Measurement and Analysis of Rodent Biological Signals using Telemetry System (원격측정장치를 이용한 설치류의 생체신호 측정 및 분석)

  • Kim, Chang-Hwan;Hur, Gyeong-Haeng
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.6
    • /
    • pp.1159-1165
    • /
    • 2011
  • Telemetry techniques of rats have been used for assessing safety pharmacology of drugs and chemicals. Biological signals including blood pressure and heart rate measured under anesthesia were significantly different from those obtained under normal conditions. The stress of restraint in awake animals can also affect the accuracy of physiological evaluation. This paper details the surgery required to allow key cardiovascular parameters to be determined. The telemetric measurement of cardiovascular parameters such as blood pressure, heart rate, electrocardiograph(ECG) established. We carried out the continuous monitoring of cardiovascular parameters using the telemetry system in F344 rats. During the measurement, no significant changes were observed in the heart rate and blood pressure. ECG signals and body temperature were also constant during the measurement of biological signals. With the results of this study, we conclude that this telemetry system can be applied usefully for the assesment of biological parameters in the rats.

Development of Oriental-Western Fusion Patient Monitor by Using the Clip-type Pulsimeter Equipped with a Hall Sensor, the Electrocardiograph, and the Photoplethysmograph (홀센서 집게형 맥진기와 심전도-용적맥파계를 이용한 한양방 융합용 환자감시장치 개발연구)

  • Lee, Dae-Hui;Hong, Yu-Sik;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.4
    • /
    • pp.135-143
    • /
    • 2013
  • The clip-type pulsimeter equipped with a Hall sensor has a permanent magnet attached in the "Chwan" position to the center of a radial artery. The clip-type pulsimeter is composed of a hardware system measuring voltage signals. These electrical bio-signals display pulse rate, non-invasive blood pressure, respiratory rate, pulse wave velocity (PWV), and spatial pulse wave velocity (SPWV) simultaneously measured by using the radial artery pulsimeter, the electrocardiograph (ECG), and the photoplethysmograph (PPG). The findings of this research may be useful for developing a oriental-western biomedical signal storage device, that is, the new and fusion patient monitor, for a U-health-care system.

The CDA-based System Design and Implementation for the Exchange of ECG Reports Between Heterogeneous Systems (이기종간 심전도 판독지 교환을 위한 CDA에 기반한 시스템 설계 및 구현)

  • 전명주;이창건;최진욱;김인영;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.415-419
    • /
    • 2004
  • As the medical environment field has been facilitated by the rapid development of the information technologies and ubiquitous healthcare service based on network, the exchange of medical information between hospitals become more and more important. However, although most electrocardiograph vendors have provided digital modalities and their ECG data management systems, these were proprietary and not compatible with each other due to multiplicity of vendor specific formats and lack of open ECG data standards. Therefore, we aim to design and develop the ECG management system for archiving, saving, searching, viewing and transferring ECG data and the diagnostic reports. And the system is based on Clinical Document Architecture (CDA) developed by HL7 and DICOM Waveform Standard for the exchange of the structured diagnostic reports and the transfer of ECG data.

Implementation of Wearable Heart Activity Monitoring System having Modified Bipolar Electrode and Correlation Analysis with Clinical Electrocardiograph(ECG) (수정된 바이폴라 전극을 갖는 착용형 심장활동 모니터링 시스템 구현 및 임상 심전도와의 상관관계 분석)

  • Lee, Kang-Hwi;Lee, Jeong-Whan;Lee, Young-Jae;Kim, Kyeong-Seop;Yang, Heui-Koung;Shin, Kun-Su;Lee, Myoung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1102-1108
    • /
    • 2008
  • Wearable physiological signal monitoring systems are regarded as an important sensing unit platforms in ubiquitous/mobile healthcare application. In this paper, we suggested the modified bipolar electrodes implemented on the portable heart activity monitoring system, which minimized the distance of electrodes formed on a attachable pad. The proposed electrode configuration is useful in mobile measurement environments, but has a disadvantage of reduced amplitude of the heart action potential. In order to overcome the shortcoming of the suggested electrode configuration, we implemented the amplifying circuit to increase the signal-gain and decrease the artifacts. For evaluations, we analyzed the specificity of measured cardiography using the proposed electrodes through the comparing of heart activity monitoring system with standard clinical ECG(lead2) by pearson correlation coefficients. The result showed that the average correlation coefficient is $0.903{\pm}0.036,\;0.873{\pm}0.072$ at V3, V4 chest lead position, respectively. Thus, the modified bipolar electrode is quite suitable to monitor the electrical activity of the heart in the situation of the mobile environment, and could be considered having high similarity with standard clinical ECG.

Characteristics of Pulse Wave Velocity by the Simultaneously Measured ECG Waveform and Hall Device Radial Artery Waveform (ECG 파형과 홀소자 맥진파형으로 동시 측정한 맥파전달속도 특성 연구)

  • Yoo, Jae-Young;Choi, Suel-Gi;Kim, Dam-Bee;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.4
    • /
    • pp.136-141
    • /
    • 2012
  • In the this research, two simultaneous peaks of radial artery pulse wave and ECG pulse wave measured by using clip-type pulsimeter and ECG were investigated in order to analyze pulse wave velocity. The measured value of a pulse wave velocity is about 5~7 m/s, it is proved one new method to measure an exact value of pulse wave velocity more than the typical biomedical signal monitoring system. This result implies that data measured by the oriental medical diagnosis apparatus as pulsimeter is clinically used in future.

Development of ECS-NIBP-$SpO_2$ Patient Monitoring System (ECG-NIBP-$SpO_2$ 환자감시장치 개발)

  • Kim, N.H.;Shin, W.H.;Lee, G.K.;Ra, S.W.;Kim, G.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.129-130
    • /
    • 1998
  • In this paper, We designed the ECG-NIBP-$SpO_2$ patient monitor. This production can measure Electrocardiograph, Heart Rate, Noninvasive Blood Pressure, and Oxygen Saturation for Noninvasive Mehod and can display each information. These informations were implemented by the electrodes of ECG part, the cuff of NIBP module and the finger probe with light sensor of $SpO_2$ without injection of needle or catheter. In addition, We developed a new analysis algorithm and measurement technique for NIBP and $SpO_2$ to observe patient's conditions correctly.

  • PDF

Development of a Portable Digital Electrocardiograph(ECG) measurable with Gel-less Metal Electrodes (젤리스 금속 전극으로 측정가능한 휴대용 디지털 심전도계의 개발)

  • Nam, Young-Jin;Park, Kwang-Min
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1903-1907
    • /
    • 2013
  • Heart condition should be observed for long periods of time because it does not appear abnormal all the time. However, there are many difficulties checking our health for a long time due to its size, operation of equipment, and cost. To solve these problems, an electrocardiograms(ECG), specially interfacing three gel-less metal electrodes for low cost portable applications, is designed and implemented. Gel-less metal electrodes are used for ECG monitoring system instead of gel-type electrodes that can cause skin rashes and itching problem. The whole ECG system consists of two parts-analog and digital circuits. The analog measurement circuit that has a 18*25mm size is made up of op-amps maintaining a sufficiently high common-mode noise rejection and passive elements of SMD type. Analog heart signal is converted to digital stream suitable for display on a TFT-LCD by an 8-bit microcontroller. The size of the completed ECG system is 25*80*50mm and its weighing is about 150g, which is small enough to be easily used. Therefore, the implemented ECG system can be used as a portable one.

Electrocardiogram Signal Compression with Reconstruction via Radial Basis Function Interpolation Based on the Vertex

  • Ryu, Chunha;Kim, Tae-Hun;Kim, Jungjoon;Choi, Byung-Jae;Park, Kil-Houm
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Patients with heart disease need long-term monitoring of the electrocardiogram (ECG) signal using a portable electrocardiograph. This trend requires the miniaturization of data storage and faster transmission to medical doctors for diagnosis. The ECG signal needs to be utilized for efficient storage, processing and transmission, and its data must contain the important components for diagnosis, such as the P wave, QRS-complex, and T wave. In this study, we select the vertex which has a larger curvature value than the threshold value for compression. Then, we reconstruct the compressed signal using by radial basis function interpolation. This technique guarantees a lower percentage of root mean square difference with respect to the extracted sample points and preserves all the important features of the ECG signal. Its effectiveness has been demonstrated in the experiment using the Massachusetts Institute of Technology and Boston's Beth Israel Hospital arrhythmia database.

Development of a 12 Channel Interpretive Electrocardiograph (12채널 해석 심전계 시제품 개발)

  • Lee, Byung-Chae;Hahm, Geon;Jun, Young-Il;Choi, Kwang-Chol;Choi, Keun-Ho;Kim, Won-Ky;Kim, Jun-Soo;Jeong, Ki-Sam;Lee, Jeong-Whan;Lee, Myoung-Ho;Wright, George;Cochlan, David
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.411-414
    • /
    • 1997
  • This paper describes the design guideline, methodology and general specification of the developed 12 channel interpretive electrocardiograph. The developed 12 channel electrocardiograph consists of main module, patient module, DSP module, interface module, power/battery module, TFT color LCD and thermal recorder. The control panel of the system has full keyboard, rotate/push button, function key and unctional indicators. The graphic user interface program conveniently allows user to record, setup, store, manage ECGs. A variety of system configurations give it ability to make user favorable environment. This system also has a resting adult's ECG analysis program. The developed system and program will be continusely evolved using a database of clinically correlated ECGs.

  • PDF

Heart Rate Variability on Telephone types and IOD of Conversation while Driving (도로주행 중 휴대전화 수신시 핸드폰 형태와 대화난이도에 따른 심전도 변화)

  • Lee, Kyung-Tae;Jang, Phil-Sik;Kim, Ki-Hyun;Im, Jung-Bin;Lee, Dong-Hyun
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2005.05a
    • /
    • pp.554-559
    • /
    • 2005
  • It seems to be dangerous to use a cellular phone while driving since it increases driver's mental stress and makes driver's reaction time slow. This study is to investigate driver's psycho-physiological responses on mobile telephoning while driving. Among the three experimental factors (mobile-phone types, message IODs over mobile-phone, road types), only the message IODs over mobile-phone changed R-R intervals of electrocardiograph significantly. This result suggests that the regulations on the mobile telephoning while driving be changed.