• Title/Summary/Keyword: Electro-chemical degradation

Search Result 30, Processing Time 0.029 seconds

An Electro-Fenton System Using Magnetite Coated One-body Catalyst as an Electrode (일체형 산화철 촉매를 전극으로 하는 전기펜톤산화법)

  • Choe, Yun Jeong;Ju, Jeh Beck;Kim, Sang Hoon
    • Applied Chemistry for Engineering
    • /
    • v.29 no.1
    • /
    • pp.117-121
    • /
    • 2018
  • A stainless steel mesh was applied to the cathode of an electro-Fenton system. Methylene blue (MB) solution was chosen as the model waste water with non-biodegradable pollutants. For the model waste water, the degradation efficiency was compared among various SUS mesh cathodes with different surface treatments and magnetite coatings on them. With increasing amount of the magnetite coating on SUS mesh, the degradation efficiency also increased. The improved electro-catalytic characteristic was explained by the increased amount of in situ generated hydrogen peroxide near the cathode surface. Cyclic voltammetry data also showed improved electro-catalytic performance for SUS mesh with more magnetite coatings on them.

Characteristic Accelerated Aging Assessment for Coolant Rubber Hose of Automotive Radiator (자동차 냉각기 고무호스의 가속 노화거동 평가)

  • Kwak, Seung-Bum;Choi, Nak-Sam;Kang, Bong-Sung;Shin, Sei-Moon
    • Proceedings of the Korean Reliability Society Conference
    • /
    • 2006.05a
    • /
    • pp.27-31
    • /
    • 2006
  • Rubber hoses for automobile radiators are apt to degraded and thus failed due to the influence of contacting stresses of air and coolant liquid under thermal and mechanical loadings. The aging behaviors of the skin part of the hoses due to thermo-oxidative and electro-chemical stresses were experimentally analyzed. Through the thermo-oxidative aging test, it was shown that the surface hardness IRHD(International Rubber Hardness Degrees) of the rubber increased with a considerable reduction of failure strain as the aging time and temperature were large. On account of the penetration of coolant liquid into the skin part the weight of rubber specimens influenced by electro-chemical degradation (ECD) test increased, whereas their failure strain and IRHD hardness decreased. The hardness decreased further as the test site on the hose skin approached to the negative pole.

  • PDF

A Characterization on Organic Electro-luminescence (유기 전기 luminescence 다이오드 특성)

  • Lee, Han-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2007.11c
    • /
    • pp.165-169
    • /
    • 2007
  • Organic EL has been expected to adopt to a new styles of technology that make flat display after Tang & Vanslyke made food electric luminescence device in late 1980s. Their studies based on multi layer structure that consists of emitting layer and carrier transporting layer using proper organic material. In this study we made multi layer device using $Eu(TTA)_3(phen)$ as a luminescence material by PVD and investigate luminous properties of each device. But oxidization of organic layer by ITO, energy walls in both pole interface, contaminations of ITO surface, importance of protecting membrane, diffusive dimming of light to cathode organic layer, these causes of degradations are common facts of a macromolecule and micromolecule. We think these degradation caused by the impact of heat and electro-chemical factor, bulk effect and interface phenomenon, and raise a question.

  • PDF

A Research on Organic Electro-luminescence (유기 전기발광 소자에 관한 연구)

  • Lee, Han-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2005.10a
    • /
    • pp.82-85
    • /
    • 2005
  • Organic EL has been expected to adopt to a new styles of technology that make flat display after Tang & Vanslyke made good electric luminescence device in late 1980s. Their studies based on multi layer structure that consists of emitting layer and carrier transporting layer using proper organic material. In this study, we made multi layer device using $Eu(TTA)_3(phen)$ as a luminescence material by PVD and investigate luminous properties of each device. But oxidization of organic layer by ITO, energy walls in both pole interface, contaminations of ITO surface, importance of protecting membrane, diffusive dimming of light to cathode organic layer, these causes of degradations are common facts of a macromolecule and micromolecule. We think these degradation caused by the impact of heat and electro-chemical factor, bulk effect and interface phenomenon, and raise a question.

  • PDF

Experimental Studies on Comparison of Stress Corrosion Cracking Generation Due to Pipe Material Degradation in the Primary Stage of the Nuclear Power Plant (원전 1차 측 배관재질의 열화에 따른 응력부식균열 발생 비교 실험 연구)

  • Park, Kwang-Jin;Lee, Gyu-Young;Bae, Dong-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.108-113
    • /
    • 2007
  • In this report, stress corrosion cracking generation due to pipe material degradation in the primary stage of the nuclear power plant was investigated. Firstly, after artificially degrading the CF8A steel during 2, 4, and 6 months in actual temperature, $400^{\circ}C,$ assessed corrosion susceptibility of the degraded material following ASTM G5 standard. And next, the S.C.C. tests for the degraded material were conducted under the condition of $60^{\circ}C,$ 2wt.% H2BO3+Li70H solution, 0.8 oy. From the results, Corrosion rates linearly increased with degradation period and solution temperature increase. And both the raw material and the degraded materials were not failed in the S.C.C. test condition. In spite of long time test (about 3,900 hrs) under S.C.C. condition, surface pits or surface corrosion by the electro chemical reaction were not observed. And also, even though the nondestructive DCPD and ACPD methods were applied to on-line monitor the S.C.C. failure processes it was impossible because the surface pits and cracks were not generated.

  • PDF

Study on the Improvement of the Reliability of Al-Cu Connections in Power Distribution Systems(II) (송배전용 Al-Cu 접속금구의 신뢰도 향상에 관한 연구(II) 압축형 및 폭발용접형 접속금구의 내식성 비교)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.370-372
    • /
    • 2003
  • As there expands the usage of Al-Cu connections to interface aluminum and copper in power distribution systems, efforts to mitigate the mechanical, electrical or electro-chemical degradation are widely spreading. The explosive bending technology, in particular, has been thought as a countermeasure for the degradation. In this paper, electrochemical analysis and optical microscopic observation are carried out in order to compare the corrosion resistivities of the commercial compression type bimetallic sleeve and the explosion type bimetallic sleeve. The results show that the explosive bonding technology can prevent the interfacial corrosion caused by the formation of crevices and pits as well as from galvanic potential difference.

  • PDF

Fatigue Fracture Characteristics by Corrosion Degradation of 12Cr Alloy Steel (12Cr합금강의 부식열화에 의한 피로파괴 특성)

  • Jo, Seon-Yeong;Kim, Cheol-Han;Bae, Dong-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.6
    • /
    • pp.996-1003
    • /
    • 2001
  • In order to investigate the fatigue fracture characteristics by corrosion degradation of 12Cr alloy steel, both the fatigue characteristics in air of them artificially degraded during long period and the corrosion fatigue characteristics were experimentally evaluated in various environments which were determined from electro-chemical polarization tests. And also, their fracture mechanisms were analyzed and compared, fractographyically. From their results, the fracture mechanical characteristics of it artificially degraded during long period in the distilled water, 3.5 wt.% NaCl solution and 12.7wt.%(1M) Na$_2$SO$_4$solution of 25, 60 and 90$\^{C}$ did not show distinguishable difference comparing with non-corroded one in regardless of temperature and degradation period. It means that degradation of the material by just surface corrosion does not remarkably affect to fatigue crack growth. On the other hand, the crack growth rates by corrosion fatigue increased due to activity increase of corrosive factors such as OH(sub)-,Cl(sup)- and SO$_4$(sup)- at the crack tip with temperature increase. Therefore, the crack growth rates by corrosion fatigue were more faster than that in air of the artificially degraded specimen due to the such difference of crack growth mechanism.

An Experimental Analysis of the Ripple Current Applied Variable Frequency Characteristic in a Polymer Electrolyte Membrane Fuel Cell

  • Kim, Jong-Hoon;Jang, Min-Ho;Choe, Jun-Seok;Kim, Do-Young;Tak, Yong-Sug;Cho, Bo-Hyung
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.82-89
    • /
    • 2011
  • Differences in the frequency characteristic applied to a ripple current may shorten fuel cell life span and worsen the fuel efficiency. Therefore, this paper presents an experimental analysis of the ripple current applied variable frequency characteristic in a polymer electrolyte membrane fuel cell (PEMFC). This paper provides the first attempt to examine the impact of ripple current through immediate measurements on a single cell test. After cycling for hours at three frequencies, each polarization and impedance curve is obtained and compared with those of a fuel cell. Through experimental results, it can be absolutely concluded that low frequency ripple current leads to long-term degradation of a fuel cell. Three different PEMFC failures such as membrane dehydration, flooding and carbon monoxide (CO) poisoning that lead to an increase in the impedance magnitude at low frequencies are simply introduced.

SIMS Investigation of Black Cr Solar Selective Coatings (Black Cr 태양 선택흡수막의 SIMS 연구)

  • Lee, Kil-Dong
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.39-44
    • /
    • 2014
  • The elemental composition of electro-deposited black Cr solar selective coatings before and after heating in air by using secondary ion mass spectrometry (SIMS) was investigated for optical property analysis. In addition, black Cr selective coating exposed by solar radiation for 5 months was compared with heated sample. SIMS investigation shows that $OH^+$ bearing ions were related to a near surface region of CrOH and CrO compound. The optical degradation of this coating after heating at $500^{\circ}C$ reveals that diffusion of the Cu and Ni elements in substrate material, the chemical interactions adjacent to the interface, and the interface width broadening.

A study on Fabrication and Characterization of Organic Light-Emitting Diodes (유기 발광 다이오드의 제작 및 특성에 관한 연구)

  • Lee, Han-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2008.11b
    • /
    • pp.89-91
    • /
    • 2008
  • Organic EL has been expected to adopt to a new styles of technology that make flat display after Tang & Vanslyke made good electric luminescence device in late 1980s. Their studies based on multi layer structure that consists of emitting layer and carrier transporting layer using proper organic material. But oxidization of organic layer by ITO, energy walls in both pole interface, contaminations of ITO surface, importance of protecting membrane, diffusive dimming of light to cathode organic layer, these causes of degradations are common facts of a macromolecule and micro molecule. We think these degradation caused by the impact of heat and electro-chemical factor, bulk effect and interface phenomenon, and raise a question.

  • PDF