• 제목/요약/키워드: Electrification voltage

검색결과 35건 처리시간 0.02초

A Study of the Streaming Electrostatic Current in High Voltage - Large Power Transformer (초고압 대용량 변압기에서의 유동대전 현상에 관한 연구(전압무인가))

  • Park, Jae-Yun;Yun, Seung-Jin;Minari, Kogane;Lee, Duck-Chool;Kwak, Hee-Ro
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.176-179
    • /
    • 1990
  • In this paper, the pheonmena of flowing electrification is experimently studied in the model transformer of a super high voltage transformer. The current of natural terminal which is flowed by the flowing electrification is increased according to oil flow, but according to the oil temperature the current is decreased and the direction of the current is changed.

  • PDF

Dielectric Breakdown Voltage According to Flow Velocity and Temperature of Vegetable Oils (식물성절연유의 유동속도와 온도에 따른 절연파괴전압)

  • Choi, Sun-Ho;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • 제61권6호
    • /
    • pp.821-826
    • /
    • 2012
  • The streaming electrification process of vegetable insulating oils occurring when the oils contacted with solid material in a high power transformer circulation system seems to cause electrical discharge incidents and may cause failures. We therefore measured the dielectric breakdown voltage tendency of vegetable insulating oils flowing on the surface of the charging device with various velocity and temperature. First, the relation between the velocity and breakdown voltage tendency of vegetable oils, can be explained by volume effect and v-t effect. Second, experimental results show that applied voltage have little effect on dielectric breakdown voltage, when vegetable insulating oils used for large power transformer.

Studies on Electrostatic Propensity of Fabrics (직물대전성에 관한 연구)

  • 최병희;배도규
    • Journal of Sericultural and Entomological Science
    • /
    • 제27권2호
    • /
    • pp.54-63
    • /
    • 1985
  • This studies has been carried out how to effect on electrostafic propensity of synthetic fabrics by coating with 0.5% acrylic polymer solution which was previously developed by the author to improve anticrease nature of silk. The work conditions are: (A) Applied synthetic polymer was acrylic polymer 525, developed by the author. (B) Electrostatic voltage for various fabrics were carried out by Korea standard abrasion partner with Korea standard (KS K 0905) cotton, nylon, polyester and the self sample fabric. (C) Applied fabrics for the investigations were carried out by using abrasion partner with Korea standard (KS K 0905) cotton, nylon, polyester and the self sample fabric. (D) Electrostatic propensity investigations were carried out by use of sample as silk, nylon, polyester and acrylic fabrics, seperating before finish or after finish. (E) Washing after the finish or the original fabric was carried out by Korea standard method, KS K 0465. Through the investigations, he happened to find many interesting matters and the obtained results are as followings. 1. Electrostatic voltage for the finished fabrics increased more than their original silk, nylon, acrylic fabrics except polyester fabric. (See Table 5) 2. Electrostatic voltage for the finished polyester against K.S. polyester decreased remarkably than the original fabric test. 3. In spite of no problem on electrostatic propensity of silk, it showed high electrostatic voltage between the same nature fabric abrasion, because silk is very weak against abrasion and because the test method had been developed to be useful for only synthetic fabrics. 4. Electrostatic voltage increased more in case of abrasion between different nature of fabrics than the same nature of fabrics. 5. Electrostatic voltage of each fabric increased by repeat of wash. 6. Many investigation data were followed with Contact Electrification Series Principle, another word, the farther each other located fabric on the series abrasion was, the higher electrostatic voltage. (See Fig. 6) 7. Such investigation gives warning of use on the mix fiber spinning service as far as concern with electrification. 8. It may also call attention for such increase of electrification in case any finishing of silk textile.

  • PDF

Optimization and Application Research on Triboelectric Nanogenerator for Wind Energy Based High Voltage Generation (정전발전 기반 바람에너지 수확장치의 최적화 및 고전압 생성을 위한 활용 방안)

  • Jang, Sunmin;Ra, Yoonsang;Cho, Sumin;Kam, Dongik;Shin, Dongjin;Lee, Heegyu;Choi, Buhee;Lee, Sae Hyuk;Cha, Kyoung Je;Seo, Kyoung Duck;Kim, Hyung Woo;Choi, Dongwhi
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.243-248
    • /
    • 2022
  • As the scope of use of portable and wearable electronic devices is expanding, the limitations of heavy and bulky solid-state batteries are being revealed. Given that, it is urgent to develop a small energy harvesting device that can partially share the role of a battery and the utilization of energy sources that are thrown away in daily life is becoming more important. Contact electrification, which generates electricity based on the coupling of the triboelectric effect and electrical induction when the two material surfaces are in contact and separated, can effectively harvest the physical and mechanical energy sources existing in the surrounding environment without going through a complicated intermediate process. Recently, the interest in the harvest and utilization of wind energy is growing since the wind is an infinitely ecofriendly energy source among the various environmental energy sources that exist in human surroundings. In this study, the optimization of the energy harvesting device for the effective harvest of wind energy based on the contact electrification was analyzed and then, the utilization strategy to maximize the utilization of the generated electricity was investigated. Natural wind based Fluttering TENG (NF-TENG) using fluttering film was developed, and design optimization was conducted. Moreover, the safe high voltage generation system was developed and a plan for application in the field requiring high voltage was proposed by highlighting the unique characteristics of TENG that generates low current and high voltage. In this respect, the result of this study demonstrates that a portable energy harvesting device based on the contact electrification shows great potential as a strategy to harvest wind energy thrown away in daily life and use it widely in fields requiring high voltage.

Review of the earthing method of the copper wire shield of 66kV feeder cable in tunnel area (터널 구간 66kV 급전선 차폐층 접지 시공 방법에 관한 검토)

  • Kwon Sam-Young;Kim Do-Won;Ahn Young-Boon;Park Hyun-Jun
    • Proceedings of the KSR Conference
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.1474-1479
    • /
    • 2004
  • In electrification of the Honam line, the grounding method of the copper wire shield of 66kV feeder cable was disputed. This paper describes that the review of the proper earthing method(one-side earthing or both-side earthing) under consideration of the site condition and the acceptability of the induction voltage of the shield on the end of the cable.

  • PDF

Design and Parallel Operation of 30 kW SiC MOSFET-Based High Frequency Switching LLC Converter With a Wide Voltage Range for EV Fast Charger (전기자동차 급속충전기용 넓은 전압 범위를 갖는 30kW급 SiC MOSFET 기반 고속 스위칭 LLC 컨버터 설계 및 병렬 운전)

  • Lee, Gi-Young;Min, Sung-Soo;Park, Su-Seong;Cho, Young-Chan;Lee, Sang-Taek;Kim, Rae-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • 제27권2호
    • /
    • pp.165-173
    • /
    • 2022
  • The electrification trend of mobility increases every year due to the development of power semiconductor and battery technology. Accordingly, the development and distribution of fast chargers for electric vehicles (EVs) are in demand. In this study, we propose a design and implementation method of an LLC converter for fast chargers. Two 15 kW LLC converters are configured in parallel to have 30 kW rated output power, and the control algorithm and driving sequence are designed accordingly and verified. In addition, the improved power conversion efficiency is confirmed through zero-voltage switching (ZVS) of the LLC converter and reduction of turn-off loss through snubber capacitors. The implemented 30 kW LLC converters show a wide output voltage range of 200-950 V. Experiments applying various load conditions verify the converter performance.

Eloctrostatic Electrification Properties of Silicone Rubber in the Presence of Pt Flame Retardant (백금 난연제에 의한 실리콘 고무의 정전기 대전 특성)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • 제35권5호
    • /
    • pp.494-498
    • /
    • 2022
  • In this study, SiO2 20 phr, ATH 70 phr, and platinum flame retardant were mixed with raw silicone rubber and -10 kV was applied to measure electrostatic charge attenuation voltage, surface resistance, and volume resistance, and the following conclusions were obtained. When the platinum flame retardant was 0 phr, the humidity 74.6% and the temperature was 21.8℃, the potential was half-reduced to 0.63 kV, 0.57 kV, and 0.44 kV when the applied voltage was changed from -10 kV to -8 kV, and the time halved to 50% was increased to 2.40 seconds, 2.47 seconds, and 2.61 seconds. It was confirmed that as the platinum flame retardant increased from 0.1 to 0.3 phr, the potential half-reduced to 0.67 kV, 0.60 kV, and 0.595 kV decreased, and the charge potential attenuation time half-reduced to 50% decreased to 3.44 seconds, 1.78 seconds, and 1.60 seconds. It was confirmed that the surface resistance increased as the humidity decreased, and the volume resistance decreased as the platinum flame retardant increased.

A Study on the new method of electrostatic elimination in oil flowing pipe. (세관을 흐르는 절연유의 유동대전에 의한 대전전하의 제전방법에 관한 연구)

  • Minari, Kogane;Park, Jae-Yun;Lee, Duck-Chool;Hwang, Myung-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 대한전기학회 1990년도 추계학술대회 논문집 학회본부
    • /
    • pp.129-131
    • /
    • 1990
  • When insulating oil is flowed through a pipe, the electrostatic charge in the oil will be increased. Using inflammability oil, an electrostatic phenomena which may cause significantly problems as explosion must be circumvented by some methods. In this paper we made a new electrode which was applied AC field to the flowing oil for reducing electrostatic charge. Before we developed the new method of an electrostatic elimination, the electrification experiment was performed by using the same electrode which was supplied DC voltage to realize electrified conditions. As a result of this study, the effect of the electrostatic elimination could be observed.

  • PDF

A Study on the Separation of Mixed Waste Plastics by Trioboelectrification (마찰대전을 이용한 혼합폐플라스틱 분리에 관한 연구)

  • Lee, Jong-Ho;Shin, Jin-Hyuk;Kim, Doo-Hyun;Kim, Jang-Woo;Lee, Jae-Keun
    • Proceedings of the KSME Conference
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.538-543
    • /
    • 2000
  • The purpose of this study is to develope electrostatic separation system for recycling of mixed waste plastics. The electrostatic separation system is designed and investigated the separation efficiency for separating of mixed waste plastics. Electrostatic separation system consisted of a tribocharger, separator (two electrode), collector (5 tray) and controller (positive/negative high voltage power supply). The tribocharger is a fluidized bed using tribo-electrification mechanism between particles and particles. In experimental results, the tribocharger of the fluidized bed was more effective separation efficiency. It showed the purity of $85{\sim}99\;%$ and the recovery of $80{\sim}98\;%$ from the powder of mixed plastics such as LDPE, HDPE, PP, PS, PET and PVC. Especially, In the separation experiment of Polyvinylchloride(PVC) which generates hazardous hydrogen chloride gas in case of the combustion. its purity was over 99 % and recovery was over 95 %.

  • PDF

Comparison of Intelligent Charging Algorithms for Electric Vehicles to Reduce Peak Load and Demand Variability in a Distribution Grid

  • Mets, Kevin;D'hulst, Reinhilde;Develder, Chris
    • Journal of Communications and Networks
    • /
    • 제14권6호
    • /
    • pp.672-681
    • /
    • 2012
  • A potential breakthrough of the electrification of the vehicle fleet will incur a steep rise in the load on the electrical power grid. To avoid huge grid investments, coordinated charging of those vehicles is a must. In this paper, we assess algorithms to schedule charging of plug-in (hybrid) electric vehicles as to minimize the additional peak load they might cause. We first introduce two approaches, one based on a classical optimization approach using quadratic programming, and a second one, market based coordination, which is a multi-agent system that uses bidding on a virtual market to reach an equilibrium price that matches demand and supply. We benchmark these two methods against each other, as well as to a baseline scenario of uncontrolled charging. Our simulation results covering a residential area with 63 households show that controlled charging reduces peak load, load variability, and deviations from the nominal grid voltage.