• Title/Summary/Keyword: Electrocardiogram change

Search Result 65, Processing Time 0.022 seconds

Design of a Stress Measurement System for State Recognition of Game Addicts

  • Park, Myeong-Chul;Jung, Hyon-Chel;Kim, Tae-Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.6
    • /
    • pp.87-93
    • /
    • 2017
  • In this paper, we design a small low power single channel ECG(Electrocardiogram) system of Chest Belt type with fiber-type electrodes to measure emotional state change of game addict. HRV(Heart Rate Variability) is analyzed through heart rate signal measurement and the psychological stress state is judged by using it. And it verifies its effectiveness through prototype. First, we design HR measurement module through low power MCU(Micro Controller Unit) and implement prototype level measurement system. The results showed that the difference between the addiction group and the general group was confirmed and that the system was effective. The result of this study can be used for health management such as reduction of stress of the user through music and breathing that lowers the stress by detecting the stress state of the general person or the chronic ill person.

Extracting Heart Rate Variability from a Smartphone Camera

  • Lenskiy, Artem A.;Aitzhan, Yerlan
    • Journal of information and communication convergence engineering
    • /
    • v.11 no.3
    • /
    • pp.216-222
    • /
    • 2013
  • It is known that blood circulation in human body causes the skin tone to change concurrently with heartbeats. A number of apps have been developed to measure the heartbeat using smartphone camera; however, no any further analysis is performed. In this paper we propose an algorithm that detects heartbeats from the phone's camera and further extracts the heart rate variability (HRV). We compare the HRV extracted from the camera with the HRV extracted from the electrocardiogram. We estimated a number of commonly used HRV characteristics and compared them. Our results show that smartphone camera leads to slightly overestimated characteristics although the difference in extracted HRV signals is negligible. As a consequence we suggest that a smartphone camera can be employed in a quick heart diagnosis and diagnosis of autonomic nervous system.

Correlation of Axillary Artery Pressure and Phase of Esophageal Impedance in Chickens

  • Nakajima, Isao;Kuwahira, Ichiro;Hori, Shuho;Mitsuhashi, Kokuryo
    • Journal of Multimedia Information System
    • /
    • v.9 no.2
    • /
    • pp.161-170
    • /
    • 2022
  • Under General anesthesia with isoflurane, we insert a chicken's esophageal catheter into the near the left atrium. 1MHz radio wave was added to electrocardiogram electrodes of the esophagus, and the change of impedance (phase) was obtained by amplitude synchronous detection technique. At the same time, a thin tube is surgically inserted into the axillary artery to continuously measure blood pressure. The correlation between impedance (phase) and blood pressure was obtained. Both showed a very high correlation (R2=0.9665). It was also observed the waveform flowing from the left atrium into the left ventricle. When an individual infected with the avian influenza virus develops, the cytokine storms lead to hypotension earlier than the test for antigen-antibody reaction. In order to detect this, in the future, this impedance technique will be useful for screening individuals infected with avian influenza virus by measuring the blood pressure of chickens in cages in a non-contact manner using microwaves.

Reverse Takotsubo cardiomyopathy with left bundle branch block after anesthesia induction in a patient with subarachnoid hemorrhage: a case report

  • Choi, Eun Kyung;Kim, Jong-Hoon;Kim, Minhyun
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.2
    • /
    • pp.172-177
    • /
    • 2022
  • Takotsubo or reverse Takotsubo cardiomyopathy is a well-known cardiac complication of subarachnoid hemorrhage (SAH) that shows transient left ventricular wall motion abnormalities with electrocardiogram (ECG) changes. ST change followed by T inversion is a common ECG finding complicated with these disorders, left bundle branch block (LBBB) may be a potential ECG pattern which is seen. In this case, we describe the clinical profile and outcomes of a patient with LBBB and reverse Takotsubo cardiomyopathy after anesthetic induction, which was scheduled as an emergent external ventricular drainage after SAH. This is the first report of an LBBB pattern in reverse Takotsubo cardiomyopathy.

The Evaluation of Driver's Physiology Signal and Sensibility according to the Change of Speed and the Gap of Platoon on AHS (AHS에서 차량군의 속도와 거리 변화에 따른 운전자의 생체신호와 감성 평가)

  • Jeon, Yong-Uk;Park, Beom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.15-28
    • /
    • 2003
  • The one of the most important factors is the platoon design on developing AH3(Advanced Highway System), as it is related to traffic efficiency and drivers' safety. This study was evaluated that how much speed is comfortable for drivers and how long distance is appropriate for vehicular gap of platoon by measuring drivers' physiology signal and sensibility. A fixed-based AHS simulator was developed by using a real vehicle cockpit and the restructured part of Korean highway for human factors evaluation. The EEG(electroencephalogram), ECG (electrocardiogram) and GSR(Galvanic Skin Response) were measured for obtaining drivers' physiology signal according to the change of speed and gap. The brain wave(${\alpha},\;{\beta},\;{\delta},\;{\theta}$) by EEG, the response of the autonomic nervous system. the sympathetic and parasympathetic nervous system, by ECG, and relax-arousal situation by GSR were analyzed. The SD(Semantic Differential) method was also applied to evaluate drivers' sensibility by 5-grade evaluation scale with 96 adjectives. SSQ(Simulator Sickness Questionnaire) was used to measure the simulator sickness of pre and post driving, two times. As the results, drivers were comfortable with 120km/h speed of platoon and lam to 15m vehicular distance. The results of this study may differ from the adaption of the reality because of many parameters. However, the purpose of this study is show to significant results of the drivers' safety and the acceptability of human factors evaluation.

Changes of Behavioral and Physiological Responses Caused by Color Temperature

  • Lee, Young-Chang;Min, Yoon-Ki;Min, Byung-Chan;Kim, Boseong
    • Science of Emotion and Sensibility
    • /
    • v.18 no.2
    • /
    • pp.37-44
    • /
    • 2015
  • LED lighting has an advantage of adjusting color temperature. This change of color temperature may derive change in behavioral and physiological responses of the visual perception for indoor environments. This research examined the changes of behavioral and physiological responses caused by the color temperature. The environment was configured that the indoor temperature was 20 degrees centigrade or less as the perceived uncomfortable environment in winter. Then, the comfortable sensation vote (CSV) and the results of 3-back working memory test were measured as behavioral responses. In addition, the Electrodermal Activity (EDA) and Electrocardiogram (ECG) were measured as the responses of autonomics nervous system (ANS) in the three conditions of color temperature (red: 3862K, white: 5052K, blue: 11,460K). As a result, behavioral responses were not significant by the condition of color temperature, but the tendency of occupants' physiological relaxation appeared in the blue color temperature condition compared with the white color temperature condition. Although the color temperature of LED lighting might be a small factor in terms of the characteristics of indoor environment, it suggests that the color temperature could have an impact on the physiological changes in the parasympathetic nervous system.

ST-Segment Analysis of ECG Using Polynomial Approximation (다항식 근사를 이용한 심전도의 ST-Segment 분석)

  • Jeong, Gu-Young;Yu, Kee-Ho;Kwon, Tae-Kyu;Lee, Seong-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.8
    • /
    • pp.691-697
    • /
    • 2002
  • Myocardial ischemia is a disorder of cardiac function caused by insuficient blood flow to the muscle tissue of the heart. We can diagnose myocardial ischemia by observing the change of ST-segment, but this change is temporary. Our primary purpose is to detect the temporary change of the 57-segment automatically In the signal processing, the wavelet transform decomposes the ECG(electrocardiogram) signal into high and low frequency components using wavelet function. Recomposing the high frequency bands including QRS complex, we can detect QRS complex more easily. Amplitude comparison method is adopted to detect QRS complex. Reducing the effect of noise to the minimum, we grouped ECG by 5 data and compared the amplitude of maximum value. To recognize the ECG .signal pattern, we adopted the polynomial approximation partially and statistical method. The polynomial approximation makes possible to compare some ECG signal with different frequency and sampling period. The ECG signal is divided into small parts based on QRS complex, and then, each part is approximated to the polynomials. After removing the distorted ECG by calculating the difference between the orignal ECG and the approximated ECG for polynomial, we compared the approximated ECG pattern with the database, and we detected and classified abnormality of ECG.

The Effects of Qigong training on the cardiopulmonary functions and catecholamine levels after physical traning stress in untrained college students (‘내경일지선(內徑一指禪)’ 기공수련이 대학생의 운동부하 스트레스 후의 심폐기능 및 Catecholamine 변화에 미치는 영향)

  • Kim Jong-Woo;Oh Jae-Keun;Whang Wei-Wan
    • Journal of Oriental Neuropsychiatry
    • /
    • v.7 no.1
    • /
    • pp.39-48
    • /
    • 1996
  • This study was performed to investigate the effects of Qigong training after physical training stress in untrained college students For this study, 6 voluntary subjects(male 4, female 2) were chosen in untrained students of K University. they were trained by teachers during 6 weeks and tested just before Qingong training and after 6 weeks. Each subject was performed a treadmill exercise(model Q65, Quinton Co, U.S.A.) to the all-out state. During exercise stress test, electrocardiogram, heart rate were checked by stress test monitor(model Q4500, Quinton Co, U.S.A) and also oxygen uptake, maximal oxygen uptake analyzed continuously by automatic gas analysis(model QMC, Quinton Co, U.S.A). During physical training the serum were collected 3 times, pre-experimental rest time, and serum catecholamine were measured by HPLC.T-test of statistical analysis system was used in every experiment for statistical assessment. The results of T-test on these data were summarized as follow:1.Heart rate change during exercise stress test after Qigong training was shown more decreasing tendency than before training. Especially, heart rate change after Qigong training during resting periods was decreased significantly than before training.2. Oxygen uptake change during exercise stress test after Qigong training was shown more increasing tendency than before training, And also maximal oxygen uptake after Qigong training was shown more increasing tendency than before 6 weeks.3. Epinephrine level of after Qigong training was more decreased significantly than before training in all-out state. And norepinephrine level of after Qigong training was shown more decreasing tendency than before training in all-out state and after 30 minutes rest time. Above results indicate that Qigong training for 6 weeks could be effective to elevate the cardiopulmonary functions and diminish the stress responses of the physical stress.

  • PDF

Implementation and evaluation of the BCG measurement system for non-constrained health monitoring (무구속 건강모니터링을 위한 심탄도 계측 시스템 구현 및 평가)

  • Noh, Yun-Hong;Jeong, Do-Un
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.8-16
    • /
    • 2010
  • This research proposes measuring of BCG(ballistocardiogram) to monitor heart activities in a non-constrained environment, at home or work. Unlike with ECG, measuring BCG does not require the attachment of leads on the subject's body and allows signal measuring in a non-constrained state. It enables effective long-term monitoring of cardiac conditions. In this study a chair type BCG measurement system to continuous monitor the activity of the heart is implemented. The instrument consists of upper petal and ready for press of chair load cell sensor is attached to measure the change of the object's weight. In order to extract the output ballistic signal from the weight and force sensor signals. Beside the signal processing circuit for the digital conversion, the ballistic signal is detected using DAQ equipment. Signal processing algorithm including wavelet transforms for noise cancellation, template matching for normalization and peak detection in BCG is developed. ECG and BCG were concurrently measured to evaluate the performance of the system, and comparing the characteristics of the two signals verified the possibility of the system in non-constrained and nonconscious health monitoring.

Basic Study of Weaving Structure and Durability for Fabric-type ECG Sensor Design (직물형 ECG센서 설계를 위한 제직구조 및 내구성에 대한 기초연구)

  • Ryu, Jong-Woo;Jee, Young-Joo;Kim, Hong-Jae;Yoon, Nam-Sik
    • Textile Coloration and Finishing
    • /
    • v.23 no.3
    • /
    • pp.219-226
    • /
    • 2011
  • Recently, study of functional clothing for vital sensing is focused on improving conductivity and decreasing resistance, in order to enhance the electrocardiogram(ECG) sensing accuracy and obtained stable environmental durability on operation condition. In this study, four ECG fabrics that having different componnt yarns and weaving structures were produced to analyze their environmental durabilities and electric properties under general operation conditions including different physical and chemical stimulation. For outstanding electric properties and physical properties, the optimized ECG sensing fabric should consist of a fabric of 2 up 3 down twill structure containing 210de silver-coated conductive yarns and polyester yarn in warp and weft directions respectively. The selected fabric has $0.11{\Omega}$ which is relative lower resistance than otherwisely produced fabrics under ECG measurement condition. And it has 7% stable resistance changes under 25% strain and repeated strain.