• 제목/요약/키워드: Electrocardiogram Signals

검색결과 158건 처리시간 0.024초

비접촉 방식의 생체 신호 측정을 위한 도플러 레이더 시스템 (Doppler Radar System for Noncontact Bio-signal measurement)

  • 신재연;조성필;장병준;박호동;이윤수;이경중
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2009년도 정보 및 제어 심포지움 논문집
    • /
    • pp.357-359
    • /
    • 2009
  • In this paper, the 2.4GHz doppler radar system consisting of the doppler radar module and a baseband module were designed to detect heartbeat and respiration signal without direct skin contact. A bio-radar system emits continuous RF signal of 2.4GHz toward human chest, and then detects the reflected signal so as to investigate cardiopulmonary activities. The heartbeat and respiration signals acquired from quadrature signal of the doppler radar system are applied to the pre-processing circuit, amplification circuit, and the offset circuit of the baseband module. ECG(electrocardiogram) and reference respiration signals are measured simultaneously to evaluate the doppler radar system. As a result, the respiration signal of doppler radar signal is detected to 1m without complex digital signal processing. The sensitivity and calculated from I/Q respiration signal were $98.29{\pm}1.79%$, $97.11{\pm}2.75%$, respectively, and positive predictivity were $98.11{\pm}1.45%$, $92.21{\pm}10.92%$, respectively. The sensitivity and positive predictivity calculated from phase and magnitude of the doppler radar were $95.17{\pm}5.33%$, $94.99{\pm}5.43%$, respectively. In this paper, we confirmed that noncontact real-time heartbeat and respiration detection using the doppler radar system has the possibility and limitation.

  • PDF

블루투스-LE 기반 심전도/근전도/맥박 무선 모니터링 회로 및 시스템 구현 (Implementation of a Bluetooth-LE Based Wireless ECG/EMG/PPG Monitoring Circuit and System)

  • 이욱준;박형열;신현철
    • 전자공학회논문지
    • /
    • 제51권6호
    • /
    • pp.261-268
    • /
    • 2014
  • 본 논문에서는 저전력 블루투스인 블루투스-LE를 기반으로 하여 심전도, 근전도, 맥박 신호의 무선 모니터링 시스템을 설계 및 구현하였다. 심전도와 근전도 신호를 얻기 위한 센서 인터페이스 아날로그 회로부는 상용칩을 이용하여 설계 및 제작하였다. 저전력 블루투스 통신 모듈로는 Texas Instruments에서 제공하는 CC2540DK를 이용하였다. 2개의 CC2540DK를 사용하여 각각 Peripheral과 Central 노드 역할을 하도록 했다. Peripheral은 획득한 아날로그 생체신호를 ADC를 이용해 디지털 신호로 변환한 후 무선으로 Central로 전송하는 역할을 한다. Central은 Peripheral로부터 데이터를 수신한 후 UART 통신을 통해 PC로 전송한다. 전송된 생체신호는 그래픽 사용자 인터페이스를 통해 파형 또는 결과값의 형태로 표시된다. 이와 같은 시스템은 블루투스 4.0기반 무선 생체신호 모니터링 헬스케어 시스템에 적극 활용될 수 있을 것이다.

착용형 응급의료 경보시스템 구현에 관한 연구 (A Study on Wearable Emergency Medical Alarm System)

  • 김동완;백승화
    • 전기전자학회논문지
    • /
    • 제10권1호
    • /
    • pp.55-61
    • /
    • 2006
  • 현대 사회는 의료 기술의 발달로 인한 인간 수명의 연장과 핵가족화로 인하여 혼자 지내는 노인이 많아지면서 응급상황 발생시 신속한 의료서비스를 받지 못하는 경우가 많아지고 있다. 또한 대표적인 성인병인 심혈관질환과 뇌졸중 그리고 노인의 건강에 치명적인 낙상의 발생율도 높아지고 있는 추세이다. 본 논문에서는 심전도, 체온, 사용자의 움직임 등의 생체신호를 획득하고 획득된 생체신호를 분석하여 심혈관질환, 뇌졸중, 낙상 등의 응급상황 발생시 응급의료센터와 보호자에게 구조메시지를 전송할 수 있는 시스템을 제안하였다. 시스템은 크게 생체신호 획득부와 모바일부 두 부분으로 나눌 수 있다. 생체신호 획득부는 사용자에 따라 생체신호의 추가, 제거가 어렵다는 단점을 보완하기 위해 심전도, 체온, 가속도 센서 모듈로 모듈화 하여 구성하였다. 모바일부는 생체신호 획득부로부터 전송된 생체신호의 처리 및 응급상황시 메시지 전송, 생체신호의 디스플레이 역할을 수행하며, 생체신호 획득부에서 획득된 생체신호는 블루투스 모뎀을 통하여 모바일부로 전송된다. 또한 모바일부에서 처리된 신호는 802.11b 무선랜을 통하여 PC로 전송된다.

  • PDF

저전력 무선 생체신호 모니터링을 위한 심전도/근전도/뇌전도의 압축센싱 연구 (Study on Compressed Sensing of ECG/EMG/EEG Signals for Low Power Wireless Biopotential Signal Monitoring)

  • 이욱준;신현철
    • 전자공학회논문지
    • /
    • 제52권3호
    • /
    • pp.89-95
    • /
    • 2015
  • 무선 헬스케어 서비스에서 생체신호 모니터링 시스템의 전력소모를 효과적으로 감소시킬 수 있는 압축센싱 기법을 다양한 생체신호에 적용하여 압축률을 비교하였다. 압축센싱 기법을 이용하여 일반적인 심전도, 근전도, 뇌전도 신호의 압축과 복원을 수행하였고, 이를 통해 복원된 신호와 원신호를 비교함으로써, 압축센싱의 유효성을 판단하였다. 유사랜덤 행렬을 사용하여 실제 생체신호를 압축하였으며, 압축된 신호는 Block Sparse Bayesian Learning(BSBL) 알고리즘을 사용하여 복원하였다. 가장 산제된 특성을 가지는 근전도 신호의 최대 압축률이 10배로 확인되어 가장 높았으며, 심전도 신호의 최대 압축률은 5배였다. 가장 산제된 특성이 작은 뇌전도 신호의 최대 압축률은 4배였다. 연구된 심전도, 근전도, 뇌전도 신호의 압축률은 향후 압축센싱을 적용한 무선 생체신호 모니터링 회로 및 시스템 개발시 유용한 기초자료로 활용될 수 있다.

광전력 진폭변조와 ICA를 이용한 PPG 신호의 동잡음 제거 필터 설계 (Design of Filter to remove motion artifacts of PPG signal using Amplitude Modulation of Optical Power and Independent Components Analysis)

  • 이주원;이병로
    • 한국정보통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.691-697
    • /
    • 2013
  • 최근 IT+BT 융합 기술로 건강관리 및 응급의료 등을 위하여 U-헬스케어 단말 장치가 개발되고 상품화가 되고 있다. 이 단말기에서 측정하는 생체 신호들은 심전도, 체온, 산소포화도, 심박수, 호흡 등이며, 특히 이들 신호 중에 광용적맥파(PPG) 신호는 산소포화도와 심박수, 말초혈관 탄성도 등을 측정함에 있어 매우 중요한 신호이다. 그러나 이 PPG 신호는 환자 또는 사용자의 움직임에 따라 발생하는 동잡음의 영향에 의해 그 정밀도가 저하된다. 따라서 본 연구에서는 이러한 동잡음을 제거하기 위한 광변조 기법과 ICA 기법을 제안한다. 제안된 기법의 성능을 분석하기 위해 다양한 잡음을 인위적으로 가하여 실험하였으며, 실험 결과를 분석한 결과에서 제안된 기법이 기존의 적응 필터법 보다 우수한 성능을 보였다.

잡음이 포함된 측정 자료에 대한 신경망의 DNA 용액 조성비 예측 (Prediction of Composition Ratio of DNA Solution from Measurement Data with White Noise Using Neural Network)

  • 강경희;김민지;이효민
    • Korean Chemical Engineering Research
    • /
    • 제62권1호
    • /
    • pp.118-124
    • /
    • 2024
  • 신경망은 심전도 신호, 망막 영상, 지진파 등 잡음이 포함된 자료의 전처리 작업에 활용되고 있다. 그러나, 잡음의 전처리는 전산시간 증가, 원본 신호의 왜곡등의 문제점을 내포하고 있다. 본 연구에서는 잡음의 전처리 없이 측정 자료를 분석할 수 있는 신경망 구조를 연구하였다. 신경망의 학습 자료로써 잡음이 포함된 DNA 용액의 동역학적 거동을 선정하여, 해당 자료로부터 DNA 용액의 조성비를 예측하고자 하였다. DNA의 동역학 자료에 인위적으로 백색 잡음을 추가하여, 신경망의 예측에 대한 잡음의 영향을 알아보았다. 결과적으로, 잡음의 전처리 없이 O(1)의 신호 대 잡음비 자료로부터 O(0.01)의 오차로 용액의 조성비를 예측할 수 있었다. 이러한 연구 결과는 측정 잡음에 민감하게 영향 받을 수 있는 극미량의 유전병 또는 암세포와 관련된 DNA를 분석을 위한 핵심 인공지능 기술로 활용할 수 있다.

A Cell Phone-based ECG, Blood Pressure Monitoring System for Personal Healthcare Applications using Wireless Sensor Network Technology

  • Toh, Sing-Hui;Lee, Seung-Chul;Chung, Wan-Young
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2008년도 춘계종합학술대회 A
    • /
    • pp.505-508
    • /
    • 2008
  • Electrocardiogram (ECG) and blood pressure (BP) are main vital signs which are the standards in most medical settings in assessing the most basic body functions. Multi parameters are desired in providing more information for health professionals in order to detect or monitor medical problems of patients more precisely. This study urges us to develop a robust wireless healthcare monitoring system which has multiple physiological signs measurements on real time that applicable to various environments which integrates wireless sensor network technology and code division multiple access (CDMA) network with extended feature of locally standalone diagnosis algorithms that implemented in tell phone. ECG signal and BP parameter of the patients are routinely be monitored, processed and analyzed in details at cell phone locally to produce useful medical information to ease patients for tracking and future reference purposes. Any suspected or unknown patterns of signals will be immediately forwarded to hospital server using cell phone for doctors' evaluation. This feature enables the patients always recognize the importance of self-health checking so that the preventive actions can be taken earlier through this analytic information provided by this monitoring system because "Prevention is better than Cure".

  • PDF

다중레이트 필터링 기법을 이용한 맥파전달시간 추정 (Estimation of PTT (Pulse Transit Time) by Multirate Filtering Analysis)

  • 김현태;김정환;김경섭;이재호;이정환
    • 전기학회논문지
    • /
    • 제62권7호
    • /
    • pp.1020-1026
    • /
    • 2013
  • Multirate filtering process on the biological signals like Electrocardiogram (ECG) and Photoplethysmogram (PPG) can be defined as the digital signal processing algorithm in which the sampling rate varies to omit or interpolate the intermediate values between the sampled data. With this aim, we suggest a new multirate filtering algorithm by deleting the extraneous data to eliminate the unwanted degradations such as granular noise due to the usage of high sampling frequency and simultaneously to detect the fiducial features of ECG and PPG with reducing the complexity of resolving fiducial points such as R-peak, Pulse peak and Pulse Transit Time (PTT). After the experimental simulations performed, we can conclude the fact that we can detect the fiducial features of ECG and PPG signal in terms of R-peak, Pulse peak and PTT without the loss of accuracy even if we do not maintain the original sampling frequency.

소형화 및 저전력소모를 구현한 실시간 생체신호 측정기 개발 (A compact and low-power consumable device for continuous monitoring of biosignal)

  • 조정현;윤길원
    • 센서학회지
    • /
    • 제15권5호
    • /
    • pp.334-340
    • /
    • 2006
  • A compact biosignal monitoring device was developed. Electrodes for electrocardiogram (ECG) and a LED and silicon detector for photoplethysmogram (PPG) were used. A lead II type was arranged for ECG measurement and reflected light was measured at the finger tip for PPG. A single chip microprocessor (model ADuC812, Analog Device) controlled a measurement protocol and processed measured signals. PPG and ECG had a sampling rate of 300 Hz with 8-bit resolution. The maximum power consumption was 100 mW. The microprocessor computed pulse transit time (PTT) between the R-wave of ECG and the peak of PPG. To increase the resolution of PTT, analog peak detectors obtained the peaks of ECG and PPG whose interval was calculated using an internal clock cycle of 921.6 kHz. The device was designed to be operated by 3-volt battery. Biosignals can be measured for $2{\sim}3$ days continuously without the external interruptions and data is stored to an on-board memory. Our system was successfully tested with human subjects.

단계별 기저선 정렬을 이용한 ECG 신호에서 P파와 T파 검출 알고리즘 (P-Waves and T-Wave Detection Algorithm in the ECG Signals Using Step-by-Step Baseline Alignment)

  • 김정홍;이승민;박길흠
    • 한국멀티미디어학회논문지
    • /
    • 제19권6호
    • /
    • pp.1034-1042
    • /
    • 2016
  • The detection of P-waves and T-wave in the electrocardiogram signal analysis is an important issue. But the accuracy of the boundary detection algorithm is an insufficient level in the change of slow transition in the signal compared to the QRS complex. This study proposes an algorithm to detect P-wave and T-wave sequentially after determining local baseline using QRS complex. First, we detected the peak points based on local baseline and determined the onset and offset through the calculation of the area of the section. After modifying the baseline using detected waveform, we detected the other waveform in the same way and separated the P-wave and the T-wave based on the location. We used the PhysioNet QT database to evaluate the performances of the algorithm, and calculate the mean and the standard deviations. The experiment results show that standard deviations are under the tolerances accepted by expert physicians, and outperform the results obtained by the other algorithms.