• Title/Summary/Keyword: Electrocardiogram compression

Search Result 18, Processing Time 0.026 seconds

2D ECG Compression Method Using Sorting and Mean Normalization (정렬과 평균 정규화를 이용한 2D ECG 신호 압축 방법)

  • Lee, Gyu-Bong;Joo, Young-Bok;Han, Chan-Ho;Huh, Kyung-Moo;Park, Kil-Houm
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.193-195
    • /
    • 2009
  • In this paper, we propose an effective compression method for electrocardiogram(ECG) signals. 1-D ECG signals are reconstructed to 2-D ECG data by period and complexity sorting schemes with image compression techniques to Increase inter and intra-beat correlation. The proposed method added block division and mean-period normalization techniques on top of conventional 2-D data ECG compression methods. JPEG 2000 is chosen for compression of 2-D ECG data. Standard MIT-BIH arrhythmia database is used for evaluation and experiment. The results show that the proposed method outperforms compared to the most recent literature especially in case of high compression rate.

  • PDF

ECG Compression and Transmission based on Template Matching (템플릿 매칭 기반의 심전도 압축 전송)

  • Lee, Sang-jin;Kim, Sang-kon;Kim, Tae-kon
    • Journal of Internet Computing and Services
    • /
    • v.23 no.1
    • /
    • pp.31-38
    • /
    • 2022
  • An electrocardiogram(ECG) is a recoding of electrical signals of the heart's cyclic activity and an important body information for diagnosing myocardial rhythm. Large amount of information are generated continuously and a significant period of cumulative signal is required for the purpose of diagnosing a specific disease. Therefore, research on compression including clinically acceptable lossy technique has been developed to reduce the amount of information significantly. Recently, wearable smart heart monitoring devices that can transmit electrocardiogram(ECG) are being developed. The use of electrocardiogram, an important personal information for healthcare service, is rapidly increasing. However, devices generally have limited capability and power consumption for user convenience, and it is often difficult to apply the existing compression method directly. It is essential to develop techniques that can process and transmit a large volume of signals in limited resources. A method for compressing and transmitting the ECG signals efficiently by using the cumulative average (template) of the unit waveform is proposed in the paper. The ECG is coded lovelessly using template matching. It is analyzed that the proposed method is superior to the existing compression methods at high compression ratio, and its complexity is not relatively high. And it is also possible to apply compression methods to template matching values.

Verification of Effectiveness of Wearing Compression Pants in Wearable Robot Based on Bio-signals (생체신호에 기반한 웨어러블 로봇 내 부분 압박 바지 착용 시 효과 검증)

  • Park, Soyoung;Lee, Yejin
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.2
    • /
    • pp.305-316
    • /
    • 2021
  • In this study, the effect of wearing functional compression pants is verified using a lower-limb wearable robot through a bio-signal analysis and subjective fit evaluation. First, the compression area to be applied to the functional compression pants is derived using the quad method for nine men in their 20s. Subsequently, functional compression pants are prepared, and changes in Electroencephalogram (EEG) and Electrocardiogram (ECG) signals when wearing the functional compression and normal regular pants inside a wearable robot are measured. The EEG and ECG signals are measured with eyes closed and open. Results indicate that the Relative alpha (RA) and Relative gamma wave (RG) of the EEG signal differ significantly, resulting in increased stability and reduced anxiety and stress when wearing the functional compression pants. Furthermore, the ECG analysis results indicate statistically significant differences in the Low frequency (LF)/High frequency (HF) index, which reflect the overall balance of the autonomic nervous system and can be interpreted as feeling comfortable and balanced when wearing the functional compression pants. Moreover, subjective sense is discovered to be effective in assessing wear fit, ease of movement, skin friction, and wear comfort when wearing the functional compression pants.

Electrocardiogram Signal Compression with Reconstruction via Radial Basis Function Interpolation Based on the Vertex

  • Ryu, Chunha;Kim, Tae-Hun;Kim, Jungjoon;Choi, Byung-Jae;Park, Kil-Houm
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.13 no.1
    • /
    • pp.31-38
    • /
    • 2013
  • Patients with heart disease need long-term monitoring of the electrocardiogram (ECG) signal using a portable electrocardiograph. This trend requires the miniaturization of data storage and faster transmission to medical doctors for diagnosis. The ECG signal needs to be utilized for efficient storage, processing and transmission, and its data must contain the important components for diagnosis, such as the P wave, QRS-complex, and T wave. In this study, we select the vertex which has a larger curvature value than the threshold value for compression. Then, we reconstruct the compressed signal using by radial basis function interpolation. This technique guarantees a lower percentage of root mean square difference with respect to the extracted sample points and preserves all the important features of the ECG signal. Its effectiveness has been demonstrated in the experiment using the Massachusetts Institute of Technology and Boston's Beth Israel Hospital arrhythmia database.

Compression of Electrocardiogram Using MPE-LPC (MPE-LPC를 이용한 심전도 신호의 압축)

  • 이태진;김원기;차일환;윤대희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.28B no.11
    • /
    • pp.866-875
    • /
    • 1991
  • In this paper, multi pulse excited-linear predictive coding (MPE-LPC), where the correlation eliminated residual signal is modeled by a few pules, is shown to be effective for the compression of electrocardiogram (ECG) data, and a more efficient scheme for a faithful reconstruction of ECG is proposed. The reconstruction charateristic of QRS's and P.T waves is improved using the adaptive pulse allocation (APA), and the compression ratio (CR) can be changed by controlling the mumber of modeling pulses. The performance of the proposed method was evaluated using 10 normal and 10 abnormal ECG data. The proposed method had a better performance than the variable threshold amplitude zone time epoch coding (AZTEC) algorithm and the scan-along polygonal approximation (SAPA) algorithm with the same CR. With the CR in kthe range of 8:1 to 14:1, we could compress ECG data efficiently.

  • PDF

Optimal Selection of Wavelet Coefficients for Electrocardiograph Compression

  • Del Mar Elena, Maria;Quero, Jose Manuel;Borrego, Inmaculada
    • ETRI Journal
    • /
    • v.29 no.4
    • /
    • pp.530-532
    • /
    • 2007
  • This paper presents a simple method to implement a complete on-line portable wireless holter including an electrocardiogram (ECG) monitoring, processing, and communication protocol. The proposed algorithm significantly reduces the hardware resources of threshold estimation for ECG compression, using the standard deviation updated with each new input signal sample. The new method achieves superior performance in terms of hardware complexity, channel occupation and memory requirements, while keeping the ECG quality at a clinically acceptable level.

  • PDF

2D ECG Compression Using Optimal Sorting Scheme (정렬과 평균 정규화를 이용한 2D ECG 신호 압축 방법)

  • Lee, Kyu-Bong;Joo, Young-Bok;Han, Chan-Ho;Huh, Kyung-Moo;Park, Kil-Houm
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.4
    • /
    • pp.23-27
    • /
    • 2009
  • In this paper, we propose an effective compression method for electrocardiogram (ECG) signals. 1-D ECG signals are reconstructed to 2-D ECG data by period and complexity sorting schemes with image compression techniques to increase inter and intra-beat correlation. The proposed method added block division and mean-period normalization techniques on top of conventional 2-D data ECG compression methods. JPEG 2000 is chosen for compression of 2-D ECG data. Standard MIT-BIH arrhythmia database is used for evaluation and experiment. The results show that the proposed method outperforms compared to the most recent literature especially in case of high compression rate.

Curvature Based ECG Signal Compression for Effective Communication on WPAN

  • Kim, Tae-Hun;Kim, Se-Yun;Kim, Jeong-Hong;Yun, Byoung-Ju;Park, Kil-Houm
    • Journal of Communications and Networks
    • /
    • v.14 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • As electrocardiogram (ECG) signals are generally sampled with a frequency of over 200 Hz, a method to compress diagnostic information without losing data is required to store and transmit them efficiently on a wireless personal area network (WPAN). In this paper, an ECG signal compression method for communications onWPAN, which uses feature points based on curvature, is proposed. The feature points of P, Q, R, S, and T waves, which are critical components of the ECG signal, have large curvature values compared to other vertexes. Thus, these vertexes were extracted with the proposed method, which uses local extrema of curvatures. Furthermore, in order to minimize reconstruction errors of the ECG signal, extra vertexes were added according to the iterative vertex selectionmethod. Through the experimental results on the ECG signals from Massachusetts Institute of Technology-Beth Israel hospital arrhythmia database, it was concluded that the vertexes selected by the proposed method preserved all feature points of the ECG signals. In addition, it was more efficient than the amplitude zone time epoch coding method.

Performance Evaluation of ECG Compression Algorithms using Classification of Signals based PQSRT Wave Features (PQRST파 특징 기반 신호의 분류를 이용한 심전도 압축 알고리즘 성능 평가)

  • Koo, Jung-Joo;Choi, Goang-Seog
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.4C
    • /
    • pp.313-320
    • /
    • 2012
  • An ECG(Electrocardiogram) compression can increase the processing speed of system as well as reduce amount of signal transmission and data storage of long-term records. Whereas conventional performance evaluations of loss or lossless compression algorithms measure PRD(Percent RMS Difference) and CR(Compression Ratio) in the viewpoint of engineers, this paper focused on the performance evaluations of compression algorithms in the viewpoint of diagnostician who diagnosis ECG. Generally, for not effecting the diagnosis in the ECG compression, the position, length, amplitude and waveform of the restored signal of PQRST wave should not be damaged. AZTEC, a typical ECG compression algorithm, is validated its effectiveness in conventional performance evaluation. In this paper, we propose novel performance evaluation of AZTEC in the viewpoint of diagnostician.

Adaptive Sampling for ECG Detection Based on Compression Dictionary

  • Yuan, Zhongyun;Kim, Jong Hak;Cho, Jun Dong
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.608-616
    • /
    • 2013
  • This paper presents an adaptive sampling method for electrocardiogram (ECG) signal detection. First, by employing the strings matching process with compression dictionary, we recognize each segment of ECG with different characteristics. Then, based on the non-uniform sampling strategy, the sampling rate is determined adaptively. As the results of simulation indicated, our approach reconstructed the ECG signal at an optimized sampling rate with the guarantee of ECG integrity. Compared with the existing adaptive sampling technique, our approach acquires an ECG signal at a 30% lower sampling rate. Finally, the experiment exhibits its superiority in terms of energy efficiency and memory capacity performance.