• Title/Summary/Keyword: Electrical safety standards

Search Result 204, Processing Time 0.037 seconds

A Study on the Optical Characteristics of LED Lamp as Alternative Type of FPL Lamp (FPL형광램프 대체형 LED램프의 조도특성에 관한 연구)

  • Ko, Jae-jun;Kim, Chung-hyeok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.10
    • /
    • pp.1-6
    • /
    • 2015
  • As lamps using LEDs are developed actively, also there have been large request for LED lamps that can replace traditional lamps like fluorescent lamps and metal halide lamps. But so far there are no proper standards that manufacturer can use and test their lamps. As a result of this, manufacturers are not only unable to develop LED lamps but also sell it even though they have technology. In this study, It is proposed that proper test method by investigating compatibility between all-type control gear and LED lamps by analyzing control gear for fluorescent lamp such as magnetic or electronic ballast that is currently used in the market.

A Study on the Health Evaluation in Spot Welded Zone by Using Optical Pulse and Lock-in Phase Infrared Thermography (광원 펄스와 위상잠금 적외선 열화상을 이용한 점용접부의 건전성 평가 연구)

  • Park, Hee Sang;Choi, Mang Yong;Kwon, Koo Ahn;Park, Jeong Hak;Kim, Won Tae;Lee, Bo Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.4
    • /
    • pp.349-354
    • /
    • 2013
  • The non-destructive testing using infrared thermography is extended to a variety of industries and non-destructive testing of welds using infrared thermography is also in progress in various ways. Currently, a non-destructive testing of electrical resistance spot welds which is mainly used is Radiography Testing. This study detected area of spot welds nugget using optical-infrared thermography. In the results, it is possible for detecting defects of nugget in a short period of time using pulse-infrared thermography.

Blue-Light Hazards of 405 nm Sterilization LED Lamps (405 nm 살균용 UV LED 등기구의 청색광 위해에 관한 연구)

  • Hyeon-seok Heo;Chung-hyeok Kim;Ki-ho Nam;Jin-sa Kim
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.3
    • /
    • pp.266-274
    • /
    • 2023
  • Recently, sterilization technology has received increasing interest due to the COVID-19 pandemic and required safety precautions. Particularly, sterilization devices using near ultraviolet (UV) with a 405 nm wavelength are also drawing attention. It has a UV-C wavelength and other sterilization effects. Its blue-colored light on the boundary between UV and visible light is used as a light-emitting diode (LED) lamp for 405 nm sterilization, owing to its longer wavelengths than UV rays. However, the 405 nm wavelength contains blue light that can damage the eyes and skin during prolonged exposures and affect the emotional and biological parts of the body. Currently, 405 nm sterilization LED light registers are circulating in the market. However, they have not undergone safety tests for blue-light hazards. Thus, with the active distribution of sterilization LED lights, solid safety standards and management systems are essential to protect users from blue-light hazards. Accordingly, in this study, we conducted spectral radiance and spectral radiative luminance tests on 405 nm sterilization LED registers available in the market by the measurement criteria of IEC 62471. Safety standards must be established to secure users' safety against blue light hazards at a time when 405nm sterilization LED lights are actively distributed due to COVID-19.

A Study of Explosion Hazard Proof Modeling for Risk Minimization to Semiconductor & FPD Manufature Equipment and Clean Room (반도체·FPD 제조설비와 클린룸의 RISK 최소화를 위한 폭발위험장소 설정 모델링에 관한 연구)

  • Noh, HyunSeok;Woo, InSung;Hwang, MyungHwan;Woo, JungHwan
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.1
    • /
    • pp.78-85
    • /
    • 2018
  • In this study, we analyzed risks of the fabrication process equipment and cleanroom for semiconductor/flat panel display (FPD) manufacturing facilities and studied the fundamental safety measures for the risk factors. We examined the explosion proof design models considering the specificity of equipment and environment, and planned to utilize the findings to provide technical standards and grounds for designing and manufacturing related equipment. We believe that this study will contribute to the establishment of technical standards for semiconductor/FPD industry and businesses in many different ways by providing optimized modeling of high-risk explosion site detection, developing safety standards and hazard countermeasures and voluntary activation of safety certification system for operation of fabrication process equipment.

Globalization of Korean Electrical Installations Standards and Codes Based on Comparison of IEC 60364 with NFPA

  • Ki, Chung-Young;Ro, Kwak-Hee;Seop, Shin-Hyo;Joo, Nam-Taik
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.118-125
    • /
    • 2001
  • Most of the laws and standards relevant to technology in Korea bear a resemblance to those in Japan. Electricity was not introduced to Korea until Lighting ceremony in Kyong-Bok palace observed in 1887. Since Korea was annexed to Japan in 1910 and our public works were under Japan control we have applied Japanese laws and regulations made by Chosun government-general. Independently from Japan the power electricity accepted power plants of USA, codes of NESC, ASME / ANSI, NEMA. Our generation and distribution system takes American style while our consumer side takes Japanese style. As global trade system was transferred GATT into WTO, the harmonization of technological standards, certification construction testing in the trend of world. This paper is based on WTO / TBT agreement coming in effect after 12th, April, 1979. For Korea the distribution system has a strong resemblance to American system so that unconvertible because IEC 60364 originated from Europe while NEC originated from USA. This papers deals with the fundamental elements of electrical safety system with comparing IEC 60364 with NEC. This paper considers how engineers should apply NFPA 70(NEC) and IEC based on the comparison of NEC to IEC in relation to electrical installations.

  • PDF

Assessment of Electrical Safety for Grounding System by Investigation on the Spot (현장조사에 의한 접지시스템의 전기안전성 평가)

  • Gil, Hyoung-Jun;Kim, Dong-Woo;Kim, Dong-Ook;Lee, Ki-Yeon;Kim, Hyang-Kon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.361-364
    • /
    • 2008
  • This paper deals with assessment of electrical safety for grounding system of buildings by investigation on the spot at construction site. The investigation was carried out for grounding method, grounding type, shape of grounding electrode, grounding for lightning protection system, continuity of steelwork in reinforced concrete structure and so on. The investigation on the spot was performed by researcher, engineer with over fifteen years of industry experience all over the country. As a result of investigation on the spot to 13 buildings, common grounding method was dominant. A new grounding system based on international standards includes unity grounding system, structure grounding utilizing steel reinforced concrete, equipotential bonding. use of surge protective device.

  • PDF

An Investigation of Health and Safety Measures in a Hydroelectric Power Plant

  • Acakpovi, Amevi;Dzamikumah, Lucky
    • Safety and Health at Work
    • /
    • v.7 no.4
    • /
    • pp.331-339
    • /
    • 2016
  • Background: Occupational risk management is known as a catalyst in generating superior returns for all stakeholders on a sustainable basis. A number of companies in Ghana implemented health and safety measures adopted from international companies to ensure the safety of their employees. However, there exist great threats to employees' safety in these companies. The purpose of this paper is to investigate the level of compliance of Occupational Health and Safety management systems and standards set by international and local legislation in power producing companies in Ghana. Methods: The methodology is conducted by administering questionnaires and in-depth interviews as measuring instruments. A random sampling technique was applied to 60 respondents; only 50 respondents returned their responses. The questionnaire was developed from a literature review and contained questions and items relevant to the initial research problem. A factor analysis was also carried out to investigate the influence of some variables on safety in general. Results: Results showed that the significant factors that influence the safety of employees at the hydroelectric power plant stations are: lack of training and supervision, non-observance of safe work procedures, lack of management commitment, and lack of periodical check on machine operations. The study pointed out the safety loopholes and therefore helped improve the health and safety measures of employees in the selected company by providing effective recommendations. Conclusion: The implementation of the proposed recommendations in this paper, would lead to the prevention of work-related injuries and illnesses of employees as well as property damage and incidents in hydroelectric power plants. The recommendations may equally be considered as benchmark for the Safety and Health Management System with international standards.

A Study on Development of Guideline on Writing Technical Document for Electrical Medical Devices : Bone Absorptiometric X-ray System (엑스선골밀도측정기의 기술문서 작성을 위한 가이드라인 개발 연구)

  • Lee, Seung-Youl;Kim, Jae-Ryang;Kim, Eun-Rim;Lee, Jun-ho;Lee, Chang-Hyung;Park, Chang Won
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.263-271
    • /
    • 2016
  • The market size of the bone absorptiometric X-ray system and the number of its approval by Ministry of Food and Drug Safety (MFDS) has annually increased, with a trend of increasing aging population and osteoporosis patients. For approval of manufactured or imported medical devices in Republic of Korea, it is required to submit its technical document. Therefore, it is need to develop the technical document guideline for the bone absorptiometric X-ray system for manufacturers, importers and reviewers. First of all, the technical documents which were already approved were examined and analyzed through MFDS approval administration system. Second, safety and performance test standards and methods that match international standards were drawn after conducting survey of the market status and the technology development trend for it, with examination and analysis of applicable domestic and overseas standards. Third, by operating industry-research-government cooperation, the guideline draft on writing technical document for the bone absorptiometric X-ray system was discussed, collecting their opinion. As a result, it is suitable to international and domestic condition, includes test evaluation methods and offer various information with appropriate examples to civil petitioner, when they write the technical documents.

Problems and Inprovement Method of Grounding System in Electrical Facilities (건축전기설비에 적용되는 접지시스템 문제점과 개선방안)

  • Chung, Young-Ki;Kwak, Hee-Ro;Shin, Hyo-Sub;Chung, Chun-Byoung;Nam, Taik-Joo
    • Electric Engineers Magazine
    • /
    • v.228 no.8
    • /
    • pp.52-57
    • /
    • 2001
  • Presently the Korean grounding system uses TN system, multi-grounding method with IT independent grounding method. Nevertheless TN system can't exist with TT system in the technological terms. If they coexist, it causes ground-fault circuit not to operate, and brings about different electrical potential rise by customer system. It brings about serious problems for safety. This paper aims for improving method of grounding system based on the technical analysis on instances in foreign countries and Korea. Almost standards and construction manner were apt to be internationalized after WTO/TBT agreement was concluded. The internal grounding systems should meet the international criteria and reliability for safety, and be provided with technologically impeccable standards.

  • PDF

Feasibility Study on the Use of Vegetable Oil (Natural Ester) in Malaysia Power System Transformers

  • Suleiman, Abubakar A.;Muhamad, Nor Asiah Binti
    • Transactions on Electrical and Electronic Materials
    • /
    • v.15 no.3
    • /
    • pp.113-116
    • /
    • 2014
  • Power transformer insulation oil is critical to the useful life of the transformer. Although mineral base insulation oil is the most common type of transformer insulation oil in use, environmental and safety concerns has encouraged the development of biodegradable alternatives. Today, $Envirotemp^{(R)}\;FR3^{TM}$ is in commercial use and this study is aimed at ascertaining the possibility of applying the oil in Malaysia power transformers. A sample of $Envirotemp^{(R)}\;FR3^{TM}$ was tested to measure and compare the technical (including electrical, chemical and physical) properties of the oil according to Malaysian standards. The study found that the oil sample had better qualities, such as higher dielectric strength, lower dissipation factor, higher flash and fire points, higher moisture absorption capability, and less dissolved gases composition amongst others. However, it was also ascertained that further development in this area could be hindered due to Malaysia's lack of standards for biodegradable oil.