Optimal Conditions of Braille Recognition System Using Electrical Stimulus

전기자극을 이용한 점자인식장치의 최적조건

  • Published : 1996.09.01

Abstract

In this paper, we calculated chronaxy value in order to determine the optimal conditions and stimulus pulse of information transmission. We also developed an electrical equivalent circuit of the hand including the contact part, which consists of two resistors (a contact resistor and finger resistor) and a capacitor. The minimum recoulition voltage was measured by using electrical stimulus. We found that the ranges of the above two resistances and the capacitance are 30-130k$\Omega$, 20-60k$\Omega$ and 10-30nF respectively. We found that the minimum recoulition voltage was the lowest at 100-300Hz and 10% of the duty ratio.

Keywords

References

  1. IEICE Trans. on fundamentals v.E76-A no.7 The sensitivity finger due to electrical stimulus pulse for a tactile vision substitution system Seungjik Lee;Jaeho Shin;Seiichi Noguchi
  2. IEEE Trans. on Fundamentals v.E77-A A study on the tactile recognition of finger using electrical stimulus Seungjik Lee;Jaeho Shin;Hyunpil Joo;Takashi Uchiyama;Seiichi Noguchi
  3. 第18回感覺代行シンポジウム發表論文集 PCを利用した盲聾者のコミュニケションエイド 伊藤春樹;小田浩一
  4. 電子情報通信學會論文誌 v.J73-A no.3 盲人用地圖制作および音聲案內システムの開發 牧野秀夫
  5. 電子情報通信學會論文誌 v.J72-D-II no.9 盲人用圖面認識支援システム 河井良浩;大西昇;彬江昇
  6. 日本音響學會誌 v.43 no.5 感覺補助代行の基本問題 吉本千禎
  7. 電子情報通信學會論文誌 v.J74-A no.10 點字讀取り中の指先擊動解析 大竹勉
  8. 전자공학회논문지 v.29-B no.6 일측마비환자의 전기자극에 의한 보행기능의 회복 朴炳林;金民先;金相洙;鄭東明;洪勝弘
  9. MBE84-107 多チャンネル機能的電氣刺激(FES)システム 飯島克己;二見豪弘;星宮望;半田康延
  10. 日本電子情報通信學會 秋季大會 電氣刺激を加えた時の指の等價回路について 李丞植;申宰浩;朱鉉弼;野口誠一
  11. 醫用電子工學 池田謙一
  12. 生體工學 星宮望
  13. 醫用計測技術 吉田徹
  14. 生體用テルメ-タ·電氣刺激裝置 綿貫喆;內山明彦;池山硏二