• 제목/요약/키워드: Electrical stimulus

검색결과 199건 처리시간 0.025초

전기 자극 강도에 따른 소장 내부에서의 수축력 관계 (Relationship between electrical stimulus strength and contraction force from the inside of small intestine)

  • 우상효;김태완;이정현;박희준;문연관;원철호;이승하;박일용;조진호
    • 센서학회지
    • /
    • 제17권1호
    • /
    • pp.1-8
    • /
    • 2008
  • Recently, capsule endoscope was developed to observe small intestine in human body. However, the capsule does not have any locomotive ability, which reduces the benefit of the capsule endoscope. Many researches have done to give locomotion to the capsule, still it consumes too much power to generate the motion by small battery. One of the moving method is electrical stimulus that consumes less power than many methods. The electrical stimulus method causes contraction in the small intestine, and it moves the capsule. Some of papers showed it is possible to guide the capsule by electrical stimulus, however the relationship between electrical stimulus at the mucous and contraction force in the small intestine is not reported, yet. In this paper, the mucous in the small intestine was stimulated, and measured the contraction force in the small intestine is shown. The result shows, the relationship between electrical stimulus parameters (voltage, duration) and contraction force. Also, equation between electrical stimulus parameters and contraction force is roughly induced.

하반신마비 환자에서 보행기능의 복원을 위한 전기자극법의 개발 (Development of Electrical Stimulator for Restoration of Locomotion in Paraplegic Patients)

  • 박병림;김민선
    • 대한의용생체공학회:의공학회지
    • /
    • 제15권4호
    • /
    • pp.429-438
    • /
    • 1994
  • An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate eleclromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocnemius m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher'stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical slimulator restored partially gait function in paraplegic patients.

  • PDF

An Improved FES System for Control of Paralyzed Upper Extremity

  • 류영재
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1993년도 춘계학술대회
    • /
    • pp.120-122
    • /
    • 1993
  • This paper describes an improved FES system to restore paralyzed extremities in spinal cord injury patients. For composing stimulus pattern which is suitable for each muscle, electrical stimulus pattern creating system is also developed by using IBM-PC. In the improved portable FES system using V40 microprocessor, muscle fatigue can be decreased by selecting the stimulus frequency which is proper to the response characteristics of each muscle. Driving softwares for the portable FES system and the stimulus pattern creating system are programmed with assembler and C language. A multichnnel portable FES system is designed to minimize the sire and weight using a D/A converter and 32 channel multiplexer.

  • PDF

자극원에 따른 보라성게(Heliocodaris crassispina)의 이동패턴 분석 (The Behavioral Response of Purple Sea Urchins Heliocodaris crassispina to Food and an Electrical Stimulus)

  • 오태건;이정관;황학진;편용범;한인우;오우석;박근창;이경훈
    • 한국수산과학회지
    • /
    • 제52권5호
    • /
    • pp.524-533
    • /
    • 2019
  • Sea urchins are hugely destructive of marine forest ecosystems. This study aimed to determine the behavioral response of purple sea Urchins Heliocodaris crassispina to food and an electrical stimulus and to investigate the attraction radius of these stimuli, with an eye to the development of technology for controlling sea urchin numbers. Ten purple sea urchins, housed in circular acrylic tank, were tested against various attractant stimuli. In addition, an experiment was conducted with 200 purple sea urchins in a large water tank to observe movement patterns and the attractiveness of various stimuli. In the smaller experiment, eight out of 10 sea urchins were attracted to food, and these attractive effects were maintained in all except one of the affected urchins. However, the attractant effects of the electrical stimulus were maintained in only three sea urchins. The results of the larger experiment indicated that differences in the attractant power of food and an electrical stimulus were 54%-78%, and approximately 5-15% of sea urchins were attracted by the electrical stimulus.

The Impact of Functional Electrical Stimulus and Proprioceptive Neuromuscular Facilitation to Scapula Adductor on Upper Limb Functions and Gait of the Patients with Stroke

  • Moon, Sang-Hyun;Hong, Wan-Sung;Kim, Sang-Soo;An, Ho-Jung;Song, Young-Hwa;Kim, Yong-Kwon;Choi, Jung-Hyun;Kim, Bo-Kyoung;Kim, Sung-Ho;Choi, Wan-Suk;Min, Kyoung-Ok
    • 국제물리치료학회지
    • /
    • 제1권2호
    • /
    • pp.143-148
    • /
    • 2010
  • The present study examined the effects of functional electrical stimulus(group 1), proprioceptive neuromuscular facilitation(group 2) and combined training of functional electrical stimulus and proprioceptive neuromuscular facilitation(group 3) with scapula adductor muscles on scapula movement, upper limb function and gait in fifteen subjects stroke patients. The training was thirty minutes a day, five times a week for six weeks, obtained result as follow, upper limb function was significant difference in the group 2(p<.05) but no significant difference in other groups. The change of weight bearing were significant difference in all the groups(p<.05), and increase of gait velocity were significant difference in all the group(p<.05). In conclusion, when applied with functional electrical stimulus, proprioceptive neuromuscular facilitation and combined training to the scapular adductor muscles, it was oberved in the course of the experiment that proprioceptive neuromuscular facilitation was the most effective treatment among the three methods applied to the scapula adductors.

  • PDF

아조벤젠 유기박막의 광자격 특성에 관한 연구 (A Study on the Light Stimulus Properties by Azobenzene Organic Thin Films)

  • 조수영;김성진;송진원;이순형;정헌상;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.41-44
    • /
    • 1999
  • Displacement current was generated in the pressure stimulus and light stimulus. Solution of azobenzene molecules (8A5H) have to character trans-to-cis. Pressure stimulus generate in the pressure and current. light stimulus generate in the displasement current. The Maxwell displacement current measuring technique has been applied for the investigation of azobenzene organic thin films under alternating photoirradiation with ultraviolet(360nm) and visible (450nm) light. The displacement current was generated due to the trans-to-cis photoisomerization by irradiation with ultraviolet light(λ$_1$=360 nm) Whereas the displacement current was generated in the opposite direction due to the cis-to-trans photoisomerization by irradiation with visible light(λ$_2$=450nm). As result, To show twice reaction certainly phase transition in pressure. A first range generated from 24$\AA$$^2$ to 29$\AA$$^2$and second range generated from 20$\AA$$^2$to 24$\AA$$^2$. Also, cetainfy stimulus apper low pressure and high pressure in photoirradiation. To see different every moment phase transition.

  • PDF

전기자극을 이용한 점자인식장치의 최적조건 (Optimal Conditions of Braille Recognition System Using Electrical Stimulus)

  • 이승직;신재호;야구성일
    • 대한의용생체공학회:의공학회지
    • /
    • 제17권3호
    • /
    • pp.373-378
    • /
    • 1996
  • In this paper, we calculated chronaxy value in order to determine the optimal conditions and stimulus pulse of information transmission. We also developed an electrical equivalent circuit of the hand including the contact part, which consists of two resistors (a contact resistor and finger resistor) and a capacitor. The minimum recoulition voltage was measured by using electrical stimulus. We found that the ranges of the above two resistances and the capacitance are 30-130k$\Omega$, 20-60k$\Omega$ and 10-30nF respectively. We found that the minimum recoulition voltage was the lowest at 100-300Hz and 10% of the duty ratio.

  • PDF

DLPC 인지질 단분자막의 변위전류 특성 (Displacement Current Characteristics of DLPC Lipid Monolayer)

  • 최용성;송진원;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.10-11
    • /
    • 2006
  • The azobenzene dendrimer is one of the dendrimeric macromolecules that include the azo-group exhibiting a photochromic character. Due to the presence of the charge transfer element of the azo-group and its rod-shaped structure, these compounds are expected to have potential interest in electronics and photoelectronics, especially in nonlinear optics. In the present paper, we give pressure stimulation to organic thin films and detect the induced displacement current. Functional photoisometrization organic molecular the photo-stimulus to organic monomolecular L films and LB films of dendrimer and SASH were performed. The SASH organic monolayer in case of pressure stimulus occurred that positive course but in case of the photo-stimulus compared positive and negative. It is assumed that generation forms of displacement current were measured when photo-stimulus for impression.

  • PDF

나노구조 단분자막의 전기적 특성 (Electrical Characteristics of Nano-Structural Monolayer)

  • 최용성;조장훈;송진원;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.166-167
    • /
    • 2006
  • Dendrimers represent a new class of synthetic macromolecules characterized by a regularly branched treelike structure. Multiple branching yields a large number of chain ends that distinguish dendrimers from conventional star-like polymers and microgels. The azobenzene dendrimer is one of the dendrimeric macromolecules that include the azo-group exhibiting a photochromic character. Due to the presence of the charge transfer element of the azo-group and its rod-shaped structure, these compounds are expected to have potential interest in electronics and photoelectronics, especially in nonlinear optics. In the present paper, we give pressure stimulation to organic thin films and detect the induced displacement current. Functional photoisometrization organic molecular the photo-stimulus to organic monomolecular L-films and LB films of dendrimer and 8A5H were performed. The 8A5H organic monolayer in case of pressure stimulus occurred that positive course but in case of the photo-stimulus compared positive and negative. It is assumed that generation forms of displacement current were measured when photo-stimulus for Impression.

  • PDF

Neurogram을 이용한 인공와우 자극기법 평가 연구 (Evaluation of Stimulus Strategy for Cochlear Implant Using Neurogram)

  • 양혜진;우지환
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.47-54
    • /
    • 2013
  • Electrical stimulation is delivered to auditory nerve (AN) through the electrodes in cochlear implant system. Neurogram is a spectrogram that includes information of neural response to electrical stimulation. We hypothesized that the similarity between a neurogram and an input-sound spectrogram could show how well a cochlear implant system works. In this study, we evaluated electrical stimulus configuration of CIS strategy using the computational model. The computational model includes stochastic property and anatomical features of cat auditory nerve fiber. To evaluate similarity between a neurogram and an input-sound spectrogram, we calculated Structural Similarity Index (SSIM). The results show that the dynamic range and the stimulation rate per channel influenced SSIM. Finally, we suggested the optimal configuration within the given stimulus CIS. We expect that the results and the evaluating procedure could be employed to improve the performance of a cochlear implant system.