• Title/Summary/Keyword: Electrode Spacing

Search Result 100, Processing Time 0.026 seconds

Discharge Characteristics of SF6 Mixture Gases due to Processing Status of needle electrode under Non-Uniform Fields (불평등 전계 하에서의 침전극 가공상태에 따른 SF6혼합가스의 방전특성)

  • Go, Y.S.;Seo, H.J.;Rhie, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.198-199
    • /
    • 2006
  • AC spark discharge voltage of SF6/C02and SF6/N2 containing various mixed rate in volume percent (1, 5 and 10%) of SF6 in non-uniform fields are investigated. The needle to plane electrode gap spacing was 5 and 10 mm, and the gas pressure was varied within the range of 0.1${\sim}$0.7 MPa. We have observed a N-characteristic typical for the electronegative gases even in gas mixtures of 1% SF6 with CO2 and N2 as buffer gases. Especially, the materials of the needle electrode affect the insulation properties of the gas mixtures drastically. On the contrary to the case of needle electrodes made by mild steel or high carbon steel, the N-characteristics are hardly perceived in the case of stainless steel needle in this experiment.

  • PDF

FE model of electrical resistivity survey for mixed ground prediction ahead of a TBM tunnel face

  • Kang, Minkyu;Kim, Soojin;Lee, JunHo;Choi, Hangseok
    • Geomechanics and Engineering
    • /
    • v.29 no.3
    • /
    • pp.301-310
    • /
    • 2022
  • Accurate prediction of mixed ground conditions ahead of a tunnel face is of vital importance for safe excavation using tunnel boring machines (TBMs). Previous studies have primarily focused on electrical resistivity surveys from the ground surface for geotechnical investigation. In this study, an FE (finite element) numerical model was developed to simulate electrical resistivity surveys for the prediction of risky mixed ground conditions in front of a tunnel face. The proposed FE model is validated by comparing with the apparent electrical resistivity values obtained from the analytical solution corresponding to a vertical fault on the ground surface (i.e., a simplified model). A series of parametric studies was performed with the FE model to analyze the effect of geological and sensor geometric conditions on the electrical resistivity survey. The parametric study revealed that the interface slope between two different ground formations affects the electrical resistivity measurements during TBM excavation. In addition, a large difference in electrical resistivity between two different ground formations represented the dramatic effect of the mixed ground conditions on the electrical resistivity values. The parametric studies of the electrode array showed that the proper selection of the electrode spacing and the location of the electrode array on the tunnel face of TBM is very important. Thus, it is concluded that the developed FE numerical model can successfully predict the presence of a mixed ground zone, which enables optimal management of potential risks.

A Study on Application of Electrical Resistivity Survey to Detect the Leakage of Embankment with Weak Zone (취약대가 존재하는 제방의 누수 탐지를 위한 전기비저항 탐사의 적용성 연구)

  • Park, Samgyu;Kim, Jaehong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.5-13
    • /
    • 2013
  • The water leakage of reservoir embankment usually occurs around channelling pipes, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain and the rainy season in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disaster prevention and embankment maintenance. The water leakage in dams and levees where the channelling pipes are working as weak zone was analyzed by using both numerical simulation and experimental method in this study. To detect the water leakage, an electrical resistivity survey was used and investigated for its' usability. The numerical results show the size and location of weak zone increases the importance of selection of electrode spacing. The leakage experiments of model embankment present the best result is obtained under the conditions of electrode spacing of 0.3m and dipole-dipole array. By studying the water leakage in dams and levees, the electrical resistivity survey is observed it is a very useful method to predict the leakage.

Fundamental Study on the Strength and Heat Transferring Charcteristic of Cement Composite with Waste CNT (폐CNT를 혼입한 시멘트 복합체의 강도 및 열전달 특성에 대한 기초적 연구)

  • Koo, Hounchul;Kim, Woon-Hak;Oh, Hongseob
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.66-73
    • /
    • 2022
  • The purpose of this study was to develop self-heating concrete by utilizing the conduction resistance of concrete in order to reduce the risk of occurrence of black ice in the concrete pavement in winter and to prevent damage caused by freez-thawing effect. For this purpose, it was attempted to evaluate the strength and temperature exothermic characteristics using powder and liquid waste CNTs and a waste cathode agent as a conduction promotion. It was analyzed that liquid waste CNT had an effective dispersion degree in the mortar and a small decrease in strength occurred. In addition, DC 24 V was supplied by applying steel mesh, copper foil and copper wire to the mortar as electrodes, and the temperature change characteristics according to the mixing ratio of spent CNTs, anodes and carbon fibers were evaluated. In addition, by evaluating the temperature characteristics according to the electrode spacing from the selected optimal mixture, it was confirmed that it had sufficient heating characteristics up to an electrode spacing of 100 mm up to AC 50 V.

The Characteristics of the Ionic Wind Generation with Corona Electrodes Installed in Form of the Ring (환형 배치된 코로나 전극에 의한 이온풍 발생 특성)

  • Kim, Jin-Gyu;Jung, Jae-Seung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.54-59
    • /
    • 2014
  • The electric power can be converted into the mechanical power by a corona discharge system. This way has not stronger force than a electric motor. But it has been applied in various industrial fields because of many advantages, no moving parts, smaller noise, simpler structure, minimizing et al. In this paper, corona discharge system with multiple corona electrode installed in form of the ring, has been studied by focusing on the electrical and mechanical characteristics. Intensity of the corona discharge depends on applied electric field, and electric field is related to the applied voltage, discharge gap spacing(s), distance between each corona electrodes(d). As a result, in the case d/s=0.9, most intensive discharge occurred in this experiments. In the region of d/s<0.9, ionic wind velocity has saturation value in spite of decreasing corona current, because each ion velocities increase by the increasing electric field.

SAW Filter Fabrication and its Power Durability (SAW Filter 제작과 전력 내구성 검토)

  • 김동수;강성건;김흥락;김광일;남효덕;이만형
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.109-112
    • /
    • 1998
  • SAW filters of transversal type were fabricated on some piezoelectric substrate of the LN 128 $^{\circ}$ Y-X waters through the simulation in which the number of IDT and window function were changed for the required frequency, and the mask making. Their IDT spacing and width were 1.63$\mu\textrm{m}$, 1.239$\mu\textrm{m}$, respectively. Titanium thin films having different thicknesses were introduced between the Al electrode and the substrate for improving the power resistance strength due to its high temperature durability and good adhesion characteristics. All of specimens showed similar insertion loss results, which means the possibility of introducing the Ti layer though it is known to have a higher resistivity leading to a worse insertion loss result. Ti inserted specimens had a better power durability than that of pure Al electrode though their thickness had no effect on the performance.

  • PDF

A Study on the Characteristics of Discharge and Ozone Generation for Ozonizer of Neon Discharge Tube Type (네온방전관형 오존발생기의 방전특성 및 오존생성특성에 관한 연구)

  • Song, H.J.;Woo, S.H.;Kim, S.G.;Kim, K.C.;Lee, K.S.;Lee, D.I.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1857-1860
    • /
    • 1996
  • In this paper, ozonizer of neon discharge tube type( Neolamp ) by using silent discharge has been designed and manufactured. The discharge and ozone generation characteristics of Neolamp have been studied with variation of turn-on number( N ) of Neolamp, quality( Q ) and shape of external electrode. The discharge voltage is proportional to gap spacing of spiral external electrode( G ) for constant applied volatge. The discharge current is inversely proportional to G for constant applied volatge. The ozone concentration is inversely proportional to Q and G. Also, ozone concentration and generation are proportional to N. The sterilization characteristics of Escherichia coil have been obtained more than 97[%] at $1.30[mg/{\ell}]$ of liquid ozone concentration.

  • PDF

Reduction of Height of Taylor Cone Caused by Water Surface Discharge and Its Ozone Generation Characteristics (수표면방전의 방전 수돌기의 높이제한과 오존발생특성)

  • Park, Seung-Lok;Kim, Jin-Gyu;Kim, Ju-Yong;Lee, Dae-Hee;Moon, Jae-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.7
    • /
    • pp.334-339
    • /
    • 2001
  • A silent type ozone generator using water surface has been studied and improved its ozone generation characteristics by the controlling the height of Taylor cone by installing a mesh electrode, a dielectric bed of glass beads in the just under th surface of the water. The current-voltage characteristics and characteristics of ozone generation quantity of the test system were investigated and discharge current oscillograms of the each cases of the mesh electrode and the beds were observed and compared each other to analyze the discharge conditions. The Taylor cone height could be the cause of the discharge bridge to decrease the ozone generation on the discharge spacing. In this study, the hight of Taylor cone could be reduced greatly by installing the mesh and the glass beads bed just under the water surface. Therefore a higher ozone generation also could be obtained.

  • PDF

Synthesis of Multiwall Carbon Nanotube/Graphene Composite by Aerosol Process and Its Characterization for Supercapacitors (에어로졸 공정에 의한 Multiwall carbon nanotube/Graphene 복합체 제조 및 슈퍼커패시터 특성평가)

  • Jo, Eun Hee;Kim, Sun Kyung;Chang, Hankwon;Lee, Chong Min;Park, Su-Ryeon;Choi, Ji-hyuk;Jang, Hee Dong
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.127-134
    • /
    • 2016
  • A multiwall carbon nanotube (MWCNT)/graphene (GR) composite was synthesized for an enhanced supercapacitor. Aerosol spray pyrolysis (ASP) was employed to synthesize the MWCNT/GR composites using a colloidal mixture of MWCNT and graphene oxide (GO). The effect of the weight ratio of the MWCNT/GO on the particle properties including the morphology and layered structure were investigated. The morphology of MWCNT/GR composites was generally the shape of a crumpled paper ball, and the average composite size was about $5{\mu}m$. MWCNT were uniformly dispersed in GR sheets and the MWCNT not only increase the basal spacing but also bridge the defects for electron transfer between GR sheets. Thus, it was increasing electrolyte/electrode contact area and facilitating transportation of electrolyte ion and electron in the electrode. Electrochemical data demonstrate that the MWCNT/GR (weight ratio=0.1) composite possesses a specific capacitance of 192 F/g at 0.1 A/g and good rate capability (88% capacity retention at 4 A/g) using two-electrode testing system.

Influence of intermixed gas on stable townsend discharge (안정 Townsend 방전에 대한 혼입가스의 영향)

  • 하성철
    • 전기의세계
    • /
    • v.30 no.5
    • /
    • pp.306-312
    • /
    • 1981
  • The Townsend discharge domain is generally observed with stable positive characteristics in N$_{2}$ gas discharge at low pressures differently in the others, which transfer immediately to glow dischage after self-sustaining discharge starts. In this paper, the presence of the stable Townsend discharge, applied voltage-discharge current characteristics and the effect of disgased electrode surface on stable townsend discharge are studied experimentaly in N$_{2}$ gas mixed with 0.05% of No in volume. As the result of this experiment, the stable Townssend discharge is observed only in pure nitrogen with the valve of pd.geq.8[torr.cm] (p=gas pressure, d=gap spacing), but not in gas mixtures. This is considered that No gas in gas mixtures disexcites effectively the metestble state of nitrogen.

  • PDF