• Title/Summary/Keyword: Electrical safety standards

Search Result 204, Processing Time 0.021 seconds

Evaluation of the Effect of High Temperature on the Interface Characteristics between Solid Oxide Fuel Cell and Ag Paste (고온열처리가 고체산화물연료전지의 전극과 Ag 페이스트의 계면에 미치는 특성 평가)

  • Jeon, Sang Koo;Nahm, Seung Hoon;Kwon, Oh Heon
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.1
    • /
    • pp.21-27
    • /
    • 2015
  • In this study, interfacial characteristics between SOFC and Ag paste as current collector was estimated in the high temperature environment. The Ag paste was used to connect the unit cell of SOFC strongly with interconnector and provide the electrical conductivity between them. To confirm electrical conductivity, Ag paste was treated in the furnace at $800^{\circ}C$ for 48 hours. The sheet resistance of Ag paste was measured to compare the resistance values before and after the heat treatment. Also, the four-point bending test was performed to measure the interfacial adhesion. The unit cell of SOFC and $SiO_2$ wafer were diced and then attached by Ag paste. The $SiO_2$ wafer had the center notch to initiate a crack from the tip of the notch. The modified stereomicroscope combined with the CCD camera and system for measuring the length was used to observe the fracture behavior. To compare the characteristics before heat treatment and after heat treatment, the specimen was exposed in the furnace at $800^{\circ}C$ for 48 hours and then the interfacial adhesion was evaluated. Finally, the interfacial adhesion energy quantitatively increases $1.78{\pm}0.07J/m^2$ to $4.9{\pm}0.87J/m^2$ between the cathode and Ag paste and also increase $2.9{\pm}0.47J/m^2$ to $5.12{\pm}1.01J/m^2$ between the anode and Ag paste through the high temperature. Therefore, it is expected that Ag paste as current collector was appropriate for improving the structural stability in the stacked SOFC system if the electrical conductivity was more increased.

A Study on The Software Coding Standard for Safety of Railway Embedded System (철도내장형제어기의 안전확보를 위한 소프트웨어 코딩규약 확보방안)

  • Shin, Kyung-Ho;Joung, Eui-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.193-195
    • /
    • 2008
  • Safety is important factor in railway system. Now most of the electric and electronic system which is applied in railway system is the embedded system which software is used. The constitution rate of software which is involved in railway system is gradually increasing. Most of the software which is used in railway system is implemented by the software developer. Thus the implemented code has different features according to the developer and this may cause the bad effect on the software's maintenance. International standard IEC 62279 requires an adoption the coding standard to developing the railway software. And it is plan to recommend complying with the coding standard in safety criteria for railway software which is noticed as the regulation of the Korean railway safety law. In this paper, we review the requirement of coding standards which is present in the software criteria for railway software and international standard. Also it investigates the coding standard which is in other safety related industry and presents the effective way to apply the software coding standard to domestic railway industry.

  • PDF

Development for Worker Safety Management System on the EOS Blockchain (EOS 블록체인 기반의 작업자 안전관리 시스템 개발)

  • Jo, Yeon-Jeong;Eom, Hyun-Min;Sim, Chae-Lin;Koo, Hyeong-Seo;Lee, Myung-Joon
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.9 no.10
    • /
    • pp.797-808
    • /
    • 2019
  • In a closed workplace, the management of the workplace is important because the environmental data at the workplace has a great influence on the safety of workers. Today's industrial sites are transformed into data-based factories that collect and analyze data through sensors in those sites, requiring a management system to ensure safety. In general, a safety management system stores and manages data on a central server associated with a database. Since such management system introduces high possibility of forgery and loss of data, workers often suspect the reliability of the information on the management system. In this paper, we present a worker safety management system based on the EOS blockchain which is considered as third-generation blockchain technology. The developed system consists of a set of smart contracts on the EOS blockchain and 3 decentralized applications associated with the blockchain. According to the roles of users, the worker and manager applications respectively perform the process of initiating or terminating tasks as blockchain transactions. The entire transaction history is distributed and stored in all nodes participating in the blockchain network, so forgery and loss of data is practically impossible. The system administrator application assigns the account rights of workers and managers appropriate for performing the functions, and specifies the safety standards of IoT data for ensuring workplace safety. The IoT data received from sensor platforms in workplaces and the information on initiation, termination or approval of tasks assigned to workers, are explicitly stored and managed in the EOS smart contracts.

Electrical Characteristics Analysis of LED Lamps using Internal Converter for Road and Street Lighting (컨버터 내장형 LED 가로등 및 보안등의 전기적 특성 분석)

  • Kim, Hyang-Kon;Gil, Hyoung-Jun;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.238-244
    • /
    • 2010
  • In this paper, we studied electrical characteristics of internal converter type of LED lamps for road and street lighting. We surveyed electro-technical regulations and KS(Korean industrial standards) about LED luminairs. Waveforms of voltage and current, thermal distributions, insulation resistances between live parts and exposed conductive parts, and flame test of cover of LED lamps were experimented and analyzed. In regulations, insulation resistance between live conductors and exposed conductive parts should be greater than $0.2M{\Omega}$ in case nominal voltage of wiring is 220V. In KS codes, the value of insulation resistance should be greater than $2M{\Omega}$ while applying DC 500V or DC 100V. In the result of this study, waveforms of primary voltage and current were distorted. There was difference in waveforms of secondary voltage and current according to composition of converter. Mostly, insulation resistances were measured high more than regulation and code value but some measured points were measured badly($0.0M{\Omega}$). Cover of LED lamps was ignited easily. We expect that the results of this study would be helpful for revision of regulations and national codes for the electrical safety of LED road and street lighting.

Process Development of a Standard Operating Procedure (SOP) for the Manufacturing of Standardized Distribution Boards (규격화된 분전반 제작을 위한 표준작업절차(SOP)의 공정 개발)

  • Ko, Wan-Su;Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.21-27
    • /
    • 2018
  • The purpose of this study is to develop a SOP (Standard Operating Procedure) for a distribution board that can monitor the leakage current of a load distribution line in real time. The developed distribution board was fabricated by applying IEC 61439-1. It consists of the distribution board and an alarm device. The work process for making the distribution board was compliant with the KEMC (Korea Electrical Manufacturers Cooperative) regulations. And the AC distribution board range is 1,000 V. In addition, the voltage in DC is less than 1500 V. The distribution board receives a 3-phases and 4-wires power supply system and can supply power to the load of a maximum of 32 single or three phase distribution circuits. Also, leakage current measured on the power distribution board was used by sensors installed. The SOP of the developed distribution board consists of the installation standards for the short circuit alarm device and sensor, the surge protection device, switches and indication lamps, and other devices. The operation procedure was prepared so that each manufacturing step of the distribution board must be confirmed by the persons in charge of preparation, production, quality control and approval before moving forward to the next step.

Study of Standardization and Test Certification for Wearable Smart Devices (웨어러블 스마트기기의 표준화 및 시험인증 연구)

  • Han, Tae-Su;Kim, Deok-kee;Kwon, Oh-Young;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.11-18
    • /
    • 2016
  • Today, wearable technology products are used in a wide range of consumer, healthcare, bio-medical, and industrial applications. The market for wearable technology products is expected to increase dramatically over the next several years. In addition, concerns for safety, performance and reliability of wearable products keep increasing and will be essential for widespread acceptance in the marketplace. Wearable smart devices, which are generally in contact with the human body and skin, are exposed to the risk of the electric shock, burn, and explosion. Therefore, the standardization of wearable devices in terms of human safety and reliability should be very important. Furthermore, the development of test method and test certification of the wearable products will be one of the key technology for mass production. Such standardization and certification will help consumers to choose the safest and best quality wearable devices and allow manufacturers to prove the safety and quality of their products, thereby helping them to gain a competitive technology. This paper discusses the current status of the wearable smart devices as well as the standardization and test certification applicable to wearable technology products.

Analysis of revised regulatory guidance on electromagnetic interference qualification for nuclear safety

  • In Beom Ahn;Jaeyul Choo ;Jae Yoon Park ;Hyunchul Ku ;Kyeong-Sik Min
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.870-875
    • /
    • 2023
  • In this paper, we analyzed the revised guidance on electromagnetic (EM) interference qualification of Regulatory Guide 1.180 (Revision 2), which is published by the U.S. Nuclear Regulatory Commission for electromagnetic compatibility qualification for nuclear safety, by comparing it with that of the previous version. We confirmed that the test methods and the acceptance criteria of both CE101 and CE102 tests for conductive emission and RE102 test for radiating emission are changed in the recently revised Regulatory Guide 1.180 (Revision 2). Furthermore, we found that the revised Regulatory Guide 1.180 provides flexibility in the use of alternative methods for EM interference (EMI) qualification, in that a mix of the various base-standards is technically allowed. In addition, the primary revision of the updated Regulatory. Guide 1.180 is that MIL-STD-461G is to be adopted as the latest base-standard, instead of MIL-STD-461E. To evaluate the influence on EMI qualification for nuclear safety due to the endorsement of MIL-STD-461G, we thoroughly analyzed the modifications in the acceptance criteria and test methods for EMI qualification, and then validated the analyzed effect on the EMI qualification, which is caused by the revision of MIL-STD-461, by performing electromagnetic simulation for equipment under RE102 test.

A Study on Developing Safety and Performance Assessment Guideline for Electronic Warm-Acupuncture Apparatus (전기식 온침기에 대한 안전성 및 성능평가 가이드라인 개발 연구)

  • Hansol Jang;U-Ryeong Chung;Jeong-Hyun Moon;Seong-Kyeong Choi;Won-Suk Sung;Min-Seop Hwang;Seung-Deok Lee;Kyung-Ho Kim;Jong-Hwa Yoon;Eun-Jung Kim
    • The Journal of Korean Medicine
    • /
    • v.43 no.3
    • /
    • pp.150-163
    • /
    • 2022
  • Objectives: This research aimed to develop a guideline for evaluating safety and performance of electronic warm-acupuncture apparatus. With the development of medical devices like electronic warm-acupuncture apparatus with improved performance, convenience and safety measures compared to traditional warm-acupuncture needling, safety and performance guideline is a necessity. Methods: By referring to existing standards and guidelines of other electronic devices for Korean medicine with heating function, guideline for safety and performance assessment of electronic warm-acupuncture apparatus was drafted Results: The guideline, presents explanation for adequate temperature and settings of the apparatus, and safety measurements providing against thermal runaway situations along with guidelines for the manual. Guideline for detailed test method for the performance of the apparatus such as accuracy of temperature increase and the timer, and safety unit was also provided. The test items and suggested test methods for the requirements of biological, electrical and electromagnetic safety were referred to Korean approval documents of ministry of Food and Drug Safety. Conclusion: We proposed the relevant items to verify performance and safety of warm-acupuncture apparatus to assure patient safety and improve the quality of currently developing devices for application in clinical field.

An Experimental Study on Operation Setting Optimization of Circuit Breaker for Improving Safety on DC Railroad Feeder System (직류철도 급전계통의 안전성 향상을 위한 차단기 동작 최적 설정의 실험적 고찰)

  • Lee, Jae-Bong;Jung, No-Geon;Kim, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.3
    • /
    • pp.526-531
    • /
    • 2016
  • This paper presents an experimental study on the optimal settings for the selected DC fault relay (50F) to improve the operating performance for the high-speed circuit breaker on DC feeding system which ensure safety within rolling stock maintenance depot. In this study, current supplied to overhead contact wire was calculated on 1 ms interval to analyze the correction values of DC fault selective relay for the operation of current supply cutout. Particularly, standards for the accurate detection of accidents between an electric railway vehicle and the electric power facilities are shown by investigating the optimal correction values for detection of fault current, and the results indicated that it takes about 213 ms for the DC fault selective relay(50F) to fully open. In the future, the correction values of DC fault selective relay suggested in this paper will be used as the reference values of protective relay for the safe operation of DC electric railroad system such as urban railway.

Amendment of the Inspection Standard for Diagnostic Radiation Equipment Applying IEC 60601-1-3: Medical Electrical Equipment - Part 1-3: General Requirements for Basic Safety and Essential Performance - Collateral Standard: Radiation Protection in Diagnostic X-ray Equipment (KS C IEC60601-1-3: 의료용 전기기기-제1-3부: 기본 안전 및 필수 성능에 관한 일반 요구사항-보조표준: 진단용 X선 장치의 방사선 방어를 적용한 진단용 방사선 발생장치의 검사기준 개선안)

  • Park, Hye-Min;Kim, Jung-Min;Kim, Jung-Su;Kim, Seong-Ok;Choi, Young-Min
    • Journal of radiological science and technology
    • /
    • v.41 no.5
    • /
    • pp.493-504
    • /
    • 2018
  • The diagnostic radiation equipment is managed in accordance with the "Rules for Safety Management of Diagnostic Radiation Equipment" enacted in 1995. The equipments should be inspected before use and every three years after use in accordance with the [Appendix 1] of the same rule. The inspection standard has been maintained without particular revision since enacted. But, over the past two decades new types of equipments have been manufactured and used. So, it is necessary to revise [Appendix 1] by making inspection items and inspection standards. In this study, we revised the classification system of equipments and reviewed international standards of IEC 60601 series, IEC 61223 series and AAPM TG 18 On-line Report No.03. And identified the problem of current inspection standards. Through this, we revised, deleted and added the inspection items and inspection standard of each equipment to meet the domestic circumstances. As a result of the study, we reorganized the classification system of equipment which are current classified as 5 classes into 22 classes as X-ray system etc. (7 classes), CT system etc. (5 classes) and Dental X-ray system etc. (10 classes). And then, we developed 70 inspection items for 6 types of equipments according to the reorganized classification system of equipments. The inspection items and inspection standards derived from this study have been proposed to the KCDC and will be applied to the revision of the Rule's [Appendix 1]. Therefore, we expect to be used as reference materials for domestic medical center, inspection institutions, and equipment manufacturing import companies.