Electrical Insulation Characteristics of HTS SMES (고온초전도 SMES의 절연특성)

  • Cheon Hyeon-Gweon;Choi Jae-Hyeong;Kwag Dong-Soon;Kim Hae-Jong;Seong Ki-Chul;Yun Mun-Soo;Kim Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.6
    • /
    • pp.574-578
    • /
    • 2006
  • Toward the practical applications, on operation of conduction-cooled HTS SMES at temperatures well below 77 K should be investigated, in order to take advantage of a greater critical current density of HTS and considerably reduce the size and weight of the system. Recently, research and development concerning application of the conduction-cooled HTS SMES that is easily movement are actively progressing in Korea. Electrical insulation under cryogenic temperature is a key and an important element in the application of this apparatus. Using multi wrapped copper by Polyimide film for HTS SMES, the breakdown characteristics of models for turn-to-turn, that is surface contact model, were investigated under ac and impulse voltage at 77 K. A material that is Polyimide film (Kapton) 0.025 mm thickness is used for multi wrapping of the electrode. Statistical analysis of the results using Weibull distribution to examine the wrapping number effects on breakdown voltage under at and impulse voltage in $LN_2$ was carried.

Earth Analysis Method for Installation of Equipment for Moving Pesticide Spraying System (농약살포시스템 이동을 위한 기구물 설치를 위한 대지 분석방법)

  • Boo, Chang-Jin
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.1152-1157
    • /
    • 2018
  • In this paper, we try to solve the difficulties of the location of the structure for the movement of the wire - based pesticide spraying equipment designed for field farming. To do this, we apply earth resistivity measurement method and analysis technique which can indirectly grasp the earth structure. Electrodes are installed on the field in a selected farming area, and multi-switches built in the control board are driven to automatically acquire ground resistivity data. Then, the optimal point suitable for the actual structure installation is selected through the site analysis using the 2D image restoration algorithm.

Preparation and Electrochemical Behaviors of Petal-like Nickel Cobaltite/Reduced Graphene Oxide Composites for Supercapacitor Electrodes

  • Kim, Jeonghyun;Park, Soo-Jin;Kim, Seok
    • Applied Chemistry for Engineering
    • /
    • v.30 no.3
    • /
    • pp.324-330
    • /
    • 2019
  • Petal-like nickel cobaltite ($NiCo_2O_4$)/reduced graphene oxide (rGO) composites with different $rGO-to-NiCo_2O_4$ weight ratios were synthesized using a simple hydrothermal method and subsequent thermal treatment. In the $NiCo_2O_4/rGO$ composite, the $NiCo_2O_4$ 3-dimensional nanomaterials contributed to the improvement of electrochemical properties of the final composite material by preventing the restacking of the rGO sheet and securing ion movement passages. The composite structure was examined by field-emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), and Fourier-transform infrared (FT-IR) spectroscopy. The FE-SEM and TEM images showed that petal-like $NiCo_2O_4$ was supported on the rGO surface. Cyclic voltammetry (CV), galvanostatic charge-discharge (GCD), and electrochemical impedance spectroscopy (EIS) were used for the electrochemical analysis of composites. Among the prepared composites, $0.075g\;rGO/NiCo_2O_4$ composite showed the highest specific capacitance of $1,755Fg^{-1}$ at a current density of $2Ag^{-1}$. The cycle performance and rate capability of the composite material were higher than those of using the single $NiCo_2O_4$ material. These nano-structured composites could be regarded as valuable electrode materials for supercapacitors that require superior performance.

Conduction Mechanism of Charge Carriers in Electrodes and Design Factors for the Improvement of Charge Conduction in Li-ion Batteries

  • Akhtar, Sophia;Lee, Wontae;Kim, Minji;Park, Min-Sik;Yoon, Won-Sub
    • Journal of Electrochemical Science and Technology
    • /
    • v.12 no.1
    • /
    • pp.1-20
    • /
    • 2021
  • In-depth knowledge of electrode processes is crucial for determining the electrochemical performance of lithium-ion batteries (LIBs). In particular, the conduction mechanisms of charged species in the electrodes, such as lithium ions (Li+) and electrons, are directly correlated with the performance of the battery because the overall reaction is dependent on the charge transport behavior in the electrodes. Therefore, it is necessary to understand the different electrochemical processes occurring in electrodes in order to elucidate the charge conduction phenomenon. Thus, it is essential to conduct fundamental studies on electrochemical processes to resolve the technical challenges and issues arising during the ionic and electronic conduction. Furthermore, it is also necessary to understand the transport of charged species as well as the predominant factors affecting their transport in electrodes. Based on such in-depth studies, potential approaches can be introduced to enhance the mobility of charged entities, thereby achieving superior battery performances. A clear understanding of the conduction mechanism inside electrodes can help overcome challenges associated with the rapid movement of charged species and provide a practical guideline for the development of advanced materials suitable for high-performance LIBs.

Preliminary Report of Gamma Knife Radiosurgery for the Movement Disorders (운동성 장애에 대한 감마나이프 시술의 초기경험)

  • Hong, Joon Ki;Kim, Moo Seong;Lee, Sun Il;Jung, Yong Tae;Kim, Soo Chun;Sim, Jae Hong
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.8
    • /
    • pp.1024-1029
    • /
    • 2000
  • Objectives : With recent improvements in neuroimaging and the development of third and fourth-generation radiosurgical dose-planning soft ware, came a renewed interest in using radiosurgery for the treatment of movement disorders. Radiosurgery involves no opening of the cranium and no incisions, eliminating both the risk of hemorrhage from passing an electrode to the depths of meningitis from operative infection. It is for these reasons stereotactic radiosurgical treatment of movement disorders has value in a small subgroup of patients. The authors report four cases of Parkinson's disease and one case of dystonia that were treated by Gamma knife. Methods : Radiosurgical nucleus ventralis intermedius thalamotomy using the gamma knife unit was performed to make lesion in two Parkinson's disease patients. A radiation dose of 120Gy was delivered to nucleus using a single 4-mm collimator plug pattern following classic anatomical landmarks. Patients were followed for a median of 10.5 months(range 9-12 months). An independent neurological evaluation of tremor, based on the change in the United Parkinson's Disease Rating Scale tremor score(UPDRS), was correlated with a subjective evaluation. Gamma knife ventrolateral(V.O.P) thalamotomy was performed in one case of dystonia. A central dose of 150Gy was delivered and the patient was followed for 18 months. Gamma knife globus pallidus interna pallidotomy was performed in two Parkinson's disease patients. A radiation dose of 130Gy(range 120-140Gy) was delivered. Patients were followed for a median of 13 months(range 9-14 months). Result : Ventrolateral thalamotomy in dystonia produced regained left hand usage in order to be able to use the telephone. Ventralis intermedius thalamotomy produced an excellent improvement of the tremor in one case, mild improvement of the tremor in the other case of Parkinson's disease. A globus pallidus internalis(GPi) pallidotomy produced improvement of rigidity and dyskinesia : one other showed no change. There were no neurological complications. Conclusion : Gamma Knife thalamotomy considered a safe and effective technique for the treatment of tremor in Parkinson's disease. Although the results from Longer follow-up is not available yet, the short-term results seem to be encouraging.

  • PDF

Measurement of Vestibular Ocular Reflex in Normal Subjects Using Galvanic Stimulator and Videooculograph (전기자극과 VOG(Videooculograph)를 이용한 정상인의 전정 안반사 측정)

  • 김수찬;정운교;남기창;이원상;김영하;김덕원
    • Journal of Biomedical Engineering Research
    • /
    • v.22 no.6
    • /
    • pp.487-496
    • /
    • 2001
  • In this study, a galvanic stimulator providing bipolar mode controlled by a PIC(peripheral interface controller) was constructed to evaluate vestibular function The maximum load and maximum current intensity of the constant current source were 3$k\Omega$ and 5mA. respectively. and it could Produce DC, sine wavers. or Pulse waves. Eve movements of 20 normal subjects by galvanic stimulation were analyzed using a commercial videooculogragh. During stimulating with DC for 30 sec. we recorded the response of eye movement with current intensity of 0.75. 1 2, and 3 mA. Nystagmus occurred to all the subjects when the galvanic stimulus intensity was larger than 2 mA. Average SPV(slow Phase eye movement velocity) and the number of nystagmus increased from 7.1 to 4.8 deg/sec and from 17 to 48, respectively, when the stimulus current increased from 0.75 to 3 mA. All the fast eye movement of the nystagmus were the direction of the negative electrode. The asymmetry which means the difference between right- and left-eye movements decreased when the stimulus intensity increased. It is expected that this study would be useful in evaluating vestibular function and in studying basic Physiology mechanism of vestibular ocular reflex by galvanic stimulus .

  • PDF

Surface Modification of Li Metal Electrode with PDMS/GO Composite Thin Film: Controlled Growth of Li Layer and Improved Performance of Lithium Metal Battery (LMB) (PDMS/GO 복합체 박막의 리튬 금속 표면 개질: 리튬전극의 성장 제어 및 리튬금속전지(LMB) 성능 향상)

  • Lee, Sanghyun;Seok, Dohyeong;Jeong, Yohan;Sohn, Hiesang
    • Membrane Journal
    • /
    • v.30 no.1
    • /
    • pp.38-45
    • /
    • 2020
  • Although Lithium metal battery (LMB) has a very large theoretical capacity, it has a critical problem such as formation of dendrite which causes short circuit and short cycle life of the LMB. In this study, PDMS/GO composite with evenly dispersed graphene oxide (GO) nanosheets in poly (dimethylsiloxane) (PDMS) was synthesized and coated into a thin film, resulting in the effect that can physically suppress the formation of dendrite. However, PDMS has low ion conductivity, so that we attained improved ion conductivity of PDMS/GO thin film by etching technic using 5wt% hydrofluoric acid (HF), to facilitate the movement of lithium (Li) ions by forming the channel of Li ions. The morphology of the PDMS/GO thin film was observed to confirm using SEM. When the PDMS/GO thin film was utilized to lithium metal battery system, the columbic efficiency was maintained at 87.4% on average until the 100th cycles. In addition, voltage profiles indicated reduced overpotential in comparison to the electrode without thin film.

AN EXPERIMENTAL STUDY ON THE EFFECT OF THE GALVANIC CURRENT ON THE MANDIBULAR GROWTH IN RAT (Galvani전류가 백서의 하악골 성장에 미치는 영향에 관한 실험적 연구)

  • Yang, Sang-Duk;Suhr, Cheng Hoon
    • The korean journal of orthodontics
    • /
    • v.18 no.1 s.25
    • /
    • pp.189-207
    • /
    • 1988
  • In almost all biologic systems, mechanically induced electric charge separation is a fundamental phenomenon. Since the hypothesis was established that the generation of electric potentials in bone by mechanical stress including muscular force might control the activity in bone by mechanical stress including muscular force might control the activity of osseous cells and their biopolymeric byproduct, the concept of electrically mediate growth mechanism, which involves biological growth and bone remodeling by any means, in living systems has been applied clinically and experimentally to orthopedic fracture repair, the regulation of orthodontic tooth movement, epiphyseal cartilage regeneration, etc. On the other hand, recent numerous research data available show apparently that the mandibular condyle has the characteristics of growth center as well as growth site. In addition, there exists a considerable difference of opinion as to the role of external pterygoid muscle in condylar growth. In view of these evidences, this. experiment was performed to investigate the effect of the galavic current on the growth of the mandible and condyle for elucidating the nature of condylar growth. The bimetallic device was composed of silver and platinum electrode connected with resistor (3.9 Mohm), which was expected to produce galvanic current of 23.6 nA according to the galvanic principle. The 25 Sprague-Dawley rats were divided into two group, 2 week group comprising 8 animals exposed to satanic current for 2 weeks and 3 control animals not exposed for 2 weeks, 4 week group comprising 10 animals in experimental group and 4 animals in control group applied for 4 weeks respectively. The experimental rats were subjected to application of the galvanic current invasively to codylar head surface and the control groups with sham electrode. On the basis of anatomic and histologic data from the mandibular condyle of experimental and control group, the following results were obtained. 1. After 2 weeks, there was no increase of mandibular size in experimental group over that of the control group. 2. After 4 weeks, the size of the condylar head was larger in experimental group than that of the control. 3. In 2 week group, the thickness of the mitotic compartment and hypertrophic chondroblastic layer was increased in experimental group. 4. In 4 week group, the number and the size of the hypertrophic chondroblasts were increased significantly on experimental group over that of the control group. 5. The application of the satanic current caused an increase in chondrocytic hypertrophy and intercellular matrix in both groups.

  • PDF

Analysis of the Necessary Mechanical Properties of Embroiderable Conductive Yarns for Measuring Pressure and Stretch Textile Sensor Electrodes (생체 신호 측정 압력 및 인장 직물 센서 전극용 자수가 가능한 전도사의 필요 물성 분석)

  • Kim, Sang-Un;Choi, Seung-O;Kim, Joo-Yong
    • Science of Emotion and Sensibility
    • /
    • v.24 no.2
    • /
    • pp.49-56
    • /
    • 2021
  • In this study, we investigated the necessary mechanical properties of conductive multifilament yarns for fabricating the electrodes of biosignal measurement pressure and stretch textile sensors using embroidery. When electrodes and circuits for smart wearable products are produced through the embroidery process using conductive multifilament yarns, unnecessary material loss is minimized, and complex electrode shapes or circuit designs can be produced without additional processes using a computer embroidering machine. However, because ordinary missionary threads cannot overcome the stress in the embroidery process and yarn cutting occurs, herein, we analyzed the S-S curve, thickness, and twist structure, which are three types of silver-coated multifilament yarns, and measured the stress in the thread of the embroidery simultaneously. Thus, the required mechanical properties of the yarns in the embroidery process were analyzed. In the actual sample production, cutting occurred in silver-coated multifilament rather than silver-coated polyamide/polyester, which showed the lowest S-S curve. In the embroidery process, the twist was unwound through repetitive vertical movement. Further, we fabricated a piezoresistive pressure/tension sensor to measure gauge factor, which is an index for measuring biological signals. We confirmed that the sensor can be applied to the fabrication of embroidery electrodes, which is an important process in the mass production of smart wearable products.

Ionomer Binder in Catalyst Layer for Polymer Electrolyte Membrane Fuel Cell and Water Electrolysis: An Updated Review (고분자 전해질 연료전지 및 수전해용 촉매층의 이오노머 바인더)

  • Park, Jong-Hyeok;Akter, Mahamuda;Kim, Beom-Seok;Jeong, Dahye;Lee, Minyoung;Shin, Jiyun;Park, Jin-Soo
    • Journal of the Korean Electrochemical Society
    • /
    • v.25 no.4
    • /
    • pp.174-183
    • /
    • 2022
  • Polymer electrolyte fuel cells and water electrolysis are attracting attention in terms of high energy density and high purity hydrogen production. The catalyst layer for the polymer electrolyte fuel cell and water electrolysis is a porous electrode composed of a precious metal-based electrocatalyst and an ionomer binder. Among them, the ionomer binder plays an important role in the formation of a three-dimensional network for ion conduction in the catalyst layer and the formation of pores for the movement of materials required or generated for the electrode reaction. In terms of the use of commercial perfluorinated ionomers, the content of the ionomer, the physical properties of the ionomer, and the type of the dispersing solvent system greatly determine the performance and durability of the catalyst layer. Until now, many studies have been reported on the method of using an ionomer for the catalyst layer for polymer electrolyte fuel cells. This review summarizes the research results on the use of ionomer binders in the fuel cell aspect reported so far, and aims to provide useful information for the research on the ionomer binder for the catalyst layer, which is one of the key elements of polymer electrolyte water electrolysis to accelerate the hydrogen economy era.