Performance Comparison of the Railway Traction IPM Motors between Concentrated Winding and Distributed Winding

  • Park, Chan-Bae;Lee, Byung-Song;Lee, Hyung-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.118-123
    • /
    • 2013
  • This paper presents performance comparison between concentrated winding and distributed winding of IPMSM (Interior Permanent Magnet Synchronous Motors) which is recently used for light-weight railway applications. Motors are designed on various schemes and analyzed by using FEM (Finite Element Method) instead of EMCNM (Equivalent Magnetic Circuit Network Method) in order to take into account saturation and non-linear magnetic property. The overall performance such as torque, torque ripple, losses, demagnetization, efficiency, power density and so on are investigated in detail at the rated and maximum operating speed. The results of the analysis found that both concentrated and distributed winding IPMSMs are promising candidates for high power railway traction motor.

교류 급전시스템 성능검증을 위한 시험방안에 관한 연구 (A Study on tests process for verification of AC Traction system performance)

  • 정호성;이기원;김주락;한문섭;김진희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2202-2203
    • /
    • 2011
  • AC substation of urban transit supplies a suitable AC power on electricity vehicles. AC substation is verified electrical safety of system through pre-operation inspection on electrical installations to be supplied power from KEPCO. However, because test items and method for AC traction system are unprepared on pre-operation inspection, the general safety and performance verification of AC traction system are very insufficient. Therefore this paper analyze the test examples such as factory equipment tests, factory combined tests and railway tests for the safety and performance verification of AC traction system and present a suitable test items and test standard in domestic.

  • PDF

철도차량 견인전동기의 상태진단 및 상시감시 기술 (Condition Diagnosis & On-line Monitoring Technology on the Traction Motor for Railway Rolling Stock)

  • 왕종배;변윤섭;백종현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 제2회 학술대회 논문집 일렉트렛트 및 응용기술전문연구회
    • /
    • pp.36-39
    • /
    • 2000
  • This paper presents the technology of condition diagnosis & life estimation on insulation system of the traction motor. In the non-destructive methods for diagnosis of coil insulation state, residual dielectric strength is estimated by the D-map which consist of the partial discharge quantity Q and average degradation degree $\Delta$. In the operating history of machine, the N-Y life estimation method is based on the stop-starting numbers and operating times with considering each degradation factor by the thermal, electrical and heat-cycle stress. With the on-line conditioning monitoring on the currents of traction motors, detecting the abnormal operating state due to bearing faults, stator or armature faults, eccentricity related faults and broken rotor bars can be performed.

  • PDF

전철 탑재용 DC 피뢰기의 설계 및 전계분포 특성 (Electric Field Analysis and Design of Direct current Arresters for electric Traction Vehicles)

  • 조한구;유대훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1442_1442
    • /
    • 2009
  • This paper describes electric field analysis and design of direct current arresters for electric traction vehicles. Generally, DC arresters are used to protect the electric traction to limit the overvoltage invading into its inner electrical circuits. We could proposed operating voltage(Uc), the rated voltage(Ur). Finally maxwell 2D simulator based on the boundary element method was also introduced in order to verify the reliability of the DC arresters.

  • PDF

Study on Motor Characteristics due to Deviation of the Wheel Diameters with Parallel Operation

  • Lee, Hyung-Woo
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.106-109
    • /
    • 2013
  • It is desirable and advantageous to feed parallel propulsion with induction motors by a single voltage source inverter. However, effects of deviation of the wheel diameters on motor current, rotor speed and torque should be also considered for parallel operation. In order to understand the behavior and characteristics, a simple simulation model is developed by using a commercial Matlab Simulink. From the results, it is clear to manage the diameter deviation of the wheels which are connected to traction motors.

전압원 인버터 파형에 따른 견인 전동기의 맥동 토오크 해석 (The Analysis of the torque ripple of Traction Motor in the VSI system)

  • 리기홍;윤신용;김용;백수현;강호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.145-147
    • /
    • 1996
  • Traction Motor is being transferred to the squirrel cage induction motor from D.C motor, by the improved power semiconductors like GTO, IGBT, etc. In the Induction Motor, inverter system must be used for delivering variable voltage variable frequency. But, by pulsating in the system the harmonics would be produced, and that cause the torque ripple and enfeeble the dynamic characteristics of the motor. So, to use the inverter system, we should take the torque ripple into consideration. To minimize the torque ripple in the VSI fed Traction Motor, the optimal pulsating was presented in this paper. By using the SPWM(Sinusoidal Pulse Width Modulation) method, feeding the appropriate pulse, we can minimize the torque ripple and improve the transient response.

  • PDF

과도서지를 이용한 가속열화 시험법에 따른 견인전동기 고정자 코일의 전기적 특성 변화 (Properties of Electrical Performance on Stator Coil of Traction Motor by Accelerated lest using Transient Surge)

  • 박현준;장동욱;이길헌;최종선;김저우
    • 한국전기전자재료학회논문지
    • /
    • 제16권9호
    • /
    • pp.783-789
    • /
    • 2003
  • The winding problems of traction motor are the major determinant of motor's life. The root cause of winding failure is gradual deterioration of the insulation due to thermal, electrical, mechanical and environmental stresses. The aging of the insulation reduces the electrical and mechanical strength of the insulation. At same point, a voltage surge or mechanical shock from a traction motor start will fracture or break down the insulation. To achieve the expected life usually requires extensive laboratory evaluation of the insulation systems and the use of accelerated aging tests. There are several nondestructive test available for checking, the condition of motor insulation, the probable extent of aging, and the rate of which aging is taking place. So the insulation characteristics of stator coil were each analyzed by measurement of dielectric loss(tan$\sigma$), capacitance and partial discharge. The method of diagnosis is able to analyze the insulation condition and evaluate the life of the traction motor.

Determination Method of Centerpost Distance of Interior Permanent Magnet Synchronous Motor for Electric Vehicle Traction Motor considering Mechanical Safety

  • Kim, Sung-Jin;Kim, Yong-Jae;Jung, Sang-Yong;Suzuki, Kenji
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제2권1호
    • /
    • pp.51-56
    • /
    • 2013
  • With the active development of hybrid electric vehicle (HEV), the application of interior permanent magnet synchronous motor (IPMSM) has been expanded. As wide driving region of IPMSM for electric vehicle (EV) traction motor is required, many studies are conducted to improve characteristics of a motor in both low and high-speed driving regions. A motor in high-speed driving region generates (produces) large stress to the rotor. Thus, the rotor needs to be designed considering the mechanical safety. Therefore, in this paper, we conducted stress analysis and electromagnetic analysis to determine the centerpost's distance which is considered important during the design of IPMSM for EV traction motor in order to secure mechanical safety and satisfy specifications of output requirement.

철도 차량용 고출력 고효율 선형 추진시스템 설계 (A Design of Linear Motor with High Power Density and High Efficiency for Railway and Magnetic Levitation System)

  • 강도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.393-396
    • /
    • 2001
  • According to the development of power electronic element(GTO, IGBT) and material for electrical machines(permanent magnet, super conductor), the technology for electrical machines is nowaday rapidly developing. Here with, a novel electrical machine, based on the new conception of transverse flux configuration leads to a considerable Increase in power density and enables simultaneously high efficiency. The transverse flux machine with PM excitation will be applied to gearless direct drives for railway traction system and magnetic levitation system. The designed and measured performance of transverse machine for railway traction system and magnetic levitation system revealed a great potential of system improvements to reduce linear motor mass and increase efficiency.

  • PDF

$2{\times}25 kV$급전 방식에서의 공동 접지망 적용에 따른 귀선 전류의 영향 (Effects of the Common Earth Network on the Traction Return Current in $2{\times}25 kV$ Power Supply System)

  • 김용규;류창근
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권9호
    • /
    • pp.509-514
    • /
    • 2002
  • The aim of this research is to find out how the common earth network affects the level of the traction return current in the $2{\times}25 kV$ Power Supply System. The traction return current plays a significant role in the operation of the facilities near the rails. It is shown that the common earth network in the $2{\times}25 kV$ power supply system not only minimizes the level of the traction return current, but also increases the safety of the working crew on the railways. In order to determine the relationship between common earth network and the traction return current, we investigated the earth system of the Gyongbu High Speed Line that is constructed following the SNCF regulations. We carried out the field test in the Osong station. The results of the test show that the common earth network minimizes the effect of the traction return current. We also find that the simulated results are very similar to the test results. We concluded that the results of the test can be applied for the rest of the Gyongbu High Speed Line under construction.