• 제목/요약/키워드: Electrical response

검색결과 3,682건 처리시간 0.035초

ANSYS를 이용한 캔형 구조물의 주파수응답특성 해석 (Analysis on the Harmonic Response of Can-type Structure with ANSYS)

  • 서판석;최남호;구경완;김종석;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 연구회
    • /
    • pp.79-83
    • /
    • 2001
  • This is an investigation on the propagation characteristics of AE signal in GIS. The selection of measuring position and resonant frequency of AE sensor is one of the most important factor to optimize a diagnostic system. And natural frequency and harmonic response characteristics are indispensable to optimize those factors. So, in this investigation, we make a 3D model of 362kV GIS and make a modal and harmonic analysis to survey the vibro-acoustic property. Through the result of the analysis, we can make a further understanding on the vibro-acoustic characteristics of GIS.

  • PDF

확장성표기언어 기반의 LED 조광제어 플랫폼에 관한 연구 (A Study on LED Dimming Control Platform Based on XML)

  • 최중인;고원석
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.22-27
    • /
    • 2012
  • In the study, an XML based platform is presented for LED dimming control. The XML platform is designed in an open architecture, providing with interoperability and scalability. Also, it enables the accommodation of off-the-shelf wired and wireless communication protocols and make it fast and easy to implement various application programs for LED dimming, comparing to the legacy platforms. In the study, a test best has been built for demonstration of the merits of the XML platform with dimming control by responding to the scenario of demand response event. Benefit calculation of the power saving and incentive from demand response shows the applicability and usefulness of the XML platform.

퍼지 로직 및 모델 예측 제어기 적용을 통한 초초임계압 화력발전소 부하 응답 최적화 운전 방법 설계 (Unit Response Optimizer mode Design of Ultra Super Critical Coal-Fired Power Plant based on Fuzzy logic & Model Predictive Controller)

  • 오기용;김호열
    • 전기학회논문지
    • /
    • 제57권12호
    • /
    • pp.2285-2290
    • /
    • 2008
  • Even though efficiency of coal-fired power plant is proportional to operating temperature, increasement of operating temperature is limited by a technological level of each power plant component. It is an alternative plan to increase operating pressure up to ultra super critical point for efficiency enhancement. It is difficult to control process of power plant in ultra super critical point because that point has highly nonlinear characteristics. In this paper, new control logic, Unit Response Optimizer Controller(URO Controller) which is based on Fuzzy logic and Model Predictive Controller, is introduced for better performance. Then its performance is tested and analyzed with design guideline.

RSM을 이용한 CVVT용 전동기 코깅토크 저감 설계 (Cogging Torque Reduction Design for CVVT Using Response Surface Methodology)

  • 김재의;김동민;박수환;홍정표
    • 전기학회논문지
    • /
    • 제65권12호
    • /
    • pp.2183-2188
    • /
    • 2016
  • This paper deals with the design process for an outer-rotor-type surface-mounted permanent magnet synchronous motor (SPMSM) used in continuous variable valve timing (CVVT) systems in automobiles with internal combustion engines. When the same size, outer-rotor-type SPMSMs generate larger torque and more stable than inner-rotor-type SPMSMs. For the initial design, space harmonic analysis (SHA) is used. In order to minimize the cogging torque, an optimization was conducted using Response Surface Methodology (RSM). At the end of the paper, Finite Element Analysis (FEA) is performed to verify the performance of the optimum model.

Study on Failure Diagnosis of Power Transformer Using FRA

  • Sano, Takahiro;Miyagi, Katsunori
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.324-329
    • /
    • 2006
  • As the average usage period of transformers increases, it is becoming increasingly necessary to know the internal condition of transformers. It is therefore critically important to establish monitoring and diagnostic techniques that can perform transformer condition assessment. Frequency response analysis, generally known as FRA, is one of the technologies to diagnose transformers. Using case studies, this paper presents the effectiveness of FRA as measurements for detecting transformer failures. This paper introduces the fact that FRA waveforms have useful information about diagnosis of failure on core earths and winding shield, and that the condition outside transformers can affect frequency response characteristics.

감압경수형 원자로의 최적부하추종제어에 관한 연구 (A Study of Optimal Load Follow Control in Pressurized Water Reactors)

  • 김락규;박상휘
    • 대한전기학회논문지
    • /
    • 제34권12호
    • /
    • pp.491-497
    • /
    • 1985
  • An applicaton of the linear optimal control theory to the problem or load follow control in pressurized water reactors (PWR) is investigated. In order to perform the steady-state and load follow operation in PWR, a nonlinear model for the reactor and steam generator is derived and linearized at 50% rated power. Simulation tests are performed for 10% demanded load. Comparing the dynamic response of the newly developed optimal load follow controller with those of the integral error feedback controller proposed by Yang, the rise time of dynamic response of the former is about 15 seconds faster than those of the latter, thus the results indicate that the fast response of the optimal load follow controller is verified. The results of this work are directly applicable to the design of the load follow control systems for commercially operated PWRs.

  • PDF

CDIDF로기전된 비선형신형기에 의한 직유전동기의 속도제어 (Speed Control of DC Motor by a Nonlinear Compensator Describing the CDIDF)

  • Hyoung-Ki Lee;Hong-Gon Ha;Byung-Do Yoon
    • 대한전기학회논문지
    • /
    • 제37권2호
    • /
    • pp.130-137
    • /
    • 1988
  • The technique of dual-input describing function's synthesis is introduced and the construction of a nonlinear compensator, based on this technique, is proposed. A nonlinear compensator, describing a complex DIDF depending upon amplitude of the second sinusoidal input signal only, is also proposed, where the second sinusoidal input signal is supplied to the nonlinear compensator by external generator. This compensator, connected in a closed loop of the PI speed control of DC motor, can improve the speed response in view instability limit cycle, low speed response and disturbance of the dynamic shift of the Nyquist's critical point -1 + j O. It is verified theoretically that the improvement of speed response of DC motor using the proposed compensator is achieved by means of the dynamic shift of the Nyquist's critical point on the complex plane, and the speed characterstics of DC motor is to be tested through experiment for its performance.

유도형 교류 서보전동기의 고응답 구동회로 설계에 관한 연구 (Design of High-Response Speed Control System for AC Servomotor Drive)

  • 성영권;조철제
    • 대한전기학회논문지
    • /
    • 제41권5호
    • /
    • pp.474-482
    • /
    • 1992
  • This paper describes the speed control system of an induction type ac servomotor drive on the vector control basis of slip frequency and constant secondary flux control for a quick torque response. The system is composed of a digital controller using a SCB-V50 microprocessor and a PWM inverter with power MOSFETs for high speed switching. And, for the measurement of actual instantaneous currents, MDCS A070-051 hall sensors are employed. The rising time of step responce by this system through the test of a 600[W] ac servomotor is 30[ms]. Overall experimental result shows that the drive performance of the system is similar to that of a separately excited armature current control of a dc motior.

  • PDF

균일 리플 통과대역 응답을 갖는 1/3 밴드 FIR 필터의 설계 (A Design Method for Third-Band FIR Filters of Equi-Ripple Passband)

  • 문동욱;김낙교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제54권9호
    • /
    • pp.570-576
    • /
    • 2005
  • In FIR (Finite Impulse Response) filter applications, Nth-band FIR digital filters are known to be important due to their reduced computational requirements. The conventional methods for designing FIR filters use iterative approaches such as the well-known Parks-Mcclellan algorithm. the Parks-Mcclellan algorithm is also used to design Nth-band FIR digital filters. But a disadvantage of the Parks-McClellan algorithm Is that it needs a good amount of design time. This paper describes a direct design method for third-band FIR Filters using Chebyshev polynomial, which provide a reduction in design time over indirect methods such as the Parks-McClellan algorithm. The response of the resulting filter is equi-ripple in passband. The proposed method of design produces a passband response that is equi-ripple to within a minuscule error, compare to that of the Parks-McClellan algorithm.

비편광 UV조사에 의한 광배향 VA-LCD의 전기광학특성 (Electro-optical properties of photo-aligned VA-LCD by irradiation of unpolarized UV light.)

  • 박두석;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.545-548
    • /
    • 1999
  • The electro-optical characteristics of photo-aligned vertical-alignment (VA)-liquid crystal display (LCD) with non-polarized ultraviolet (UV) light irradiation of 45\`on homeotropic polyimide (Pl) surface were investigated. LC alignment on photo-aligned VA-LCD is attributed to photo-depolymerized reaction of the polymer with non-polarized UV light irradiation on PI surface. We had good voltage-transmittance (V-T) characteristics of photo-aligned VA-LCD. The response time of photo-aligned VA-LCD was slower than that of the rubbing-aligned VA-LCD. Finally, we suggest that the slow response time of photo-aligned VA-LCD depends on the LC domain.

  • PDF