• 제목/요약/키워드: Electrochemical Impedance

검색결과 899건 처리시간 0.023초

Monitoring of Degradation Process of Commercial ME Tapes under High Humidity Environment by AC Impedance Techniques

  • Take, Seisho;Shimanuki, Akiko;Itoi, Yasuhiko;Okuyama, Masaru
    • Corrosion Science and Technology
    • /
    • 제3권5호
    • /
    • pp.194-197
    • /
    • 2004
  • The corrosion resistance of several kind of ME (Metal Evaporated) tape has been investigated both in mild sulfuric acid solution and NaCl solution by electrochemical impedance spectroscopy. It was found that the degradation of ME tapes was accelerated with increasing the concentration of sulfuric acid. There was no significant change in corrosion resistance when the concentration of NaCl was under 3.5 wt%. However, the impedance value decreased when the concentration of NaCl was up to 10 wt%. The degradation of backside of ME tapes was also investigated by AC impedance measurements. The results showed that the impedance behavior of backside plastic film changed with the concentration of sulfuric acid even at the beginning of immersion, implying the changing of the permeability for the backside of ME tapes. It was also found that the corrosion resistance of DVC (Digital Video Cassette) ME tape was better that that of Hi-8mm ME tapes in sulfuric acid solutions. Also, the backside of DVC ME tape showed better water resistance than that of Hi8 ME tapes.

전기화학적 전력 기기의 모델링을 위한 저가의 임피던스 분광 시스템의 개발 (Development of the Low Cost Impedance Spectroscopy System for Modeling the Electrochemical Power Sources)

  • 이주형;최우진
    • 전력전자학회논문지
    • /
    • 제13권1호
    • /
    • pp.46-54
    • /
    • 2008
  • 본 논문에서는 연료전지나 배터리 및 슈퍼커패시터 등의 전기화학적 전력기기의 임피던스 모델링에 적합한 저가의 임피던스 분광 시스템을 설계하고 구현하였다. 제안된 시스템은 간단한 센서회로 및 상용 DAQ(Data Acquisition) Board와 강력한 HMI(Human-Machine Interface)를 지원하는 그래픽 언어인 LabVIEW 소프트웨어를 이용하여 구성되었고 고가의 EIS(Electrochemical Impedance Spectroscopy) 장비를 대체하여 널리 사용될 수 있을 것으로 기대된다. 또한, 제안된 시스템에서는 Lock-in Amplifier를 이용함으로써 노이즈(Noise)가 많은 환경에서도 측정 주파수 성분의 정확한 측정이 가능하게 하였다. 제안된 시스템을 이용하여 Ballard Nexa 1.2kW PEM 연료전지 스택의 주파수별 임피던스를 측정하였고, 이를 바탕으로 한 등가 임피던스 모델도 제안된다. 제시된 모델과 개발된 장비의 유용함은 리플전류에 의한 연료전지 스택의 교류 손실 측정을 통해 증명된다.

전기화학적 활성과 내구성이 높은 Ti/IrO2/Ta2O5 전극 제조 (Fabrication of Ti/IrO2/Ta2O5 Electrode with High Electrochemical Activity and Long Lifetime)

  • 김다은;유재민;이용호;박대원
    • 한국물환경학회지
    • /
    • 제33권1호
    • /
    • pp.34-39
    • /
    • 2017
  • Under a corrosive environment, electrodes that are applied in the water-treatment system need not only very high electrochemical activity for fast reactions, but also high durability for cost saving. Therefore, the fabrication condition of iridium electrodes was examined to produce a more durable iridium electrode in this study. Tantalum was selected as a binder to enhance the durability of the iridium electrode. Investigation of the weight ratio between the catalyst and the binder to improve electrochemical activity was performed. Also, to compare the effect of the different coating amounts of the catalyst, the results of CV (Cyclic Voltammetry) and EIS (Electrochemical Impedance Spectroscopy) were discussed. Furthermore, an ALT(Accelerated Lifetime Test) was designed and applied to the electrodes to determine the conditions for highly durable electrode fabrication.

Li Ion Diffusivity and Improved Electrochemical Performances of the Carbon Coated LiFePO4

  • Park, Chang-Kyoo;Park, Sung-Bin;Oh, Si-Hyung;Jang, Ho;Cho, Won-Il
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권3호
    • /
    • pp.836-840
    • /
    • 2011
  • This study examines the effects of a carbon coating on the electrochemical performances of $LiFePO_4$. The results show that the capacity of bare $LiFePO_4$ decreased sharply, whereas the $LiFePO_4$/C shows a well maintained initial capacity. The Li ion diffusivity of the bare and carbon coated $LiFePO_4$ is calculated using cyclic voltammetry (CV) to determine the correlation between the electrochemical performance of $LiFePO_4$ and Li diffusion. The diffusion constants for $LiFePO_4$ and $LiFePO_4$/C measured from CV are $6.56{\times}10^{-16}$ and $2.48{\times}10^{-15}\;cm^2\;s^{-1}$, respectively, indicating considerable increases in diffusivity after modifications. The Li ion diffusivity (DLi) values as a function of the lithium content in the cathode are estimated by electrochemical impedance spectroscopy (EIS). The effects of the carbon coating as well as the mechanisms for the improved electrochemical performances after modification are discussed based on the diffusivity data.

전기화학 바이오센서의 전극물질로 응용을 위한 열분해 탄소의 제작 및 특성 연구 (Fabrication and Characterization of Pyrolyzed Carbon for Use as an Electrode Material in Electrochemical Biosensor)

  • 이정아;황성필;곽주현;박세일;이승섭;이광철
    • 대한기계학회논문집A
    • /
    • 제31권10호
    • /
    • pp.986-992
    • /
    • 2007
  • This paper presents the fabrication and characterization of carbon films pyrolyzed with various photoresists for bioMEMS applications. To verify the usefulness of pyrolyzed carbon films as an electrode material in an electrochemical biosensor developed by the authors, interactions between avidin and biotin on the pyrolyzed carbon film were studied via electrochemical impedance spectroscopy based on electrostatic interactions between avidin and negatively-charged ferricyanide. The pyrolyzed carbon films were characterized using a surface profiler, a precision semiconductor parameter analyzer, a nanoindentor, scanning electron microscopy, and atomic force microscopy. Amine conjugated biotin was immobilized on the electrode using EDC/NHS as crosslinkers after $O_2$ plasma treatment to enhance functional groups on the carbon electrode pyrolyzed at $1000^{\circ}C$ with AZ9260. The detection of avidin binding with different concentrations in a range of 0.75 nM to $7.5\;{\mu}M$ to the pyrolyzed carbon electrode modified with biotin was carried out by measuring the electrochemical impedance change. The results show that avidin binds to the biotin on the electrode not by non-specific interaction but by specific interaction, and that EIS successfully detects this binding event. Pyrolyzed carbon films are a promising material for miniaturization, integration, and low-cost fabrication in electrochemical biosensors.

Volatile Organic Compound Specific Detection by Electrochemical Signals Using a Cell-Based Sensor

  • Chung, Sang-Gwi;Kim, Jo-Chun;Park, Chong-Ho;Ahn, Woong-Shick;Kim, Yong-Wan;Choi, Jeong-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • 제18권1호
    • /
    • pp.145-152
    • /
    • 2008
  • A cell-based in vitro exposure system was developed to determine whether oxidative stress plays a role in the cytotoxic effects of volatile organic compounds (VOCs) such as benzene, toluene, xylene, and chlorobenzene, using human epithelial HeLa cells. Thin films based on cysteine-terminated synthetic oligopeptides were fabricated for immobilization of the HeLa cells on a gold (Au) substrate. In addition, an immobilized cell-based sensor was applied to the electrochemical detection of the VOCs. Layer formation and immobilization of the cells were investigated with surface plasmon resonance (SPR), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS). The adhered living cells were exposed to VOCs; this caused a change in the SPR angle and the VOC-specific electrochemical signal. In addition, VOC toxicity was found to correlate with the degree of nitric oxide (NO) generation and EIS. The primary reason for the marked increase in impedance was the change of aqueous electrolyte composition as a result of cell responses. The p53 and NF-${\kappa}B $ downregulation were closely related to the magnitude of growth inhibition associated with increasing concentrations of each VOC. Therefore, the proposed cell immobilization method, using a self-assembly technique and VOC-specific electrochemical signals, can be applied to construct a cell microarray for onsite VOC monitoring.

마멸 전극 기법과 교류 임피던스법으로 연구한 스테인리스강의 합금원소(Cr, Mo, N)가 재부동태 특성에 미치는 영향 (Effects of Alloying Elements(Cr, Mo, N) on Repassivation Characteristics of Stainless Steels Studied by the Abrading Electrode Technique and A.C Impedance Spectroscopy)

  • 함동호;김석원;이재봉
    • 전기화학회지
    • /
    • 제3권4호
    • /
    • pp.211-218
    • /
    • 2000
  • 마멸전극기법과 교류 임피던스법으로 스테인리스강의 합금원소, Cr, Mo, N가 합금의 재부동태 특성에 미치는 영향을 조사하였다. Fe-Cr, Fe-Cr-Mo, 304, 304LN, 316, 316LN등의 스테인리스강을 시편으로 사용하였으며 각 합금의 부동태 피막의 전기화학적 특성은 in-situ시험 기법인 d.c와 a.c전기화학적 기법을 각각 이용하였다 스테인리스강이 국부부식에 대하여 강한 저항성을 가지려면 부식 환경에서도 치밀한 부동태 피막을 유지해야 하고 피막의 파괴가 발생하더라도 재부동태 속도가 빨라야 하기 때문에 합금원소가 시간에 따른 재부동태 전류밀도와 재부동태 속도에 미치는 영향을 마멸 전극 시험법과 교류 임피던스 시험법으로 알아보았다. 부동태 피막의 안정성, 재부동태 속도 그리고 합금원소 사이의 관계를 규명하기 위하여 실험결과를 분석하였다.

고압 배터리 팩의 임피던스 스펙트럼 측정용 휴대용 임피던스 분광기 (A Portable Impedance Spectroscopy Instrument for the Measurement of the Impedance Spectrum of High Voltage Battery Pack)

  • 굴 라힘;최우진
    • 전력전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.192-198
    • /
    • 2021
  • The battery's State of Health (SOH) is a critical parameter in the process of battery use, as it represents the Remaining Useful Life (RUL) of the battery. Electrochemical Impedance Spectroscopy (EIS) is a widely used technique in observing the state of the battery. The measured impedance at certain frequencies can be used to evaluate the state of the battery, as it is intimately tied to the underlying chemical reactions. In this work, a low-cost portable EIS instrument is developed on the basis of the ARM Cortex-M4 Microcontroller Unit (MCU) for measuring the impedance spectrum of Li-ion battery packs. The MCU uses a built-in DAC module to generate the sinusoidal sweep perturbation signal. Moreover, it performs the dual-channel acquisition of voltage and current signals, calculates impedance using a Digital Lock-in Amplifier (DLA), and transmits the result to a PC. By using LabVIEW, an interface was developed with the real-time display of the EIS information. The developed instrument was suitable for measuring the impedance spectrum of the battery pack up to 1000 V. The measurement frequency range of the instrument was from 1 hz to 1 Khz. Then, to prove the performance of the developed system, the impedance of a Samsung SM3 battery pack and a Bexel pouch module were measured and compared with those obtained by the commercial instrument.

염료흡착 시간에 따른 염료감응형 태양전지의 출력 특성 및 내부 임피던스 분석 (Analyses of the Output Characteristics and the Change of Internal Impedance of Dye-sensitized Solar Cell According to the Adsorption Time)

  • 김희제;이정기;서현웅;손민규;신인영;안태풍;김진경
    • 전기학회논문지
    • /
    • 제59권1호
    • /
    • pp.102-107
    • /
    • 2010
  • Dye-sensitized solar cell (DSC) has been expected to be an alternative to the conventional silicon solar cell due to simple manufacturing process and low fabrication casts. In order to improve productivity of DSC, we attempted to optimize the required time of the adsorption process. According to the change in the adsorption time from 1 to 24h, We analyzed the output characteristics and the change of internal impedance. As a result, The outputs of DSC were continuously increased until 12h of the adsorption time and remained the same after that. Also, We reconfirmed this result that 12h was optimum adsorption by the analysis of the electrochemical impedance spectroscope because the internal impedance was similar to the output.

임피던스 복소캐패시턴스 분석법의 이론 및 응용 (Complex Capacitance Analysis of Impedance Data and its Applications)

  • 장종현;오승모
    • 전기화학회지
    • /
    • 제13권4호
    • /
    • pp.223-234
    • /
    • 2010
  • 본 총설에서는 캐패시터적인 특성을 가지는 다공성 전극의 전기화학특성 분석에 활용되는 임피던스의 복소캐패시턴스 분석법(complex capacitance analysis)의 이론 및 응용에 대해 정리하였다. 이론적으로 캐패시터적인 특성을 갖는 전기화학시스템에 대해 캐패시턴스허수부 도시를 활용하면 효과적인 해석이 가능함이 제시되었다. 또한, 복소캐패시턴스 분석법은 다공성 탄소 재료/전극의 EDLC 특성, 미세기공 내부의 이온전도 특성, 고분자전해질연료전지의 촉매층 이온저항 등의 분석에 효과적으로 적용될 수 있음이 검증되었다.