• 제목/요약/키워드: Electrical safety standards

Search Result 204, Processing Time 0.035 seconds

A review on the stray current countermeasures of DC electric railways(1) Europe and Australia (직류전기철도의 누설전류 방지대책에 대한 고찰(1) 유럽과 호주)

  • Ha, Yoon-Cheol;Bae, Jeong-Hyo;Ha, Tae-Hyun;Lee, Hyun-Goo;Kim, Dae-Kyeong
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1075-1076
    • /
    • 2006
  • The wide spread of DC electric railway systems such as urban rapid transits including heavy rail and light rail transits has significant ramification as the stray currents from return conductor rails can cause the electrochemical interference, that is, the electrolytic corrosion of both rails and outside underground metallic infrastructures. The immature understanding of either the railway authority who is responsible for establishing the necessary provisions at the design stage or the affected parties makes it difficult to prepare the optimum range of solutions for the long-pending interference problem. In advanced countries, however, numerous assessment studies have been carried out on the stray current interference, by which protective standards and regulations are provided under the collaboration and agreement of the related parties. In this paper, we introduce a european standard from IEC, namely, "IEC 62128-2:2003 railway applications-fixed installations -part 2: protective provisions against the effects of stray currents caused by d.c. traction systems" and a "Code of Practice" produced by Victorian electrolysis committee (VEC) based on "Electricity Safety Act 1998" and "Electricity safety (stray current corrosion) regulations 1999" of Victoria state, Australia.

  • PDF

Signalling System Standardization for Linear Induction Motor Type Light Rail Transit (선형유도모터형식 경전철 신호제어시스템 표준사양 연구)

  • Cho, Bong-Kwan;Hwang, Hyeon-Chyeol;Cho, Hong-Shik;Hong, Jai-Sung;Ryu, Sang-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1183-1184
    • /
    • 2007
  • Light Rail Transit (LRT) is optimized vehicle system for complex urban circumstance. LRT systems have many merits such as improved accuracy and safety. There are many LRT systems such as monorail, tram, automated guideway transit, linear induction motor propulsion and so on. These systems have been operated in Japan and other advanced countries. In Korea, local government has many projects to apply the advanced LRT system. But there are no standards regulation, performance test regulation and construction regulation for monorail system, linear induction motor system and tram in Korea. We expect that standardization brings economical construction and safety. The linear induction motor system has been usually applied to subway in Japan and ART(Advanced Rapid Transit) in Canada. In Korea, the linear induction motor system has been adopted for Yong-In LRT and currently under construction. This paper presents signalling system and TCMS(train control and monitoring system) of linear induction motor system.

  • PDF

A preliminary evaluation of the implementation of a radiation protection program for the lens of the eye in Korean nuclear power plants

  • Kong, Tae Young;Kim, Si Young;Cho, Moonhyung;Jung, Yoonhee;Son, Jung Kwon;Jang, Han;Kim, Hee Geun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.3035-3043
    • /
    • 2021
  • Epidemiological research has revealed that radiation exposure can cause cataracts. The Korean nuclear regulatory body has proposed the reduction of the occupational dose limit for the lens of the eye from 150 mSv/y to 100 mSv/5y, with an additional limitation of not exceeding 50 mSv/y for a specific year, taking into account the recommendations of the International Commission on Radiological Protection, and the International Atomic Energy Agency. This means that radiation workers should receive the same level of radiation safety for the lens of the eye as for whole-body protection. Korean nuclear power plants (NPPs) are conducting research to establish the radiation protection program for the lens of the eye. In terms of the preliminary results of the implementation of the radiation protection program for the lens of the eye dedicated to Korean NPPs, this review article summarizes the current state of understanding of the regulations, technical guidance, eye lens dosimeters, and radiation field conditions resulting in lens dose.

Random Vibration Analysis of Portable Power Supply Container for Radar With U.S. Military Standards (미 군사규격을 적용한 레이더 전력공급용 이동식 컨테이너의 Random Vibration 해석)

  • Do, Jae-Seok;Hur, Jang-Wook
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.71-77
    • /
    • 2022
  • In times of war or emergencies, weapon systems, such as radars, must receive stable power. This can be achieved using improved onboard portable power systems made of steel containers. However, a breakdown can occur in the event of random vibration during transportation via a vehicle or train. Electrical-power shortages or restrictions pose a significant threat to security. In this study, Composite Wheeled Vehicle(CWV) data and rail cargo data with Acceleration Spectral Density(ASD), specified in MIL-STD-810H METHOD 514.8, were interpreted as input data of the three-axis random vibration method using ANSYS 19.2. Modal analysis was performed up to 500 Hz, and deformations in modes 1 to 117 were calculated to utilize all ASD data. The maximum equivalent stress in the three-axis direction was obtained using a random vibration analysis. Similarly, the margin of safety was calculated using the derived equivalent stress and material properties. Overall, the analysis verified that the portable container designed for the power supply system satisfied the required vibration demands.

Consideration of a LED Luminaire Standard for Naval Vessels (함정용 LED 조명기구의 표준화 방안)

  • Kim, Il-Kwon;Cho, Hyang-Eun;Kil, Gyung-Suk;Kwon, Hyuk-Sang;Cho, Heung-Gi
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.06a
    • /
    • pp.182-182
    • /
    • 2011
  • This paper dealt with a design guide of LED luminaire standard for naval vessels. Several standards such as Korean Industrial Standard (KS), Korea Defence Standard (KDS) and US Military Standard (MIL) were compared in terms of safety and performance of lighting fixtures. The electrical and optical characteristics of the FL fixtures were experimentally analyzed to acquire design rules for LED luminaires. Based on the study results, we proposed the concept of a LED luminaire standard.

  • PDF

Analysis of International Trend on the Standard for Power System Connection of V2G System (V2G 시스템의 계통연계에 대한 국제 표준 동향 분석)

  • Lee, Soon-Jeong;Kim, Jun-Hyeok;Kim, Chul-Hwan;Kim, Gi-Hyun;Shin, Seong-Su
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.1641-1642
    • /
    • 2015
  • Recently, the interest about Vehicle-to-Grid(V2G) system which can use the electric vehicles as generation sources or storage devices has rapidly increased. However, this technology does not use widely yet, and there is no clear standard or regulation for it. If electric vehicles are connected to the power system indiscreetly, it can cause problem to personnel safety and adverse effect on the power system. Therefore, it is important to analyze the related standards. In this paper, we introduce some international standard related with V2G system.

  • PDF

Analysis of Electro-magnetic Interference Noise for Eco-friendly Vehicle (친환경 자동차의 전자파 방사 노이즈 특성 분석)

  • Kim, Hae-Sung;Yong, Boo-Joong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.76-81
    • /
    • 2011
  • Fossil fuel, the energy source of internal combustion engine automobiles, is limited in resource and has caused environmental issues for decades. Accordingly, automobile manufacturers from many countries around the world are developing or producing eco-friendly vehicles that utilize alternative sources of energy. These vehicles are equipped with many electronic and electrical components which operate on high voltage and/or large current that were not used in conventional combustion engine automobiles. In this paper, in order to analyze the electro-magnetic interference noise, electric vehicles and fuel cell electric vehicles are tested under the guidelines of KMVSS (Korean Motor Vehicle Safety Standards) as well as under test modes that are not stipulated under the guidelines.

Soil Breakdown Test using Fixture (Fixture를 이용한 토양 절연파괴 실험)

  • Lee, H.G.;Ha, T.H.;Jung, D.H.;Ha, Y.C.;Kim, D.K.;Bae, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.384-385
    • /
    • 2007
  • The fault current through the earth originated from a power line ground fault might cause arcing through the soil to an adjacent pipeline, which might bring about not only a catastrophic accident such as gas explosion and oil leakage but also a hazard to the safety of workers responsible for the maintenance and repair of the pipeline. In this paper we experimented on the soil breakdown test using the fixture and outlined the standards for the separation distance of a buried pipeline adjacent to the power line tower.

  • PDF

Study on Electrical Impedance Matching for Broadband Ultrasonic Transducer (광대역 초음파 변환기를 위한 전기 임피던스 정합 연구)

  • Kim, Geonwoo;Kim, Ki-Bok;Baek, Kwang Sae
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.37-43
    • /
    • 2017
  • Ultrasonic transducers with high resolution and resonant frequency are required to detect small defects (less than hundreds of ${\mu}m$) by ultrasonic testing. The resonance frequency and resolution of an ultrasonic transducer are closely related to the thickness of piezo-electric materials, backing materials, and the electric impedance matching technique. Among these factors, electrical impedance matching plays an important role because it can reduce the loss and reflection of ultrasonic energy differences in electrical impedance between an ultrasonic transducer and an ultrasonic defects detecting system. An LC matching circuit is the most frequently used electric matching method. It is necessary for the electrical impedance of an ultrasonic transducer to correspond to approximately $50{\Omega}$ to compensate the difference in electrical impedance between both connections. In this study, a 15 MHz immersion ultrasonic transducer was fabricated and an LC electrical impedance circuit was applied to that for having broad-band frequency characteristic.

Research of the Turnout Maintenance Training System using Mixed Reality (혼합현실을 이용한 분기기 유지보수 교육시스템 연구)

  • Song, Yong-Soo;Kim, Yong-Kyu;Shin, Duck-Ho;Chang, Sang-Hoon
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1511-1516
    • /
    • 2011
  • The maintenance of the turnout is composed of signal field and track field on business, the electrical and mechanical field on system. adjustment and maintenance carry forward through coordination with these fields. In the case of turnout equipment used in a first phase of Seoul-Busan high-speed train, it is treated by classifying as mechanical adjustments and electrical adjustments. Mechanical adjustment is conducted with focus on fine adjustment to meet maintenance standards limits(1mm or less) about interval of basic rail and tongue rail about each part of track transition equipment. This refers to mechanical adjustments performed mainly with physical changes and movement characteristics between basic rail and tongue rail by considering the overall environment surrounding track side of section installed track transition equipment. However, these series of maintenance are conducted in state that high-speed train is not in the process from 1 am to 4 am at night, but common workers for maintenance are not familiar with the operation and checking about various situation, and the workers are even insufficient. Maintenance training using mixed reality is conducted in the place of business, we tried to overcome several problems of safety and time reduction through this training.

  • PDF