• Title/Summary/Keyword: Electrode array

Search Result 223, Processing Time 0.024 seconds

Amperometric Electronic Tongue Based on Metal Oxide Containing Carbon Paste Electrode Array (금속 산화물을 포함한 탄소반죽 전극 어레이로 제작한 전자 혀)

  • Han Jong Ho;Kim Dong Sun;Kim Jong Sik;Yoon In Jun;Cha Geun Sig;Nam Hakhyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.4
    • /
    • pp.206-210
    • /
    • 2004
  • All array of carbon paste-based electrodes was prepared by screen printing the carbon paste modified with metal oxides $(TiO_2,\;RuO_2,\;PbO_2,\;Ni(OH)_2)$ and Prussian blue (PB). An electronic tongue system was assembled with the carbon-paste electrode array, and applied to discriminate the tastes of various commercial beverages and foods by measuring the chronoamperometric responses to the samples diluted in 0.1M carbonate buffer (pH 9.6). The results were analyzed with principal component analysis(PCA) method and plotted on two dimensional PCA coordinate; it was apparent that the amperometric electronic tongue system could discriminate the types of various foods and beverages.

Solar Energy Conversion by the Regular Array of TiO2 Nanotubes Anchored with ZnS/CdSSe/CdS Quantum Dots Formed by Sequential Ionic Bath Deposition

  • Park, Soojeong;Seo, Yeonju;Kim, Myung Soo;Lee, Seonghoon
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.3
    • /
    • pp.856-862
    • /
    • 2013
  • The photoanode electrode of $TiO_2$ nanotubes (NTs) anchored with ZnS/CdSSe/CdS quantum dots (QDs) was prepared by anodization of Ti metal and successive ionic layer adsorption and reaction (SILAR) procedure. The tuning of the band gap of CdSSe was done with controlled composition of Cd, S, or Se during the SILAR. A ladder-like energy structure suitable for carrier transfer was attained with the photoanode electrode. The power conversion efficiency (PCE) of our solar cell fabricated with the regular array of $TiO_2$ NTs anchored with CdSSe/CdS or CdSe/CdS QDs [i.e., (CdSSe/CdS/$TiO_2NTs$) or (CdSe/CdS/$TiO_2NTs$)] was PCE = 3.49% and 2.81% under the illumination at 100 mW/$cm^2$, respectively. To protect the photocorrosion of our solar cell from the electrolyte and to suppress carrier recombination, ZnS was introduced onto CdSSe/CdS. The PCE of our solar cell with the structure of a photoanode electrode, (ZnS/CdSSe/CdS/$TiO_2$ NTs/Ti) was 4.67% under illumination at 100 mW/$cm^2$.

Electronic Tongue Composed of Mini-Electrode Array in Flow Cell (소형전극 어레이로 구성한 흐름계형 전자혀)

  • Shim, Jun Ho;Shim, Jae Hoon;Seo, Sung Seok;Oh, Hyun Joon;Han, Jong Ho;Nam, Hakhyun;Cha, Geun Sig
    • Analytical Science and Technology
    • /
    • v.17 no.3
    • /
    • pp.217-224
    • /
    • 2004
  • A taste sensor system composed of mini electrode array was built in a flow cell. Potentiometric signals from 9 electrodes were collected for drinking waters and alcoholic beverages which were diluted in a low concentration buffer solution (0.005 M Tris-$H_2SO_4$ pH 7.2) for the measurement. The measured results were treated with the principal component analysis (PCA), and grouped on a two or three dimensional PCA coordinate to discriminate the tastes of each beverage. It is demonstrated that the taste sensor system of this work may be used for the quality control of beverages in production or the examination of their taste variation in the market.

Development and Verification of 4-Electrode Resistivity Probe (4전극 전기비저항 탐사장비의 개발 및 검증)

  • Kim, Joon-Han;Yoon, Hyung-Koo;Jung, Soon-Hyuck;Lee, Jong-Sub
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.29 no.3C
    • /
    • pp.127-136
    • /
    • 2009
  • The objective of this study is the development and verification of the 4-electrode resistivity probe (4ERP) for the estimation of electrical properties of the saturated soils. The 4ERPs with wedge and plane types are manufactured to obtain the electrical resistivity without polarization at the electrodes by using Wenner array. The wedge type is for the penetration into the soil samples and the plane type is for the installation into the cells used for the laboratory tests. The consolidation tests are carried out by using 6 types of glass beads and 3 types of sands in size. The test results show that the electrical resistivity increases with a decrease in the porosity, and the constant m used in Archie's law is dependent on the particle shape rather particle size. The one dimensional liquefaction tests show that the porosity obtained by the 4ERP is similar to that determined by the volume fraction. The penetration of the 4ERP into the large scale calibration chamber produces the resistivity profiles. This study demonstrates that the 4ERP may effectively estimate the porosity of the saturated soils.

Interstitial Hyperthermia by Radiofrequency Needle Electrode System : Phantom and Canine Brain Studies (8 MHz 라디오파를 이용한 자입식 온열치료 -조직등가물질을 통한 온도분포 및 개 뇌실질의 조직병리 변화에 관한 연구-)

  • Lee, Hyung-Sik;Chu, Sung-Sil;Sung, Jin-Sil;Suh, Chang-Ok;Kim, Gwi-Eon;Loh-John-Juhn-Kyu;Kim, Young-Soo;Kim, Sun-Ho;Chung, Song-Sup;Han, Eun-Kyung;Kim, Tae-Seung
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.27-35
    • /
    • 1991
  • An interstitial radiofrequency needle electrode system was constructed for interstitial heating of brain tissue. Radiofrequency electrodes with Thermotron RF 8 were tested in an agar phantom and in a normal canine brain to determine how variations in physical factors affected temperature distributions. Temperature distributions were checked after heating with 1 mm diameter needle electrode implants on the corners of 1 and 2 cm squares in a phantom and plot isotherms for various electrodes arrangement. We observed that the 1 cm square array would heat a volume with a 1.25 cm radius circular field cross section to therapeutic temperatures ($90\%$ relative SAR using Tm) and the 2 cm square array with a 1.75 cm radius rectangular field with central inhomogeneity. With 2 cm long electrode implants, we observed that the 1 cm square array would heat a 3 cm long sagittal section to therapeutic temperature ($90\%$ relative SAR using Tm). We found that radiofrequency electrodes could be selected to match the length of the heating area without affecting its performance. The histopathological changes associated with RF heating of normal canine brains have been correlated with thermal distributions. RF needle electrode heating was applied for 50min to generate tissue temperatures of $43^{\circ}C$. We obtained a quarter of the heated tissue material immediately after heating and sacrificed at intervals from $7\sim30$days. The acute stage (immediately after heating) was demonstrated by liquefactive necrosis, pyknosis of neuronal element in the gray matter and by some polymer-phonuclear leukocytes infiltration. The appearance of lipid-laden macrophages surrounding the area of liquefaction necrosis was demonstrated in all three sacrificed dogs. Mild gliosis occurring around the necrosis was demonstrated in the last sacrificed (Days 30) canine brain.

  • PDF

Electrochemical Gene Detection Using Microelectrode Array on a DNA Chip

  • Park, Yong-Sung;Kwon, Young-Soo;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.4C no.4
    • /
    • pp.145-148
    • /
    • 2004
  • In this study, a DNA chip with a microelectrode array was fabricated using microfabrication technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5' end were immobilized on the gold electrodes by a DNA arrayer. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 and concentrated at the electrode surface through association with the formed hybrid. This suggested that this DNA chip could recognize the sequence specific genes.

Electrochemical Detection of Genes Using Microeledtrode Array DNA Chip (미소전극어에이형 DNA칩을 이용한 유전자의 전기화학적 검출)

  • Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2125-2127
    • /
    • 2004
  • In this paper, a DNA chip with a microelectrode array was fabricated using microfabrication technology. Several probe DNAs consisting of mercaptohexyl moiety at their 5 end were immobilized on the gold electrodes by DNA arrayer. Then target DNAs were hybridized and reacted with Hoechst 33258, which is a DNA minor groove binder and electrochemically active dye. Linear sweep voltammetry or cyclic voltammetry showed a difference between target DNA and control DNA in the anodic peak current values. It was derived from Hoechst 33258 concentrated at the electrode surface through association with formed hybrid. It suggested that this DNA chip could recognize the sequence specific genes.

  • PDF

Novel Structure of 21.6 inch a-Si:H TFT Array for the Direct X-ray Detector

  • Kim, Jong-Sung;Choo, Kyo-Seop;Park, June-Ho;Chung, In-Jae;Joo, In-Su
    • Journal of Information Display
    • /
    • v.1 no.1
    • /
    • pp.29-31
    • /
    • 2000
  • A 21.6" a-Si:H TFT array for direct conversion X-ray detector with 2480 by 3072 pixels is successfully developed. To obtain X-ray image of satisfactory quality, a novel structure with a storage electrode on BCB is proposed. The structure reduces the parasitic capacitance of data line, which is one of the main sources of signal noise. Also, the structure shows greater resistance to failure than that of the conventional design.

  • PDF

Flexible Modules Using MEMS Technology (MEMS 기술을 이용한 Flexible Module)

  • 김용준;황은수;김용호;이태희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.223-227
    • /
    • 2003
  • A new flexible electronic packaging technology and its medical applications are presented. Conventional silicon chips and electronic modules can be considered as "mechanically rigid box." which does not bend due to external forces. This mechanically rigid characteristic prohibits its applications to wearable systems or bio-implantable devices. Using current MEMS (Microelectromechanical Systems) technology. a surface micromachined flexible polysilicon sensor array and flexible electrode array fer neural interface were fabricated. A chemical thinning technique has been developed to realize flexible silicon chip. To combine these techniques will result in a realization of truly flexible sensing modules. which are suitable for many medical applications.

  • PDF

Fabrication of Planar-type Semiconductor Microelectrode Array and Its Application to Peripheral Nerve of Invertebrates (평판형 반도체 미세전극 어레이 제작 및 이를 이용한 무척추 동물의 말초신경다발 신호기록)

  • Hwang, E.J.;Yoon, T.H.;Kim, S.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.145-146
    • /
    • 1998
  • A planar-type silicon microelectrode array has been fabricated and used successfully in obtaining simultaneous multichannel recordings from peripheral nerve of invertebrates. This paper demonstrates that planar-type semiconductor electrode arrays are useful for studying traveling wave properties of action potential.

  • PDF