• 제목/요약/키워드: Electrode array

검색결과 223건 처리시간 0.025초

STS316L 강관의 수평자세 용접을 위한 GTAW 용접조건의 최적화 (Optimization of GTAW Parameters for Horizontal Welding of a STS316L Pipe)

  • 이형근;방경식
    • Journal of Welding and Joining
    • /
    • 제33권5호
    • /
    • pp.47-52
    • /
    • 2015
  • In this study, it was tried to analyze the effects of welding parameters on the weld penetration and aspect ratio when a STS316L pipe was welded in a horizontal position by GTAW. Experiments were systematically designed using a L18 orthogonal array, and the effects of welding parameters were statistically analyzed by ANOVA(Analysis of Variance). The shielding gas type has the largest effect on both the penetration and aspect ratio. The welding current type and shielding gas flow rate have a little effect on the penetration, whereas the electrode tip angle has a little effect on the aspect ratio. When welded at a selected welding condition, which is composed of He shielding gas, pulse current of 300/45 A, electrode tip angle of 90o, and shielding gas flow rate of 30 l/min, the estimated interval at least 95 % confidence was $1.99{\pm}0.18mm$ for the penetration and $0.31{\pm}0.04$ for the aspect ratio. From the confirmation experiments, the average penetration and aspect ratio were well agreed with the estimation as 1.96 mm and 0.30, respectively. Additionally, the effects of the welding speed and welding current on the penetration and aspect ratio were experimented and analyzed by linear regression. The penetration was linearly increased with the decrease of the welding speed and with the increase of the welding current, but the aspect ratio showed a tendency to a little decrease with the increase of both the welding speed and current.

고전압 대전류용, Seal-off TVS(Triggered Vacuum Switch) 연구 (Study of Seal-off Triggered Vacuum Switch(TVS) for High Voltage and High Current)

  • 박성수;한영진;김상희;권영건;김승환;박용정;홍만수;남상훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1823-1826
    • /
    • 2002
  • The purpose of this experiment was to develope Triggered Vacuum Switch (TVS) for the high voltage and high current. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. It consists of electrode, ceramic chamber, getter and trigger. Currently, triggered vacuum switch (TVS) with seal-off has been designed and fabricated at PAL. An experimentation and trigger devices for TVS were designed for testing characteristics of electricity. For making the prototype of TVS, it is developed of fabrication process and fined of electrode material. The fabrication of the TVS is a lot of process which have manufacturing of part, chemical clean, ceramic brazing and metal welding. The fabricated TVS is tested of leak for vacuum, hold-off voltage and conditioning of trigger system. The TVS has pinch-off after it is removed of gas in the TVS and activated of getter in degassing furnace. The prototype TVS tested about 20 kV, 75 kA, 83 ${\mu}s$ with 100 kJ capacitor bank and inductance 5 ${\mu}H$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

인도네시아 중부 칼리만탄 타란지역에서의 물리탐사 (Geophysical Survey in the Taran Area on the Central Kalimantan, Indonesia)

  • 조진동;김인준;박인화
    • 자원환경지질
    • /
    • 제35권2호
    • /
    • pp.155-162
    • /
    • 2002
  • 천열수 광상 함금석영맥이 도처에 발달하고 있는 인도네시아 중부 칼리만탄 타란 지역에서 천부 지질정보 획득(지질구조 및 광상분포 확인)을 목적으로 1999년 9월30일부터 10월27일 가지 28일간의 일정으로 자연전위탐사, In-suite 대자율 측정 및 전기 비저항 탐사법를 수행하였다. 자연전위탐사/in-suite 대자율 측정은 10m$\times$250m 간격으로 5개 측선에서, 쌍극자 탐사는 전극간격 ${\alpha}$=30 m, 전극배열 n=7으로 1개 측선에서 행하였다. 탐사결과. 한금 석영맥의 분포지역은 유화광물을 많이 포함하는(은, 아연 및 연의 광화작용)형태, 유화광물을 적게 포함하는(금 광화작용)형태 지역으로 분리 할 수 있다. 측선5에서 낮은 비저항값을 보여주는 구간은 파쇄대, 유화광물을 많이 포함하고 있는 구간을 의미한다.

2차원 지하구조 규명을 위한 전극배열의 효율성 (Effectiveness of the Electrode Arrays for Delineating 2-D Subsurface Structure)

  • 윤종렬;이기화
    • 자원환경지질
    • /
    • 제29권3호
    • /
    • pp.345-355
    • /
    • 1996
  • 2차원 지하구조를 해석함에 있어 1차원 역산에 근거한 수직탐사자료 해석의 타당성과 수평탐사에 있어 여러가지 전극배열법의 효율성이 연구되었다. 수직암맥, 판상기둥, 매몰수직단층, 램프 (ramp), 복합구조와 같은 2차원 모델로부터 유한차분법을 이용하여 3 포인트, 쌍극자, 베너 (Wenner), 슐럼버저 (Schlumberger) 수평탐사의 겉보기비저항 곡선을 구하고 이를 비교 분석하였다. 수직탐사의 경우에는 슐럼버저와 베너 배열법에 대하여 1차원 역산자료를 내심하여 얻은 자료로부터 2차원 단면도를 구하여 비교하였다. 이러한 2차원 단면도는 각 모델에 대하여 비저항의 수칙, 수평적인 경계면을 잘 보여주고 있다. 또한 슐럼버저 수평탐사의 겉보기 비저항 곡선은 수직적인 비저항의 경계면을 잘 보여주고 있다. 전반적으로 수직, 수평 전기탐사의 경우에 있어 슐럼버저 배열법이 다른 전극배열법보다 우수한 결과를 보여주고 있다. 본 연구로부터, 1차원 역산에 근거한 2차원 지하구조의 해석이 가능함을 알 수 있다.

  • PDF

수처리용 다중 유전체 방벽 방전 플라즈마 반응기 개발 (Development of Multi Dielectric Barrier Discharge Plasma Reactor for Water Treatment)

  • 김동석;박영식
    • 한국환경과학회지
    • /
    • 제22권7호
    • /
    • pp.863-871
    • /
    • 2013
  • Dielectric discharges are an emerging technique in environmental pollutant degradation, which that are characterized by the production of hydroxyl radicals as the primary degradation species. For practical application of the plasma reactor, reactor that can handle large amounts of water are needed. Plasma research to date has focused on small-scale water treatment. This study was carried out basic study for scale-up of a single DBD (dielectric barrier discharge) plasma reactor. The degradation of N, N-Dimethyl-4-nitrosoaniline (RNO, indicator of the generation of OH radical) was used as a performance indicator of multi-plasma reactor. The experiments is divided into two parts: design parameters [effect of distance of single plasma module (1~14 cm), arrangement of ground electrode (single and multi), rector number (1~5) and power number (1~5)]; operation parameter [effect of applied voltage (60~220 V), air flow rate (1~5 L/min), electric conductivity of solution ($1.4{\mu}S/cm$, deionized water)~18.8 mS/cm (addition of NaCl 10 g/L) and pH (5~9)]. Considering the electric stability of the plasma reactor, optimum spacing between the single plasma module was 2 cm. Multi discharge electrodes - single ground electrode array was selected. Combination of power 3-plasma module 5 was the optimal combination for maximum RNO degradation. The optimum 1st voltage and air flow rate for RNO degradation were 180 V and 4 L/min, respectively. The pH and conductivity of the solution was not influencing the RNO degradation.

Polystyrene 입자 정렬을 이용한 성게 구조 ZnO 나노막대 가스 센서의 특성 (Properties of Urchin-Structured Zinc Oxide Nanorods Gas Sensor by Using Polystyrene Sphere Array)

  • 김종우;김도훈;기태훈;박정혁;명재민
    • 한국재료학회지
    • /
    • 제27권12호
    • /
    • pp.658-663
    • /
    • 2017
  • Urchin-structured zinc oxide(ZnO) nanorod(NR) gas sensors were successfully demonstrated on a polyimide(PI) substrate, using single wall carbon nanotubes(SWCNTs) as the electrode. The ZnO NRs were grown with ZnO shells arranged at regular intervals to form a network structure with maximized surface area. The high surface area and numerous junctions of the NR network structure was the key to excellent gas sensing performance. Moreover, the SWCNTs formed a junction barrier with the ZnO which further improved sensor characteristics. The fabricated urchin-structured ZnO NR gas sensors exhibited superior performance upon $NO_2$ exposure with a stable response of 110, fast rise and decay times of 38 and 24 sec, respectively. Comparative analyses revealed that the high performance of the sensors was due to a combination of high surface area, numerous active junction points, and the use of the SWCNTs electrode. Furthermore, the urchin-structured ZnO NR gas sensors showed sustainable mechanical stability. Although degradation of the devices progressed during repeated flexibility tests, the sensors were still operational even after 10000 cycles of a bending test with a radius of curvature of 5 mm.

취약대가 존재하는 제방의 누수 탐지를 위한 전기비저항 탐사의 적용성 연구 (A Study on Application of Electrical Resistivity Survey to Detect the Leakage of Embankment with Weak Zone)

  • 박삼규;김재홍
    • 한국지반환경공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.5-13
    • /
    • 2013
  • 댐 및 저수지 제방의 누수현상은 통관 주변에서 주로 일어나며 평상 시에는 제방에 큰 영향을 미치지 않지만, 호우나 장마철과 같이 저수지 수위가 상승하면 제방의 붕괴 위험을 가져온다. 따라서 이러한 수맥과 경로를 조사하는 것은 재해 예방과 제방 관리의 측면에서 매우 중요하다. 본 연구에서는 수치적인 방법과 실험적인 방법을 사용하여 통관이 취약대로 작용하는 댐 및 제방에서의 누수현상을 분석하였다. 누수탐지에는 전기비저항 탐사를 사용하여 그 유용성을 검토하였다. 수치해석의 결과에서는 취약대의 크기와 위치에 따라 전극 간격의 설정이 중요함을 보여주었고, 모형제방의 누수실험에서는 전극간격을 0.3m로 쌍극자 배열을 사용하는 것이 가장 좋은 결과를 얻을 수 있을 것으로 판단되었다. 누수현상의 분석을 통하여 댐 및 제방시설물의 누수탐지에 전기 비저항 탐사가 유용함을 확인하였다.

수리지질학 연구에 이용되는 대규모 끄는 방식 전기비저항 배열 자료의 1 차원 강력한 역산 (Robust 1D inversion of large towed geo-electric array datasets used for hydrogeological studies)

  • Allen, David;Merrick, Noel
    • 지구물리와물리탐사
    • /
    • 제10권1호
    • /
    • pp.50-59
    • /
    • 2007
  • 물위나 육지에서 끄는 방식의 전기비저항 배열법의 등장은 그 자료량의 규모를 항공전자탐사의 규모에 가깝게 만들었으며, 이렇게 얻어진 자료들의 대부분은 해석을 위한 1 차원 역산이 시도되었다. 이 자료들의 믿을만한 해석과 자료처리를 실행 가능화시키기 위해서는 강력하고 완벽한 자동화 공정은 필수 불가결한 요소이다. 하상이나 염수 대수층의 상부와 같은 뾰족한 경계를 찾아내야 하므로 평활화제한법의 이용은 최소화 시켜야 한다. 적절한 역산 방식이라면 신호를 감쇠시키는 전도성 기반암의 경우에는 해석의 오류를 피하기 위해 낮은 신호대 잡음비를 현명하게 다룰 수 있어야 한다. 이를 위해 각각의 전극 배열법에 대해 하나의 탄력적 두께를 갖는 층을 운용하는 잡음 인지 역산 방법이 코딩되었다. 잡음 인지 역산법은 만약 전도성 기반암이 선호를 감쇠시켜 잡음 수준보다 작게 만들면 이를 감지하여 적당한 위치에 전도성 기반암을 갖는 모형을 구성해 준다. 초기모형의 층들은 4 극으로 구성된 각 전기 배열법의 유효깊이가 미치는 범위 내에서 제 위치를 찾아가게 된다. 이 알고리듬은 4 극의 유효깊이가 대략 지수함수적인 배열을 이루어 자료가 얻어졌을 때 가장 최상의 결과를 나타낸다. 접지저항을 줄이기 위한 선전극이나 용량선 안테나(capacitive-antenna)에 의한 자료의 역산도 가능하다. 이 논문은 이론자료와 오스트레일리아의 Murray 강의 염분차단 계획의 예를 들어 개발된 알고리듬의 유용성을 보여주었다.

FET 센서 어레이를 이용한 이온 측정 시스템의 신뢰도 개선 (Reliability improvement of an ion-measuring system using FET sensor array)

  • 최정태;이승협;김영진;이영철;조병욱;손병기
    • 센서학회지
    • /
    • 제8권4호
    • /
    • pp.341-346
    • /
    • 1999
  • 일반적으로 FET형 전해질 이온 센서는 유리전극에 비하여 여러 가지 장점을 가지고 있으나 드리프트 및 기억효과가 있고 재현성이 부족한 단점을 가지고있어 이온 측정 시스템에 적용한 경우 전체적인 시스템의 신뢰성 저하를 가져온다. 이러한 점을 개선하기 위하여 본 논문에서는 8개의 동종 FET형 전해질 이온 센서 어레이를 사용하여 높은 신뢰성을 가지며 4종류의 이온($H^+$, $Na^+$, $K^+$, $Ca^{2+}$) 농도 측정이 가능한 시스템을 개발하였다. 개발된 측정 시스템은 전자식 스위치를 사용하여 단일의 신호 검출회로로 8개의 센서 신호를 검출하는 방법을 채택하였다. 또한 8개의 센서 신호를 삽입 정렬을 하여 신뢰성이 낮은 센서를 제외시키는 신호 처리 알고리즘을 개발하여 신뢰성을 향상시켰다. 제작된 시스템으로 3종류의 이온($H^+$, $Na^+$, $K^+$) 농도를 측정한 결과 개발된 신호처리 알고리즘은 여러 개의 센서 신호를 단순히 산술 평균을 취하는 방식에 비하여 오차의 범위를 더욱 줄일 수 있는 것으로 나타났으며, 기존의 단채널 방식의 전해질 이온 측정 시스템과 비교해볼 때 우수한 신뢰성을 가짐을 알 수 있었다.

  • PDF

On-site Water Nitrate Monitoring System based on Automatic Sampling and Direct Measurement with Ion-Selective Electrodes

  • Kim, Dong-Wook;Jung, Dae-Hyun;Cho, Woo-Jae;Sim, Kwang-Cheol;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • 제42권4호
    • /
    • pp.350-357
    • /
    • 2017
  • Purpose: In-situ monitoring of water quality is fundamental to most environmental applications. The high cost and long delays of conventional laboratory methods used to determine water quality, including on-site sampling and chemical analysis, have limited their use in efficiently managing water sources while preventing environmental pollution. The objective of this study was to develop an on-site water monitoring system consisting mainly of an Arduino board and a sensor array of multiple ion selective electrodes (ISEs) to measure the concentration of $NO_3$ ions. Methods: The developed system includes a combination of three ISEs, double-junction reference electrode, solution container, sampling system consisting of three pumps and solenoid valves, signal processing circuit, and an Arduino board for data acquisition and system control. Prior to each sample measurement, a two-point normalization method was applied for a sensitivity adjustment followed by an offset adjustment to minimize the potential drift that could occur during continuous measurement and standardize the response of multiple electrodes. To investigate its utility in on-site nitrate monitoring, the prototype was tested in a facility where drinking water was collected from a water supply source. Results: Differences in the electric potentials of the $NO_3$ ISEs between 10 and $100mg{\cdot}L^{-1}$ $NO_3$ concentration levels were nearly constant with negative sensitivities of 58 to 62 mV during the period of sample measurement, which is representative of a stable electrode response. The $NO_3$ concentrations determined by the ISEs were almost comparable to those obtained with standard instruments within 15% relative errors. Conclusions: The use of the developed on-site nitrate monitoring system based on automatic sampling and two-point normalization was feasible for detecting abrupt changes in nitrate concentration at various water supply sites, showing a maximum difference of $4.2mg{\cdot}L^{-1}$ from an actual concentration of $14mg{\cdot}L^{-1}$.