• Title/Summary/Keyword: Electrode Body

Search Result 169, Processing Time 0.026 seconds

Reduction of short channel Effects in Ground Plane SOI MOSFET′s (Growld Plane SOI MOSFET의 단채널 현상 개선)

  • ;;;;Jean-Pierre Colinge
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.4
    • /
    • pp.9-14
    • /
    • 2004
  • This paper reports the measurement and analysis of the short channel effects and the punchthrough voltage of SOI-MOSFET with a self-aligned ground plane electrode in the silicon mechanical substrate underneath the buried oxide. When the channel length is reduced below 0.2${\mu}{\textrm}{m}$ it is observed that the threshold voltage roll-off and the subthreshold swing with channel length are reduced and DIBL is improved more significantly in GP-SOI devices than FD-SOI devices. It is also observed from the dependence of threshold voltage with substrate biases that the body factor is a higher in GP-SOI devices than FD-SOI devices. From the measurement results of punchthrough voltage, GP-SOI devices show the higher punchthrough voltages than FD-SOI devices

AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS (수종 임플랜트 금속의 내식성에 관한 전기화학적 연구)

  • Jeon Jin-Young;Kim Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.3
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Ultrastructural Changes in the Neuropil of the Anterior Thalamic Nucleus following the Lesion in the Mamillary Body (유두체 손상이 시상전핵 조직상의 미세구조에 미치는 영향)

  • Lee, Byoung-Ho;Ko, Jeong-Sik;Ahn, E-Tay;Yang, Nam-Gil
    • Applied Microscopy
    • /
    • v.18 no.2
    • /
    • pp.177-186
    • /
    • 1988
  • Degeneration of the axon terminals of mamillo-thalamic tract following the electrical coagulation of mamillary body is well known. In this study, the author investigated the ultrastructural alterations of neuropil components, initiated by terminal degenerations. Rats weighing approximately 250 gm were fixed on the stereotaxic instrument(David Kopf Inc., Heavy duty model), and NE 300 active electrode(Rhodes Med. Instr. Inc.) was introduced to the mamillary position of anterior 3.8 mm, lateral 0.5 mm, height 3.8 mm and lateral angle of $23^{\circ}$ according to De Groot's Atlas. Electric current of 20 mA was applied during 1 minute between active and inactive electrodes with Radio Frequency Lesion Generator(RFG 4, Radionics Inc.). Two hours, 2 days, 1 week and 2 weeks following the electrical coagulation of mamillary body, ipsilateral anterior thalamic nucleus was fixed in 1% glutaraldehyde-l% paraformaldehyde and 2% osmium tetroxide, embedded in Araldite mixture, cutted with LKB ultra tome V, stained with uranyl acetate-lead citrate and observed with JEOL 100 CX electron microscope. Observed results were as follows; 1. Degenerated mamillo-thalamic synapses were observed to form asymmetric axospinous or axo-dendritic types. 2. Terminal degeneration was not easily discernible at 2 hours interval after mamillary lesion, but following 2 days the terminal degeneration was apparent. 3. Postsynaptic spines, dendrites and even their cell bodies show edematic changes caused by the degeneration of postsynaptic counterpart. 4. Astrocytic territories, including perivascular processes forming glial limitans of blood-brain barrier, exhibit remarkable expansion. 5. Oligoglia and astroglia are actively engaged in the removal of degenerated elements. 6. Active forms of microglia were increased. 7. The observed results may represent typical ultrastructural alteration pattern within neuropil following the degeneration of certain input axon terminals.

  • PDF

An Exploratory Study on the Development of a Healthcare Smart Clothing for Measurement of Body Composition (체성분 측정용 스마트 의류 개발의 가능성 탐색)

  • Moon, Hui-Sung;Cho, Hyun-Seung;Park, Sun-Hyung;Lee, Joo-Hyeon;Cha, Kee-Chul;Shin, Sun-Young;Jung, Hyo-Il
    • Science of Emotion and Sensibility
    • /
    • v.10 no.3
    • /
    • pp.383-391
    • /
    • 2007
  • We have developed and evaluated a smart clothing system for the measurement of body composition in real time. Two kinds of experimental clothes were developed in this study to investigate the effects of textile electrodes on the measurements. As long as the wearer maintained same posture, the magnitudes of impedance was measured identically even though he got into the clothing again. Moreover we found the clothing could measure the impedance of each body segment.

  • PDF

Optical Properties with Arc Tube Structure of Ceramic Metal-Halide Lamps (세라믹 메탈할라이드 램프의 아크튜브 구조에 따른 광학적 특성)

  • Kim, Woo-Young;Jang, Hyeok-Jin;Yang, Jong-Kyung;Park, Hyung-Jun;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.378-379
    • /
    • 2009
  • High intensity metal halide discharge lamp performance, specifically the generated luminous flux and light color content, depends critically on the arc tube design. Factors influencing the design and consequent lamp efficacy include : lamp size, geometry, arc tube composition, fill chemistry, electrode design and excitation modes. Shaping of Polycrystalline Alumina(PCA) can be realized by conventional ceramic processes. Several processes are applied nowadays. Well-known in the ceramic high pressure field for decades are the pressing and the extrusion method. Newly developed slurry and precious forming technologies give the one-body seamless tubes, which improve thickness uniformity and lighting performance. Now, we reported some optical properties with different arc tube structures of ceramic metal halide lamps.

  • PDF

PZT membrane Piezoelectric Traveling Wave Motor

  • xin, Shen-De;an, Zhang-Bao;Lu jinan-guo;qing, Yang-Gen;yuan, Wang-Wei
    • Journal of the Korean Vacuum Society
    • /
    • v.6 no.S1
    • /
    • pp.89-95
    • /
    • 1997
  • A new type of piexoelectric membrane traveling wave motor has been designed and forbricated. The small motor is composed by the stator which is the combination of annular/circular membrane and metal elastic base using as the common electrode at some time and the rotor which is placed on the metal elastic body. Thus the motor structure is simple and easy to fabricate. The material of a piezoelectric membrane is fabricated by sol-gel method or wear-down method. A piezoelectric traveling wave motor has been fabricated with the stator diameter 8mm The total thickness of the stator is 350$\mu$m. Under the alternative excitation voltage 10-12V the revolving speed of the rotor is more than 100RPM.

  • PDF

Spray Characteristics of Electrostatic Pressure-Swirl Nozzle for Burner Application

  • Laryea, Gabriel Nii;No, Soo-Young
    • 한국연소학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.16-23
    • /
    • 2002
  • Electrostatic pressure-swirl nozzle for practical oil burner application has been designed. The charge injection method has been used in this design, where the nozzle consists of a sharp pointed tungsten wire as a charge injector and the nozzle body grounded. The spray characteristics of the nozzles have been investigated by using an insulating liquid, i.e. kerosene without active surface agent. Breakup length of liquid decreased with an increase in applied voltage and injection pressure, while the spray angle increased with an increased in both applied voltage and injection pressure. An empirical equations have been suggested to predict the breakup length for electrostatic pressure-swirl atomizer. The experimental result was within the range of the predicted equations. The SMD decreased between the ranges of 2.8 ${\sim}$ 33% when the conventional nozzle was compared to the electrostatic with -10 kV applied to the electrode at a radial distance from 5 to 20 mm.

  • PDF

Pattern Recognition of Dynamic Resistance and Real Time Quality Estimation (동저항 패턴 인식 및 실시간 품질 평가)

  • 조용준;이세헌
    • Proceedings of the KWS Conference
    • /
    • 2000.04a
    • /
    • pp.303-306
    • /
    • 2000
  • Quality estimation of the weld has been one of the important issues in RSW which is a main process of the sheep metal fabrication in auto-body industry, It was well known that among the various welding process variables, dynamic resistance has a close relation with nugget formation. With this variable, it is possible to estimate the weld quality in real time. In this study, a new quality estimation algorithm is developed with the primary dynamic resistance measured at welding machine timer. For this, feature recognition method of Hopfield neural network is used. Primary resistance patterns are vectorized and classified with five patterns. The network trained by these patterns recognizes the dynamic resistance pattern and estimates the weld quality Because the process variable monitored at the primary circuit is used, it is possible to apply this system to real time application without any consideration of electrode wear or shunt effect.

  • PDF

Direct Numerical Simulation of an Electro-Rheological Channel Flow (ER 유체의 채널유동에 대한 직접수치해석)

  • Cho, Sang-Ho;Choi, Hyoung-Gwon;Yoo, Jung-Yul
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.72-80
    • /
    • 2004
  • Steady flow of an ER (electro-rheological) fluid in a two-dimensional electrode channel is studied by using FEM. Hydrodynamic interactions between the particles and the fluid are calculated by solving the Navier-Stokes equation combined with the equation of motion for each particle, where the multi-body electrostatic interaction is described by using point-dipole model. Motion of the particles in the ER fluid is elucidated in conjunction with the mechanisms of the flow resistance and the increase of viscosity. The ER effects have been studied by varying the Mason number and volume fraction of particles. These parameters have an influence on the formation of the chains resulting in the changes of the fluid velocity and the effective viscosity of ER fluids.

A Model of a Simplified Mammography Geometry for Breast Cancer Imaging with EIT (전기임피던스 단층촬영법을 위한 단순화된 매모그래피 구조의 모델)

  • Choi, Myoung-Hwan
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.221-226
    • /
    • 2006
  • Electrical impedance tomography (EIT) is a technique for determining the electrical conductivity and permittivity distribution within the interior of a body from measurements made on its surface. One recent application area of the EIT is the detection of breast cancer by imaging the conductivity and permittivity distribution inside the breast. The present "gold standard" for breast cancer detection is X-ray mammography, and it is desirable that EIT and X-ray mammography use the same geometry. This paper presents a forward model of a simplified mammography geometry for EIT imaging. The mammography geometry is modeled as a rectangular box with electrode arrays on the top and bottom planes. A forward model for the electrical impedance imaging problem is derived for a homogeneous conductivity distribution and Validated by experiment using a phantom tank.

  • PDF