A complete high-frequency small-signal circuit model of a 40 Gb/s butterfly electroabsorption modulator integrated laser module is presented for the first time to analyze and optimize its electro-optic (E/O) response and reflection characteristics. An agreement between measured and simulated results demonstrates the accuracy and validity of the procedures. By optimizing the bonding wire length and the impedance of the coplanar waveguide transmission lines, the E/O response increases approximately 5% to 15% from 20 GHz to 33 GHz, while the signal injection efficiency increases from approximately 15% to 25% over 18 GHz to 35 GHz.
A programmable smart charger compatible to various load conditions is proposed in this paper. Since the proposed smart charger is compatible to various mobile devices having different rated voltage and power, it is convenient for carrying and easy to standardize many kinds of battery chargers. Moreover, since it uses the input impedance and built-in PMIC (Power management IC) of the load system to recognize the connection state and specifications of load system, hardware changes of load system is not only hardly necessary but it also features no addition communication cable and easy implementation. To confirm the validity of the proposed charger, the theoretical analysis and experiment results from a prototype compatible to three load conditions 5V/1A, 5V/2A and 12V/1A are provided.
1 mol% $Li_2O$ excess $0.9(Na_{0.52}K_{0.48})NbO_3-0.1LiTaO_3$ lead-free piezoelectric multilayer ceramic actuators were investigated to determine their aging properties. To reduce the thermal aging behavior, we applied a rectified unipolar electric field of 5 kV/mm to the specimen to accelerate the electric aging behavior. By employing a rectified unipolar electric field for the piezoelectric actuators, we could remove undesirable heating from the relaxation current in the motion of the ferroelectric domain. To accelerate the aging test, the applied electric fields had a frequency of 900 Hz. To have enough time for charging and discharging, we employed an accurate time constant to design the equivalent circuit model for the aging tester. To extract exact aging behavior, we measured the pseudo-piezoelectric coefficient before and after the aging process. We also measured the electro-mechanical coupling coefficient, the frequency-dependent dielectric permittivity, and the impedance to compare with fresh and aged specimen.
This paper describes of a mathematical and real experimental analysis for a walking robot which uses servo valve driven hydraulic actuator. Recently, many researchers are developing a walking robot based on hydraulic systems for the difficult and dangerous missions such as walking in the rough terrain and carrying a heavy load. In order to design and control a walking robot, the characteristics of the hydraulic actuators in the joint through the view point of walking such as controllability and backdrivability must be analyzed. A general mathematical model was used for analysis and proceeds to position and pressure changes characteristic of the input and backdrivability experiment. The result shows the actuator is a velocity source, had a high impedance, the output stiffness is high in contact with the rigid external force. So stand above the controller and instruments that complement the design characteristics can be seen the need to apply a hydraulic actuator in walking robot.
본 연구에서는 염료감응 태양전지의 상대전극으로써 다중벽 탄소나노튜브를 사용하여 전기화학적 특성에 미치는 열처리 효과에 대해 연구하였다. 다중벽 탄소나노튜브는 실리콘 기판위에 철 촉매를 사용하여 열화학 기상증착법으로 합성하였다. 직경이 다른 다중벽 탄소나노튜브를 각각 성장하여 두 개의 샘플을 준비하였고 질소 분위기의 RTA(rapid thermal annealing) system에서 $900^{\circ}C$ 온도로 1분간 열처리 하였다. 다중벽 탄소나노튜브의 구조적, 전기적, 전기화학적 특성은 FE-SEM, Raman spectroscopy, 2-point probe station, electrochemical impedance spectroscopy (EIS)을 이용하여 측정하였다. 라만 스펙트럼 분석에서 열처리 한 다중벽 탄소나노튜브의 I(D)/I(G) ratio는 상당히 감소한 것을 확인하였으며, 다중벽 탄소나 노튜브 표면과 전해질과의 산화 환원 반응 특성에서는 열처리 전보다 열처리 후의 전해질과의 산화 환원 반응 특성이 향상된 것을 알 수 있었다. 표면에서의 반응 저항 또한 열처리 후의 다중벽 탄소나노튜브가 더 낮은 값을 나타내었다. 그 결과, 열처리 후의 다중벽 탄소나노튜브를 상대전극으로 사용하였을 때의 전기화학적 특성이 더 좋은 것을 확인하였다.
색채 환경에 따라 인지반응의 상관관계를 분석한 결과가 다양한 산업분야에 적용되고 있다. 특히, 의학 분야에서 색채 환경기반 생체신호를 수집하여 환자 상태의 파악과 치료 그리고 뇌활동의 규명에 관련된 연구가 활발하게 진행되고 있다. 그러나 기존 연구들은 색채조명 또는 LED를 이용한 색채 환경을 구축하여 다양한 실험을 진행하고 있으나 다른 광원에 노출 되어 심리적인 영향을 주는 문제점을 갖고 있다. 따라서, 본 논문에서 제안하는 시스템은 HMD(Head-Mounted-Display)를 이용하여 피험자에게 완벽한 색채 환경조건을 제공하고자 한다. 그리고 인체반응정도 측정을 위해 기억력-주의력 테스트하는 동안 BMS(Bio-Medical-System)으로 생체정보를 수집하여 색채별 인체반응정도 측정뿐만 아니라 심리적인 변화에 대한 상관관계를 확인할 수 있는 시스템을 제안한다. 제안한 시스템을 통하여 수집하는 생체정보는 심전도(ECG), 호흡(Respiration), 산소포화도(SpO2), 임피던스(Bio-Impedance), 혈압(Blood-Pressure) 이며 데이터베이스에 저장한다. 이와함께, 인체의 인지반응을 측정하기위해 기억력-주의력 테스트는 앱으로 구현하여 색채 조건별 인지반응 정보를 측정하고 결과를 확인 할 수 있다. 제안한 시스템을 통하여 수집된 인체반응정보를 활용하여 생리학적 정보의 정량화하는 연구를 진행할 수 있으며, 색채 환경과 생리학적 정보의 상관관계를 분석하여 의학적 진단 및 치료에 응용이 될 것으로 기대한다. 향후 연구로 구축한 시스템을 통해 수집된 데이터를 분석 및 시각화 기능을 추가하고, 치매 질환의 예측 및 치료를 위한 시스템으로 확장하여 재활프로그램으로서의 유효성을 평가하고자 한다.
5.2GHz 중심 주파수를 갖는 Bragg reflector형 FBAR를 제작하여 주파수 응답 특성을 측정하고, 공진기 구조에서 각 층의 탄성 손실(acoustic loss)을 고려한 주파수 응답의 수치적 계산을 통해서 그 특성을 분석하였다. W과 $SiO_2$쌍을 선택하여 RF sputtering법으로 총 9층의 Bragg reflector를 제작하였고, 공진기의 압전층으로 pulsed dc 전원에 의한 sputtering법으로 AlN과 Al 전극을 증착하여 제작하였다. 제작된 공진기의 반사손실( $S_{11}$)은 중심주파수 5.38GHz에서 12dB이었고 직렬 공진 주파수( $f_{s}$)는 5.376GHz, 병렬 공진 주파수 ( $f_{p}$)는 5.3865GHz로 관찰되었다. 공진기의 성능지수인 유효 전기기계결합계수( $K_{ef{f^2}}$)값이 약 0.48%, 품질계수 ( $Q_{s}$) 값이 411이었다. 수치적으로 계산된 주파수 응답 특성으로부터 AlN 박막의 acoustic 상수들과 Bragg reflector의 반사계수를 도출한 결과 AlN 박막의 material acoustic impedance와 wave velocity는 AlN 고유의 값보다 감소되었으며, AlN 박막의 전기기계 결합계수( $K^2$)값은 c축 배향성 저하에 의해 매우 작은 값(0.49%)을 가졌다. 주파수 대역에서 Bragg reflector의 반사계수는 약 0.99966으로 계산되었으며 약 2.5 GHz에서 9.5 GHz까지의 넓은 반사대역을 나타내었다.다.었다.
Atmospheric Pressure Plasmas have pioneered a new field of plasma for biomedical application bridging plasma physics and biology. Biological and medical applications of plasmas have attracted considerable attention due to promising applications in medicine such as electro-surgery, dentistry, skin care and sterilization of heat-sensitive medical instruments [1]. Traditional approaches using electronic devices have limits in heating, high voltage shock, and high current shock for patients. It is a great demand for plasma medical industrial acceptance that the plasma generation device should be compact, inexpensive, and safe for patients. Microwave-excited micro-plasma has the highest feasibility compared with other types of plasma sources since it has the advantages of low power, low voltage, safety from high-voltage shock, electromagnetic compatibility, and long lifetime due to the low energy of striking ions [2]. Recent experiment [2] shows three-log reduction within 180-s treatment of S. mutans with a low-power palm-size microwave power module for biomedical application. Experiments using microwave plasma are discussed. This low-power palm-size microwave power module board includes a power amplifier (PA) chip, a phase locked loop (PLL) chip, and an impedance matching network. As it has been a success, more compact-size module is needed for the portability of microwave devices and for the various medical applications of microwave plasma source. For the plasma generator, a 1.35-GHz coaxial transmission line resonator (CTLR) [3] is used. The way of reducing the size and enhancing the performances of the module is examined.
압전복합체는 낮은 음향 임피던스와 높은 전기-기계 결합계수를 가지는 장점으로 인해 광대역 음향 트랜스듀서의 개발에 널리 활용되고 있으나, 구조의 복잡성으로 인해 이를 이용한 각종 트랜스듀서의 설계에 많은 제약이 있어왔다. 본 논문에서는 1-3형 압전복합체의 등가물성을 도출하여, 압전복합체와 동일한 특성을 가지는 균질한 단일 상의 물질로 대체하는 방법을 제안하였다. 압전복합체의 다양한 진동모드에서의 공진특성을 정확히 나타낼 수 있는 등가물성 도출을 위해 공진법과 유한 요소 해석법을 이용하였다. 제작한 1-3형 압전복합체 시편과 유한요소해석 모델의 주파수 특성을 비교하여 본 논문의 등가물성도출 방법의 타당성을 검증하였으며, 등가물성을 각 공진 모드별 단일상의 유한요소 해석 모델들에 적용하여 도출한 물성값의 정확성을 분석하였다.
본 논문에서는 비파괴검사용 고성능 결함탐상기를 위한 압전변환기를 구현하였다. 여기서는 압전변형상수와 전기기계 결합계수 등과 같은 주요 특성에 대한 설계 목표치를 먼저 정하고 유한요소해석을 이용하여 얻은 데이터를 설계 및 제작에 활용하였다. 시편을 이용한 실험 결과, 제작된 PZT 세라믹은 목표치들을 매우 잘 만족시키는 것으로 확인되었다. 이는 공진 주파수에서 매우 향상된 임피던스 특성과 초음파 발생 특성을 가지는 것으로 나타났다. 또한 새로운 압전변환기가 적용된 초음파 결함탐상기는 기존 탐상기보다 증가된 결함 검출이득을 제공한다. 따라서 새로운 결함탐상기는 초음파를 이용한 비파괴검사의 검사 신뢰성 향상에 크게 기여할 수 있을 것으로 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.