• 제목/요약/키워드: Electrical stability

검색결과 4,442건 처리시간 0.027초

An analysis of robust stability for time delay systems based on lyapunov type operator equation

  • E. Shimemura;K. Uchida;A. Kojima
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1989년도 한국자동제어학술회의논문집; Seoul, Korea; 27-28 Oct. 1989
    • /
    • pp.901-906
    • /
    • 1989
  • A robust stability problem for time delay systems is discussed by using a property of Lyapunov type operator equation. We propose a method to check the robust stability against the parameter perturbations occurring in both lumped parameter part and distributed delay element.

  • PDF

온라인 전력계통 안정도 진단을 위한 선로 선정 방안 (Identification of Correlative Transmission Lines for On-Line Stability Diagnosis)

  • 조윤성;장길수;권세혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.3-6
    • /
    • 2001
  • Power system stability is correlated with system structure, disturbances and operating conditions. and power flows in transmission lines are closely related with those conditions. This paper discusses a methodology to identify crucial transmission lines for stability diagnosis with respect to transient stability and small-signal stability. On-line monitoring of the selected lines enables to predict system stability in real-time. Also, a Procedure to make a priority list of monitored transmission lines using contingency analysis. The procedure is applied to the PSS/E test system. and it shows capabilities of the proposed method.

  • PDF

ZPCCY계 세라믹 바리스터의 소결시간에 따른 전기적 특성 및 안정성 (The Electrical Properties and Stability of ZPCCY-Based Ceramic Varistors with Sintering Timpertature)

  • 정영철;류정선;남춘우
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집 Vol.14 No.1
    • /
    • pp.472-475
    • /
    • 2001
  • The electrical properties and stability of ZPCCY-based varistors composing of $ZnO-Pr_{6}O_{11}-CoO-Cr_{2}O_{3}-Y_{2}O_{3}$ ceramics were investigated with sintering time. As sintering time is increased, the nonlinear exponent decreased in the range of 51.19~26.70. Among varistors having above 30 in nonlinear exponent, for the varistor sintered for 1h, the nonlinearity was superior to the stability comparatively and, in the case of 2h, the stability was superior to the nonlinearity relatively. Consequently, it is estimated that the varistors sintered for 1~2h will be applied to various fields by trade-off between nonlinearity and stability.

  • PDF

A Novel Line Stability Index for Voltage Stability Analysis and Contingency Ranking in Power System Using Fuzzy Based Load Flow

  • Kanimozhi, R.;Selvi, K.
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권4호
    • /
    • pp.694-703
    • /
    • 2013
  • In electric power system, the line stability indices adopted in most of the instances laid stress on variation of reactive power than real power variation of the transmission line. In this paper, a proposal is made with the formulation of a New Voltage Stability Index (NVSI) which originates from the equation of a two bus network, neglecting the resistance of transmission line, resulting in appreciable variations in both real and reactive loading. The efficacy of the index and fuzzy based load flow are validated with IEEE 30 bus and Tamil Nadu Electricity Board (TNEB) 69 bus system, a practical system in India. The results could prove that the identification of weak bus and critical line in both systems is effectively done. The weak area of the practical system and the contingency ranking with overloading either line or generator outages are found by conducting contingency analysis using NVSI.

Stability Analysis of Grid-Connected Inverters with an LCL Filter Considering Grid Impedance

  • Li, Xiao-Qiang;Wu, Xiao-Jie;Geng, Yi-Wen;Zhang, Qi
    • Journal of Power Electronics
    • /
    • 제13권5호
    • /
    • pp.896-908
    • /
    • 2013
  • Under high grid impedance conditions, it is difficult to guarantee the stability of grid-connected inverters with an LCL filter designed based on ideal grid conditions. In this paper, the theoretical basis for output impedance calculation is introduced. Based on the small-signal model, the d-d channel closed-loop output impedance models adopting the converter-side current control method and the grid-side current control method are derived, respectively. Specifically, this paper shows how to simplify the stability analysis which is usually complemented based on the generalized Nyquist stability criterion (GNC). The stability of each current-controlled grid-connected system is analyzed via the proposed simplified method. Moreover, the influence of the LCL parameters on the stability margin of grid-connected inverter controlled with converter-side current is studied. It is shown that the stability of grid-connected systems is fully determined by the d-d channel output admittance of the grid-connected inverter and the inductive component of the grid impedance. Experimental results validate the proposed theoretical stability analysis.

댐핑 영향을 반영하는 Lyapunov 함수 그룹의 유도 및 응용 (Derivation of a Group of Lyapunov Functions reflecting Damping Effects and its Application)

  • 문영현;최병곤;노태훈;이태식;이윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.195-198
    • /
    • 1995
  • Most of the theorems of nonlinear stability is based on the Lyapunov stability theory. The Lyapunov function method is the most well-known and provides precise and rigorous theoretical backgrounds. However, tile conventional approach to direct stability analysis has been performed without taking account of damping effects. For accurate stability analysis of nonlinear systems, it is required to consider the damping effects. This paper presents a new method to derive a group of Lyapunov functions to reflect the damping effects by considering the integral relationships of the system governing equations. This method tan be utilized as a powerful tool to determine the region of attraction.

  • PDF

손실재분배와 정적전압의존형 부하모델을 고려한 전압안정도 해석 (Voltage Stability Analysis considering Static Voltage Dependent Load Model and Loss Redistribution)

  • 김근성;채명석;신중린;임한석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 추계학술대회 논문집 학회본부
    • /
    • pp.215-217
    • /
    • 1997
  • In many conventional analysis of voltage stability the effect of load characteristics is ignored. But in the real system the load is composed of various components. Therefore if the load composition could be modeled then it will plays an important role in the analysis of static voltage stability. And also, if the system loss generally imposed to slack bus in the conventional load flow calculation is redistributed to each generator the accuracy of static voltage stability analysis can be improved. This paper presents the effect of load composition in the analysis of system stability as well the loss redistribution algorithm. And this paper will compare the result of conventional method with that of the proposed method.

  • PDF

Novel Techniques for Real Time Computing Critical Clearing Time SIME-B and CCS-B

  • Dinh, Hung Nguyen;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.197-205
    • /
    • 2013
  • Real time transient stability assessment mainly depends on real-time prediction. Unfortunately, conventional techniques based on offline analysis are too slow and unreliable in complex power systems. Hence, fast and reliable stability prediction methods and simple stability criterions must be developed for real time purposes. In this paper, two new methods for real time determining critical clearing time based on clustering identification are proposed. This article is covering three main sections: (i) clustering generators and recognizing critical group; (ii) replacing the multi-machine system by a two-machine dynamic equivalent and eventually, to a one-machine-infinite-bus system; (iii) presenting a new method to predict post-fault trajectory and two simple algorithms for calculating critical clearing time, respectively established upon two different transient stability criterions. The performance is expected to figure out critical clearing time within 100ms-150ms and with an acceptable accuracy.

Voltage Stability Prediction on Power System Network via Enhanced Hybrid Particle Swarm Artificial Neural Network

  • Lim, Zi-Jie;Mustafa, Mohd Wazir;Jamian, Jasrul Jamani
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.877-887
    • /
    • 2015
  • Rapid development of cities with constant increasing load and deregulation in electricity market had forced the transmission lines to operate near their threshold capacity and can easily lead to voltage instability and caused system breakdown. To prevent such catastrophe from happening, accurate readings of voltage stability condition is required so that preventive equipment and operators can execute security procedures to restore system condition to normal. This paper introduced Enhanced Hybrid Particle Swarm Optimization algorithm to estimate the voltage stability condition which utilized Fast Voltage Stability Index (FVSI) to indicate how far or close is the power system network to the collapse point when the reactive load in the system increases because reactive load gives the highest impact to the stability of the system as it varies. Particle Swarm Optimization (PSO) had been combined with the ANN to form the Enhanced Hybrid PSO-ANN (EHPSO-ANN) algorithm that worked accurately as a prediction algorithm. The proposed algorithm reduced serious local minima convergence of ANN but also maintaining the fast convergence speed of PSO. The results show that the hybrid algorithm has greater prediction accuracy than those comparing algorithms. High generalization ability was found in the proposed algorithm.

A New Method for Monitoring Local Voltage Stability using the Saddle Node Bifurcation Set in Two Dimensional Power Parameter Space

  • Nguyen, Van Thang;Nguyen, Minh Y.;Yoon, Yong Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권2호
    • /
    • pp.206-214
    • /
    • 2013
  • This paper proposes a new method for monitoring local voltage stability using the saddle node bifurcation set or loadability boundary in two dimensional power parameter space. The method includes three main steps. First step is to determine the critical buses and the second step is building the static voltage stability boundary or the saddle node bifurcation set. Final step is monitoring the voltage stability through the distance from current operating point to the boundary. Critical buses are defined through the right eigenvector by direct method. The boundary of the static voltage stability region is a quadratic curve that can be obtained by the proposed method that is combining a variation of standard direct method and Thevenin equivalent model of electric power system. And finally the distance is computed through the Euclid norm of normal vector of the boundary at the closest saddle node bifurcation point. The advantage of the proposed method is that it gets the advantages of both methods, the accuracy of the direct method and simple of Thevenin Equivalent model. Thus, the proposed method holds some promises in terms of performing the real-time voltage stability monitoring of power system. Test results of New England 39 bus system are presented to show the effectiveness of the proposed method.