• Title/Summary/Keyword: Electrical stimulation system

Search Result 255, Processing Time 0.029 seconds

Electrical Stimulation System Design for Pharyngeal Dysfunction of Stroke Patients (뇌졸중 환자의 인두기능 회복을 위한 전기자극기 설계)

  • 김성민;배하석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1232-1235
    • /
    • 2004
  • The purpose of this study is to design electrical stimulation system for pharyngeal dysfunction(dysphagia) in stroke patients. Pharyngeal muscle group activity is important, because contracting muscles provide the driving force at the initiation of the swallow and generate the pressure gradients necessary for bolus movement into the esophagus. Although we have many treatment methods for dysphagia, electrical stimulation system will be useful for stroke patients having dysphagia. Electrical stimulation can be divided into the body stimulation and electrodes. The body stimulation is divided again into frequency counter, time control and current measurement part. These parts are to control the current intensity, frequency and stimulating time. And they can be variable according to the patient's clinical assessment. The electrode plays a role to deliver the current from the system to the muscle. Also the position of the electrode can be variable according to the treatment method. We performed the clinical experiment with the stroke patient who has swallowing disorder. The videofluoroscopy was used for the observation. From the result of clinical experiment based on electrical stimulation, we expected that the dysfunction(in pharynx) level of the patient can be improved. However we could not have enough effectiveness of the treatment because of the number of patients, patient's adaptation and treatment period. We will design the optimized electrical stimulation system based on enough clinical experiment in the future.

  • PDF

Electrical Stimulation System Design for Pharyngeal Dysfunction of Stroke Patients (뇌졸중 환자의 인두기능 회복을 위한 전기자극기 설계)

  • Yoo Ji Hye;Bae Ha Suk;Choi Byoung Cheol;Kim Sung Min
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.7 s.172
    • /
    • pp.185-190
    • /
    • 2005
  • The purpose of this study is to design electrical stimulation system fur stroke patients with pharyngeal dysfunction(dysphagia). Dysphagia is that the food has trouble in passing to the mouth from the stomach. Although we have many treatment methods for dysphagia, electrical stimulation system will be useful for stroke patients having dysphagia. Electrical stimulation system can be divided into body and electrodes. The body stimulation is composed to frequency counter, time control and current measurement part. These parts are to control the frequency, stimulating time and current intensity And they can be variable according to the patient's clinical assessment. The electrode plays a role to deliver the current from the system to the muscle. Also the position of the electrode can be variable according to the treatment method. We performed the clinical experiment with stroke patients who had swallowing disorder. The videofluoroscopy was used fur the observation. From the result of clinical experiment based on electrical stimulation, we expected that the dysfunction(in pharynx) level of the patient could be improved. However we could not have enough effectiveness of the treatment because of the number of patients, patient's adaptation and treatment period. We will design the optimized electrical stimulation system based on enough clinical experiment in the future.

Changes in Sympathetic Nervous System Responses of Healthy Adult Women with Changes in the Stimulus Intensity of High Frequency Transcutaneous Electrical Nerve Stimulation (고빈도 경피신경전기자극의 자극강도에 따른 정상 성인여성 교감신경성 반응의 변화)

  • Choi, Yoo-Rim;Lee, Jeong-Woo
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.61-66
    • /
    • 2010
  • Purpose: The purpose of this study was to investigate the change in sympathetic nervous system responses of healthy adult women with changes in stimulus intensity of high frequency transcutaneous electrical nerve stimulation. Methods: Twenty-four healthy subjects (women) received high frequency electrical stimulation of the forearm. The subjects were randomly assigned to one of two groups; a low intensity stimulation group (n=12) and a high intensity stimulation group (n=12). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was 20 minutes. Measured items included skin conductance, pulse rate, skin temperature, and respiration rate. Each was measured at 4 times. Results: Skin conductance and skin temperature showed significant group by time interactions, though there were no significant group and time effects. There were no significant differences according to time, group effect, and a group by time interaction in pulse and respiration rates. Conclusion: High frequency and high intensity electrical stimulation may be helpful for the improvement of sudomotor function through the activation of the sympathetic nervous system. Also, high frequency and low intensity electrical stimulation may be helpful for the reduction of sudomotor function via inhibition of the sympathetic nervous system.

A portable multichannel FES system for control of paralyzed extremities (마비된 말단근육의 제어를 위한 휴대용 다중 채널의 기능적 전기자극(FES) 장치)

  • 류영재;박봉기;김영민;임영철;김하경
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10a
    • /
    • pp.90-94
    • /
    • 1992
  • A portable multichannel functional electrical stimulation(FES) system for the fine control of the paralyzed extremities in spinal cord injury patients is described. This system is composed of a stimulation data creating system, a serial communication device, a 16-bit microprocessor, D/A converter of 32 channels and a display device. Stimulation patterns are created from analytical results of integrated EMGs during motion in normal subjects and are stored in the stimulation data creating system as data files. And then the stimulation patterns are sent to the memory in the portable multichannel FES system through serial communication interfacing device. Sophisticated fine control of paralyzed extrimities was realized by transmitting multichannel stimulation patterns to percutaneous intramuscular electrodes, which stimulate the motor function of paralyzed muscle simultaneously. Advantages of this system are as follws: 1) It is possible to modify stimulation patterns in accordance with the patient's situation. 2) This system is small and light.

  • PDF

Effect of Electrical Stimulation Level on Quantitative Sensory Test Induced Erythema by UV Radiation (전기자극수준이 자외선에 의한 홍반의 정량적 감각검사에 미치는 효과)

  • Kim, Su-Hyon;Kim, Hyun-Jin
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.2
    • /
    • pp.1-6
    • /
    • 2012
  • Purpose : This study is to investigate the modulatory effects to the ultraviolet induced erythema of pain processing system. Methods : Thirty six healthy volunteers were divided into none treatment group (n=6), indomethacine group (n=6), subsensory level electrical stimulation group (n=6), sensory level electrical stimulation group (n=6), motor level electrical stimulation group (n=6), noxious level electrical stimulation group (n=6). Subjects were induced erythema for three times minimal erythema dose (MED) at upper arm of dermatome C6 level. Each experimental group had mechanical pain threshold (MPT), electrical pain threshold (EPT), thermal pain threshold (TPT). Results : This study revealed that we observed that pain thresholds were significantly correlated with each other in pain processing system. The effect of electrical stimulation levels evaluates were shown to be significant differences pain control effect in electrical stimulation group (sensory, motor level electrical stimulation groups) more than indomethacine group, subsensory level and control group. Conclusion : In this study, it was found that the effect of ultraviolet induced erythema of pain control by modulatory electrical stimulation.

The Development of Neuromuscular Electrical Stimulation Medical Devices for The Treatment of Non-implantable Urinary Incontinence (비이식형 요실금 치료용 신경근 전기자극 의료기기 개발)

  • Lee, Jae-Yong;Lee, Chang-Doo;Kwon, Ki-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.175-181
    • /
    • 2015
  • In this paper, the neuromuscular electrical stimulation medical devices for non-implantable incontinence treatment other than vaginal insertion type was developed and commercialized. The structure of medical devices for electrical stimulation based on the anatomy of the pelvic floor muscle designed. Then, the optimum parameters that may be effective in pelvic floor muscle electrical stimulation was set. The circuit system based on the optimum parameters were designed and manufactured. The frequency of the pulse voltage for electrical stimulation is 75[Hz], the pulse width is 300[${\mu}s$], the development of medical devices was to have seven program functions to the various treatments. The circuit system of medical devices was composed of microcontroller, comparator and converter. The performance of the developed circuit system in KTC(Korea Testing Certification) were carried out medical equipment inspection test. Test results, test specifications were satisfied with the medical device, the performance was verified to be commercialized as a medical device. The development of medical devices were validated risk assessment and product performance through a software validation. Commercialization of medical equipment was acquired to enable the certification standards of the international standard IEC 60601-1.

The Effect of Electrical Stimulation Applied in Dominant Forearm on Autonomic Nervous System Response of Both Hands (우세측 전완에 적용한 전기자극이 양쪽 손 자율신경계 반응에 미치는 효과)

  • Lee, Dong-Geol;Seo, Sam-Ki;Lee, Jeong-Woo
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.7-10
    • /
    • 2009
  • Purpose : The purpose of this study was to investigate the effect of electrical stimulation applied in dominant forearm on autonomic nervous system response of both hands. Methods : Fourteen healthy subjects (women) received low frequency-high intensity electrical stimulation to one forearm. The subjects assigned to two groups; a ipsilateral stimulation group (n=7) and a contralateral stimulation group (n=7). The electrode attachment was arranged on the forearm of the dominant arm and the electricity stimulus time was set as 15 minutes. Measuring items were the skin conduction velocity, the blood flow, and the pulse rate, which were measured total 3 times (pre, post, and post 10 min.). Results : The skin conduction velocity showed a significant difference according to the change of the time in both hands, but there was no significant difference according to time in the blood flow, and the change of the pulse frequency regardless of stimulus side. Conclusion : These results demonstrate that the low frequency-high intensity electrical stimulation applied dominant forearm can increase selectively only with the skin conduction velocity, which may be helpful for the activation of the sudomotor function of both hands by the activation of sympathetic nerve.

Influence of Acupuncture Stimulation on Electrical Resistance under Adiaphoresis Induced by Regional Anaesthesia (국소마취에 의한 발한 억제 상태에서 침자극이 인체 전기 저항에 미치는 영향)

  • Park, Kyung-Mo
    • Journal of Acupuncture Research
    • /
    • v.17 no.4
    • /
    • pp.130-138
    • /
    • 2000
  • Objectives : When sweating factor is excluded, to know the influence of acupuncture stimulation on electrical resistance. Methods : Regional anaesthesia(Lidocane 2%, 1ml, Subcutaneous injection) is applied to measured regions, 4cm round area including left Neiguan P6. So we can make adiaphoresis. Before and after acupucnture stimulation to Laogong P8, we measured the electrical resistance of anesthetized left Neiguan P6, anesthetized non-acupoint, normal left Ximen P4, and normal right Neiguan P6. For measurment, we use the 1.2V, DC system that has 100$k{\Omega}$ internal resistance Results : Under the adiaphoresis, Acupuncture stimulation makes the significant decrease of electrical resistance. In normal regions, so does it. Conclusions : When the acupuncture stimulation is applied to human boby, the decrease of electrical resistance is due not only to sweat secretion but also to other internal resistance.

  • PDF

Evaluation of Stimulus Strategy for Cochlear Implant Using Neurogram (Neurogram을 이용한 인공와우 자극기법 평가 연구)

  • Yang, Hyejin;Woo, Jihwan
    • Journal of Biomedical Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.47-54
    • /
    • 2013
  • Electrical stimulation is delivered to auditory nerve (AN) through the electrodes in cochlear implant system. Neurogram is a spectrogram that includes information of neural response to electrical stimulation. We hypothesized that the similarity between a neurogram and an input-sound spectrogram could show how well a cochlear implant system works. In this study, we evaluated electrical stimulus configuration of CIS strategy using the computational model. The computational model includes stochastic property and anatomical features of cat auditory nerve fiber. To evaluate similarity between a neurogram and an input-sound spectrogram, we calculated Structural Similarity Index (SSIM). The results show that the dynamic range and the stimulation rate per channel influenced SSIM. Finally, we suggested the optimal configuration within the given stimulus CIS. We expect that the results and the evaluating procedure could be employed to improve the performance of a cochlear implant system.

New Methods of Vagus Nerve Stimulation : Therapeutic Effects of Non-Invasive Vagus Nerve Stimulation by TENS Application (미주신경 자극을 위한 새로운 방법 : 비침습적 TENS 적용에 대한 미주신경 자극의 치료적 효과)

  • Kwon, Haeyeon;Moon, Hyunju
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.4 no.4
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the therapeutic effect of non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation application on the autonomic nervous system of human body. Methods: Participants were seventeen healthy adults. Standard deviation of all normal N-N intervals(SDNN), root mean square of successive differences(RMSSD), low frequency(LF), high frequency(HF) were compared in pre and post Mean values after intervention. Data were analyzed in Wilcoxon's signed-ranks test. Results: The results of this study is that sistolic blood pressure and pulse rate decreased mean value after non-invasive vagus nerve stimulation by transcutaneous electrical nerve stimulation. High frequency, low frequency, SDNN, RMSSD increased mean value in heart rate variability after intervention. But that is not significant except for SDNN. Conclusion: Non-invasive vagus stimulation by transcutaneous electrical nerve stimulation effect on parasympathetic nerve stimulation, and then it might be effective method for autonomic nerve balance control.