• Title/Summary/Keyword: Electrical wire

Search Result 1,524, Processing Time 0.029 seconds

A Study on Temperature Variation of Contact Wire by De-icing System (해빙시스템에 의한 전차선의 온도변화에 관한 연구)

  • Ahn, Byeong-Lib;Lee, Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.9
    • /
    • pp.69-74
    • /
    • 2008
  • The frost and freezing on contact wire in winter is a very serious problem Shocks at the mechanical interface of the collecting strips of the pantograph and the contact wire. Extra electrical resistance, which may affect quality of current collection at the contact wire / collecting strips of pantograph interface. De-icing system is to melt frost or freezing in contact wire. The principle of do-icing system is to melt frost or ice by Joule heat of contact wire impedance. The temperature of the contact wire was increased with increasing the current. But temperature of contact wire was decreased with increasing the velocity of the wind.

Influence of the Electrical Conductivity of Dielectric on WEDM of Sintered Carbide

  • Kim, Chang-Ho;Kruth, Jean-Pierre
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1676-1682
    • /
    • 2001
  • This work deals with the electrical conductivity of dielectric and cobalts percentage on output parameters such as metal removal rate and surface roughness value of sintered carbides cut by wire-electrical discharge machining (WEDM). To obtain a precise workpiece with good quality, some extra repetitive finish cuts along the rough cutting contour are necessary, Experimental results show that increases of cobalt amount in carbides affects the metal removal rate and worsens the surface quality as a greater quantity of solidified metal deposits on the eroded surface. Lower electrical conductivity of the dielectric results in a higher metal removal rare as the gap between wire electrode and workpiece reduced. Especially, the surface characteristics of rough-cut workpiece and wire electrode were analyzed too. To obtain a good surface equality without crack, 4 finish-cuts were necessary reducing fille electrical energy and the offset value.

  • PDF

Aging Analysis of Catenary Wires in Accordance with Temperature Changes for a Long Period of Time (장기간 온도변화에 따른 전차선로 전선류의 노후도 분석)

  • Cho, Nam-Hee;Oh, Wan-Shik;Kim, Jae-moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.9
    • /
    • pp.1590-1596
    • /
    • 2016
  • In this paper, catenary wires were analyzed aging through the experiment about a new product and a test sample in accordance with temperature changes from long-term use. In case of the contact wire, the maximum load was reduced within 7% and the tensile strength showed a reduced within 6.7% compared with a new reference standard $110mm^2$. 19 Strands of messenger wire have a little more than a standard value, but result data on tensile test were less than the reference value about stranded wire. Also parts among 49 strands of dropper was found to be smaller than the reference value and it appeared greatly increasing intensity as toward the center of the strand.

Effect of Winding Coil Diameter on AC Insulation Breakdown Voltage of Polyamideimide/Nanosilica Wire

  • Park, Jae-Jun;Woo, Myung-Ha;Lee, Jae-Young;Han, Se-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • v.17 no.4
    • /
    • pp.231-234
    • /
    • 2016
  • The AC insulation breakdown voltage was investigated for seven types of winding coils made of polyamideimide (PAI), flexural PAI (nanosilica 5 wt%) and anti-corona PAI (nanosilica 15 wt%) wires with various winding coil diameters of φ5, φ15 and φ25 mm. The winding coil was made of enameled wire with an enamel thickness of 30~50 μm, and the rectangular copper wire had a thickness of 0.77~ to 0.83 mm and width of 1.17~ to 1.23 mm, respectively. The insulation breakdown voltages of the original PAI coils with diameters of φ5, φ15 and φ25 mm were 7.30, 6.58, and 5.95 kV, respectively, and those values decreased as the winding coil diameter increased, regardless of the wire types.

Experimental Study on The Propagation Characteristics of Lightning Surge According to Variation of Wire Length (배선 길이 변화에 따른 뇌서지 전파 특성에 대한 실험 연구)

  • Seo Ho-Joon;Rhie Dong-Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.12
    • /
    • pp.616-619
    • /
    • 2004
  • Electrical circuits with semiconductor are very weak against lightning surge. The surge protective devices for electronic circuit and AC power lines are becoming more widely used. To achieve effective method of surge protection, there are needs for correlation between lightning surge and indoor wire length or installation height of indoor wire. The aim of this present work is to investigate the propagation characteristics of lightning surge according to variation of wire length. As a consequence, the maximum voltage at the end of the open wire in proportion to length of indoor wire. Therefore this result may be raw data for establishment of surge protection system.

The effect of coating wire on the performance of wire electrical discharge machining (코팅와이어가 와이어 방전가공 특성에 미치는 영향)

  • 임세환;김준현;김주현
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.177-185
    • /
    • 2004
  • The machining performance of wire electrical discharge machining(WEDM), such as cutting speed, surface roughness and straightness depend on the electrode, and the machining parameters are diverse and affect each other. Therefore operator must have a lot of experiences of the parameter for the better machining performance in WEDM. An approach to minimize the time for determining of parameters setting is proposed. Based on the Taguchi method, the significant factors affecting the machining performance are determined. Types of electrodes are arranged at inner array in tables of orthogonal arrays so that we can estimate machining performances of each electrode. Coating wire shows better performances than brass wire in cutting speed but it produces poor surface roughness, and two wires shows similar performance in straightness

Influence of Electrical Conductivity of Dielectric on Machinability of W-EDM (방전액의 전도율이 와이어방전가공성에 미치는 영향)

  • Kim, Chang-Ho;Hur, Kwan-Do;Kwon, Taek-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2001.06c
    • /
    • pp.64-70
    • /
    • 2001
  • This work deals with the electrical conductivity of dielectric and cobalt percentage on output parameters such as metal removal rate and surface roughness value of sintered carbides cut by wire-electrical discharge machining (W-EDM). To obtain a precise workpiece with good quality, some extra repetitive finish cuts along the rough cutting contour are necessary. Experimental results show that increases of cobalt amount in carbides affects the metal removal rate and worsens the surface quality as a greater quantity of solidified metal deposits on the eroded surface. Lower electrical conductivity of the dielectric results in a higher metal removal rate as the gap between wire electrode and workpiece reduced. Especially, the surface characteristics of rough-cut workpiece and wire electrode were analyzed too. To obtain a good surface equality without cracks, 4 finish-cuts were necessary by reducing the electrical energy and the offset value.

  • PDF

Wire Feeding Speed Control for Improving Welding Performances in Inverter Arc Welding Machine

  • Gho, J.S.;Chae, Y.M.;Chae, J.W.;Mok, H.S.;Choe, G.H.;Shin, W.S.
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.464-469
    • /
    • 1998
  • In the conventional wire feeder drives of welding machine, one thyristor or MOSFET device was used for half-wave phase control circuit and direct EMF measurement was used for sensing the wire feed rate. But the method using one switching device has poor response for sudden disturbance and it has latent speed ripple. It can affect some welding performance such as spatter generation and irregular bead formming. Therefore, the welding performance using full-bridge PWM speed control scheme was compared with conventional driving scheme was compared with conventional driving scheme and experimented in this paper. The results of experiment confirm the posibility of welding performance improvement by proposed constant speed control scheme in wire feeding drive of welding machine.

  • PDF

Electrical sensing of SOI nano-wire BioFET by using back-gate bias (Back-gate bias를 이용한 SOI nano-wire BioFET의 electrical sensing)

  • Jung, Myung-Ho;Ahn, Chang-Geun;Cho, Won-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.354-355
    • /
    • 2008
  • The sensitivity and sensing margin of SOI(silicon on insulator) nano-wire BioFET(field effect transistor) were investigated by using back-gate bias. The channel conductance modulation was affected by doping concentration, channel length and channel width. In order to obtain high sensitivity and large sensing margin, low doping concentration, long channel and narrow width are required. We confirmed that the electrical sensing by back-gate bias is effective method for evaluation and optimization of bio-sensor.

  • PDF

A Study on Crane Wire Rope Flaws Signal Processing Using Discrete Wavelet Transform (Wavelet 변환을 이용한 크레인 와이어 로프 결함 신호처리에 관한 연구)

  • Min, Jeong-Tak;Sohn, Dong-Seop;Lee, Jin-Woo;Lee, Kwon-Soon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2002.11a
    • /
    • pp.155-159
    • /
    • 2002
  • Wire ropes are used in a myriad of various industrial applications such as elevator, mine hoist, construction machinery, lift, and suspension bridge. Especially, wire rope of crane is important component to container transfer. If it happens wire rope failures in operating, it may lead to safety accident, economic power loss by productivity decline, competitive power decline of container terminal and so on. To solve this problem, we developed wire rope fault detecting system as a portable instrument, and this system is consisted of 3 parts that fault detecting part using hall sensor, permanent magnets and analog unit, and digital signal processing part using data acquisition card, monitoring part using wavelet transform, denoising method. In this paper, a wire rope is scanned by this system after makes several broken parts on the surface of wire rope artificially. All detected signal has external noise or disturbance according to circumstances. So, we applied to discrete wavelet transform to extract a signal from noisy data that was used filter. In practical applications of denoising, it is shown that wavelet pursue it with little information loss and smooth signal display. It is verified that the detecting system by denoising has good efficiency for inspecting faults of wire ropes in service. As a result, by developing this system, container terminal could reduce expense because of extension of wire ropes exchange period and could competitive power. Also, this system is possible to apply in several fields like that elevator, lift and so on.

  • PDF