to be able to discriminate with low pressure of the electrode by displaying in the level meter both the absolution and relation value of the skin current. It is able to decrease pain and body effect by electrode pressure and discriminate acupoint regardless of skin current in difficult discrimination spot. It is compared the performance of system applying the extracted optimal parameter and algorithm, and it is confirmed that there is difference in discrimination parameter of acupoint reacted to the individual and the meridian. It is compared that discrimination, coincident ratio of the traditional acupoints as the acupoint stimulation pattern. It is confirmed truth of optimal parameter and discrimination algorithm. Keyword: Meridian, Discrimination, Coincident, Body effect, Reproductivity, SPAC, Optimal parameter.

  • PDF