• Title/Summary/Keyword: Electrical safety standards

Search Result 204, Processing Time 0.024 seconds

Solvent Vapor Annealing Effects in Contact Resistances of Zone-cast Benzothienobenzothiophene (C8-BTBT) Transistors

  • Kim, Chaewon;Jo, Anjae;Kim, Heeju;Kim, Miso;Lee, Jaegab;Lee, Mi Jung
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.4
    • /
    • pp.411-416
    • /
    • 2016
  • Benzothienobenzothiophene ($C_8-BTBT$) is a soluble organic small molecule material with high crystallinity resulting from its strong self-organizing properties. In addition, the high mobility and easy fabrication of $C_8-BTBT$ make it very attractive in terms of organic thin-film transistors. In this work, we made $C_8-BTBT$ thin films by using the zone-casting method; we also used an organic solvent to treat the devices with solvent vapor annealing to improve the electrical properties. As a result, we confirmed improved mobility, threshold voltage, and subthreshold swing after solvent vapor annealing. To prove the effect of solvent vapor annealing, we used the simultaneous extraction model to extract the contact resistance from the current-voltage curve. We confirmed that the electrical properties improved with decreasing contact resistance.

A Comparative Study on the Luminous Flux by Degree of Non-directional LED Lamps and Incandescent lamp (확산형 LED램프와 백열램프의 각도별 광속에 관한 비교연구)

  • Park, Chang-Yong;Seo, Jeong-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.32-39
    • /
    • 2014
  • In general, non-directional LED lamps including high transmittance cover are more advantageous than directional LED lamps, which are efficient enough to improve luminous efficacy and obtain certification, allowing wide manufacture, sale, and distribution. Although KS C 7651(Self-ballasted LED lamps-Safety and performance requirements) was revised in July 2013, however, many companies are having a lot of difficulties in keeping the certification and product development for the lack of the photometric analysis for non-directional LED lamps. In this paper, through the measurement of the angular distribution of luminous flux of incandescent lamp and non-directional LED lamps, we examined the reasonability of non-directional LED lamps' standards as suggested in KS C 7651. According to the results, even if non-directional LED lamps satisfy KS C 7651, when compared to an incandescent lamp, they showed less diffusive than the incandescent lamp and the distribution of the luminous flux depending on the angle fluctuated greatly even among LED lamps. Judging by the result, the current standard of the non-directional LED lamps, KS C 7651, has been comprehended that the angular distribution of the luminous flux needs to be presented after being much more thoroughly standardized.

A Study on the Development of Test Facility for Safety System Software V/V in Nuclear Power Plant (원자력발전소 안전계통 소프트웨어의 확인/검증을 위한 시험장치 개발에 관한 연구)

  • Lee, Sun-Sung;Suh, Young;Moon, Chae-Joo
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.96-102
    • /
    • 1998
  • The use of computers as part of nuclear safety systems elicits additional requirements-software verification and validation (v/v), hardware qualification-not specifically addressed in general industry fields. The computer used in nuclear power plants is a system that includes computer hardware, software, firmware, and interfaces. To develop the computer systems graded with nuclear safety class, the developing environments have to be required in advance and the developed software have to be verified and validated in accordance with nuclear code and standards. With this requirements, the test facility for Inadequate Core Cooling Monitoring System (ICCMS) as one of safety systems in the nuclear power plants was developed. The test facility consists of three(3) parts such as Input/Output (I/O) simulator, Plant Data Acqusition System (PDAS) cabinets and supervisory computer. The performance of the system was validated by manual test procedure.

  • PDF

A Study on the Improvement of the Safety and Safe Living Standards of Apartment Houses through AHP Analysis (AHP 분석을 통한 공동주택 안전 및 안심생활 수준 향상에 관한 연구)

  • Ji, Yung il;Shin, Seung Ha;Choi, Byong Jeong
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.2
    • /
    • pp.289-305
    • /
    • 2021
  • Purpose: The purpose of this study is to check the importance of higher level, sub higher level and lower alternative factor and the factor for relieved life and also check the comprehensive priority in executed "Safety and relieved life level improvement of apartment house residents by AHP analysis". Method: The safety management evaluation elements and alternatives have been arranged as hierarchical structure based on the preceding studies and the advice of experts for the maintenance and system of apartment house in this study. Study model is used for the survey of pair wise comparison composition targeting experts and AHP analysis method is used for alternative plan ranking, etc. Result: The response result of survey secured the consistency and it is confirmed that safety inspection for apartment house electricity facility is most important for higher level, safety inspection, detailed inspection and diagnosis evaluation are most important for sub higher level and plumbing equipments is most important for alternatives based on the analysis result of relative weight comparison for sub higher level and alternatives for final goal attainment of the study. Conclusion: Plumbing equipments, crime prevention safety and electrical safety are shown as top priority alternatives when observe it with expert manager's point of view for apartment house. It shows that securing the importance of living safety accident and deciding the level of relieved life can be improved are the alternatives of pre-prevention and management strengthening.

A Case Study of Risk Assessments and Safety Measures in a PCB Manufacturing Process (인쇄회로기판 제조 공정에서 위험성평가와 안전조치 적용 사례 연구)

  • Lee, Young Man;Lee, Inseok
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.4
    • /
    • pp.120-128
    • /
    • 2022
  • Printed circuit boards (PCBs) are a basic component in the electronics industry and are widely used in nearly all electronic products, such as mobile phones, tablet computers, and digital cameras, as well as in electric equipment. PCB manufacturing involves the use of many chemicals and chemical processes and therefore has more risks than other manufacturing sectors. This study aims to identify the causes of possible accidents during PCB manufacturing through risk assessment, develop and implement safety measures, and evaluate the effectiveness of these measures. Note that the safety measures developed to mitigate the risks of a certain process were also implemented for other similar processes. The risk assessments conducted over seven years, from 2015 to 2021, at a PCB manufacturing company identified 361 hazardous processes. Between 2016 and 2019, 41-56 hazardous processes were identified per year; such processes decreased to fewer than 20 per year after 2020. Application of the risk assessment results to the improvement of the hazardous processes with the similar characteristics seems to be effective in decreasing the risks. Equipment-related factors such as lack of appropriate maintenance, low work standards, and defective protection devices were responsible for 59.8% of all possible accidents. Because PCB manufacturing involves many chemicals, skin contact with hazardous substances, electric shock, fire, and explosion were the most common types of possible accidents (81.7%). In total, 505 safety measures were implemented, including 157 related to purchase and improvement of equipment and devices for safety (31.1%), 147 related to the installation/modification of fire prevention facilities (29.1%), and 69 related to the use of standard electrical appliances (13.7%). Risk assessment conducted after implementing the safety measures showed that these measures significantly decreased risk; 247 processes (68.4%) had a risk level of 3, corresponding to "very low," and 114 processes (31.6%) showed a risk level of 4, corresponding to "low." In particular, risk assessment of 104 processes with risk scores of 12 and 10 other processes with risk score of 16 showed that the risk decreased to 4 after implementing the safety measures. Thus, implementing these measures in similar manufacturing sectors that involve chemical processes can mitigate risk.

erratum : A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (erratum : 전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.44 no.1
    • /
    • pp.128-128
    • /
    • 2023
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

Fatigue wind load spectrum construction based on integration of turbulent wind model and measured data for long-span metal roof

  • Liman Yang;Cong Ye;Xu Yang;Xueyao Yang;Jian-ge Kou
    • Wind and Structures
    • /
    • v.36 no.2
    • /
    • pp.121-131
    • /
    • 2023
  • Aiming at the problem that fatigue characteristics of metal roof rely on local physical tests and lacks the cyclic load sequence matching with regional climate, this paper proposed a method of constructing the fatigue load spectrum based on integration of wind load model, measured data of long-span metal roof and climate statistical data. According to the turbulence characteristics of wind, the wind load model is established from the aspects of turbulence intensity, power spectral density and wind pressure coefficient. Considering the influence of roof configuration on wind pressure distribution, the parameters are modified through fusing the measured data with least squares method to approximate the actual wind pressure load of the roof system. Furthermore, with regards to the wind climate characteristics of building location, Weibull model is adopted to analyze the regional meteorological data to obtain the probability density distribution of wind velocity used for calculating wind load, so as to establish the cyclic wind load sequence with the attributes of regional climate and building configuration. Finally, taking a workshop's metal roof as an example, the wind load spectrum is constructed according to this method, and the fatigue simulation and residual life prediction are implemented based on the experimental data. The forecasting result is lightly higher than the design standards, consistent with general principles of its conservative safety design scale, which shows that the presented method is validated for the fatigue characteristics study and health assessment of metal roof.

Data Acquisition System Design of I&C System in Nuclear Power Plant (원자력 발전소 계측제어시스템의 정보취득장치 설계)

  • 조정환;이동희
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.102-108
    • /
    • 2003
  • This paper presents a new Data acquisition system that can improve a accuracy and response characteristics by designing a SDAS(Signal Datat Acquisition System). I&C(Instrumentation and Control) system, which it applied for Nuclear Power Plant, affects for safety either directly or indirectly. It should be assessed by the equipment qualification procedure to confirm the functionality during design life before it apply on the nuclear power plant depending on safety classification. This paper proposes data acquisition system that required as an essential measurement equipment in the method and procedure of equipment qualification following of standards and codes of IEEE and Nuclear Regulatory Guide. It provides comparable and experimental studies have been carried out. The presented results from the above investigation show considerably improved accuracy performance in the data acquisition system. This circuit will be able to be used in high performance I&C system.

FMECA Procedure for Failure Analysis of Train High-Speed Circuit Breaker (전동차 고속차단기 고장 분석을 위한 FMECA 기법)

  • Kim, Sung-Ryeol;Moon, Yong-Sun;Choi, Kyu-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3370-3377
    • /
    • 2015
  • FMECA(Failure Mode, Effects and Criticality Analysis) techniques to make quantitative evaluation of failure effects severity and criticality have been applied to systematic failure analysis for reliability improvement of train which should provide regular service and secure high level of safety as a mass transportation system. These FMECA techniques do not fully reflect the inherent train operation and maintenance circumstances because they are based on the FMECA standards devised for other industries such as automobile industry and FMECA standard dedicated to train industry has not been established yet. This paper analyzes FMECA standards for various industries, and suggests a FMECA technique dedicated to train industry which makes failure effect analysis and criticality analysis step by step and makes criticality analysis placing emphasis on the severity of the failure effect. The proposed technique is applied to FMECA of high-speed current breaker which is a core safety device of train using field failure data for 15 years of train maintenance. The FMECA results show that breakage of arc chute has the highest risk with 3rd severity class and 5th criticality class among all the components of high-speed circuit breaker. Damage and poor contact of electronic valve, and cylinder breakage with 3rd severity class and 4th criticality class are followed by. These results can be applied to improvement of design and maintenance process for high-speed circuit breaker of train.

Analysis of Battery Performance Test for DC Power System in Nuclear Power Plant (원자력발전소 직류전원계통용 축전지 성능시험 분석)

  • Kim, Daesik;Cha, Hanju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.2
    • /
    • pp.61-68
    • /
    • 2014
  • Function of battery bank stores energy for DC load in general, and DC power system of the nuclear power plant is used to supply DC loads for safety- featured instrumentation and control such as inverter, class 1E power system control and indication, and station annunciation. Class 1E DC power system must provide a power for the design basis accident conditions, and adequate capacity must be available during loss of AC power and subsequent safe shutdown of the plant. In present, batteries of Class 1E DC power system of the nuclear power plant uses lead-acid batteries. Class 1E batteries of nuclear power plants in Korea are summarized in terms of specification, such as capacity, discharge rate, bank configuration and discharge end voltage, etc. This paper summarizes standards of determining battery size for the nuclear power plant, and analyzes duty cycle for the class 1E DC power system of nuclear power plant. Then, battery cell size is calculated as 2613Ah according to the standard. In addition, this paper analyzes performance test results during past 13 years and shows performance degradation in the battery bank. Performance tests in 2001 and 2005 represent that entire battery cells do not reach the discharge-end voltage. Howeyer, the discharge-end voltage is reached in 14.7% of channel A (17 EA), 13.8% of channel B (16 EA), 5.2% of channel C (6 EA) and 16.4% of channel D (19 EA) at 2011 performance test. Based on the performance test results analysis and size calculation, battery capacity and degradation by age in Korearn nuclear power plant is discussed and would be used for new design.