• Title/Summary/Keyword: Electrical response

Search Result 3,684, Processing Time 0.03 seconds

A Study on the Effects of Needle Electrode Electrical Stimulation on the Number of c-Fos Response Cells and c-Fos Expression in the Global Ischemic Rats

  • Kim, Sung Won;Song, Young Wha;Lee, Jung Sook
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.7 no.2
    • /
    • pp.1031-1036
    • /
    • 2016
  • c-Fos is known to related to synaptic plasticity and apoptosis in damage from ischemia or external injury. The purpose of this study was to investigate whether needle electrode electrical stimulation(NEES) is effective in increasing the number of c-Fos response cells and c-Fos expression in striatum after global ischemia in rats. There were no treatment and occlusion in the control group, global ischemia(GI) group were no treatment after carotid artery occlusion, and needle electrode electrical stimulation(NEES) group were treated with NEES after GI induced. The number of striatum c-Fos response cells and c-Fos protein expression significantly decreased in the NEES group compared to the GI group after 12, 24, 48 hours. The results of the present study suggest that NEES is ineffective in improving global ischemia in rats and may also be ineffective in the globally ischemic human brain.

Detection of Protein Molecules by Electrical Current Response Using Two-Electrode Method

  • Lyu, Hong-Kun;Woo, Sung-Ho;Han, Yoon-Soo;Lee, Hee-Ho;Shin, Jang-Kyoo
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.90-95
    • /
    • 2011
  • In order to protect human lives from disease, various biosensors having the potential to analyze a variety of biomolecules have been utilized. Biosensors constitute one of the most promising ways to monitor and detect various biomolecules corresponding to diseases. In this study, we demonstrate that the reaction of streptavidin molecules with biotin on a gold electrode can be detected using the twoelectrode method with a gold electrode and a platinum reference electrode. We also show the characteristics of the electrical current response. While detecting 2-${\mu}M$ streptavidin molecules dissolved in phosphate buffered saline(PBS) solution, we found that an analytical biosensor can operate on the principle of detecting an antigen-antibody reaction event of protein molecules using the two-electrode method. We think that the "potential step" method might be useful to detect the occurrence of any antigen-antibody reactions and can be combined with other devices or ICs such as BJTs, MOSFETs, and OP-amps for the detection of biomolecules of diseases.

Fabrication and Characteristic of NOx Gas Sensor by Using $SnO_2$ Nanowires ($SnO_2$ 나노와이어를 이용한 NOx 가스센서 제작 및 특성평가)

  • Kang, Gyo-Sung;Kwon, Soon-Il;Park, Jea-Hwan;Yang, Kea-Joon;Lim, Dong-Gun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.40-41
    • /
    • 2007
  • $SnO_2$ nanowires are used at the nanoscale level for the electrical transduction of the gas interaction with these sensing materials. We report on a study of high sensitivity and fast NOx gas sensor. We focused on improving the response time and refresh time by growth nanowires on the trench structure of Si substrate as air path. To improve refresh time we applied the trench structure with depth of $10\;{\mu}m$ by the inductively coupled plasma reactive ion etching(ICP-RIE). The fabricated device was measured at temperature of $200{\sim}300^{\circ}C$. The sensor exhibit ultra-fast and reversible electrical response (t90% ~4 s for response and ~3 s for recovery).

  • PDF

Evaluation of MCC seismic response according to the frequency contents through the shake table test

  • Chang, Sung-Jin;Jeong, Young-Soo;Eem, Seung-Hyun;Choi, In-Kil;Park, Dong-Uk
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1345-1356
    • /
    • 2021
  • Damage to nuclear power plants causes human casualties and environmental disasters. There are electrical facilities that control safety-related devices in nuclear power plants, and seismic performance is required for them. The 2016 Gyeongju earthquake had many high-frequency components. Therefore, there is a high possibility that an earthquake involving many high frequency components will occur in South Korea. As such, it is necessary to examine the safety of nuclear power plants against an earthquake with many high-frequency components. In this study, the shaking table test of electrical facilities was conducted against the design earthquake for nuclear power plants with a large low-frequency components and an earthquake with a large high-frequency components. The response characteristics of the earthquake with a large high-frequency components were identified by deriving the amplification factors of the response through the shaking table test. In addition, safety of electrical facility against the two aforementioned types of earthquakes with different seismic characteristics was confirmed through limit-state seismic tests. The electrical facility that was performed to the shaking table test in this study was a motor control center (MCC).

A Hybrid Bilayer Pressure Sensor based on Silver Nanowire (은 나노와이어 기반 하이브리드 이중층 압력 센서)

  • Lee, Jin-Young;Shin, Dong-Kyun;Kim, Ki-Eun;Seo, Yu-Seok;Park, Jong-Woon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.3
    • /
    • pp.31-35
    • /
    • 2017
  • We have fabricated flexible and stretchable pressure sensors using silver nanowires (AgNWs) and analyzed their electric responses. AgNWs are spray coated directly onto uncured polydimethylsiloxane (PDMS) such that AgNWs penetrate into the uncured PDMS, enhancing the adhesion properties of AgNWs. However, the single-layered AgNW sensor exhibits unstable electric response and low pressure sensitivity. To tackle it, we have coated a conductive polymer, poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) onto the AgNW layer. Such a hybrid bilayer sensor ensures a stable electric response because the over-coating layer of PEDOT:PSS effectively suppresses the protrusion of AgNWs from PDMS during release. To enhance the sensitivity further, we have also fabricated a stacked bilayer AgNW sensor. However, its electric response varies depending sensitively on the initial overlap pressure.

  • PDF

Computational Speed Comparison between FFT Convolution and Recursive Filtering

  • Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1979.08a
    • /
    • pp.166-167
    • /
    • 1979
  • Performances of three computational algorithms for one-dimensional frequency filtering are compared and tradeoffs are studied. If the size of the filter impulse response is small, it is well-known that the conventional convolution is superior than the FFT convolution. If the size of the impulse response is large, it was suggested that the recursive filter might be competitive in terms of speed to the FFT convolution. We, therefore, have developed an computational, algorithm for the recursive filter to compare the speed advantages over the FFT convolution and the results are presented.

  • PDF

An Improved Incremental Conductance MPPT Method for the Photovoltaic Generation

  • Wellawatta, Thusitha;Choi, Sung-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2016.07a
    • /
    • pp.185-186
    • /
    • 2016
  • Maximum power point tracking (MPPT) techniques play a big role in improving the efficiency of photovoltaic (PV) system. Among various schemes, the incremental conductance (INC) method is mostly discussed in literature because of its fast response to the rapid irradiation changes and high tracking accuracy. However, the existing INC algorithm has trade-offs between fast dynamic response and steady state stability. This study proposes a novel INC method to meet high efficiency and fast tracking performance at the same time.

  • PDF

Installation of Measuring System for the Transient Ground Impedances using Portable Impulse Current Generator (이동식 ICG를 이용한 과도접지임피던스 측정 시스템 구축)

  • Lee, Tae-Hyung;Cho, Sung-Chul;Eom, Ju-Hong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.199-201
    • /
    • 2007
  • This paper presents the installation of measuring system for the transient behaviors of grounding system impedances using portable impulse current generator. The measuring system is controller, with controller, power supply, impulse current generator and data aquisition system. In the evaluation of the impulse response in a ground electrode, the step response is calculated based on the ratio of the voltage and current observed.

  • PDF

The comparison of ESD prevention characteristic of TVS with a Varistor at low voltage (저압회로에서의 TVS와 Varistor의 ESD 방지특성 비교)

  • 최홍규;송영주;이완윤
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.105-109
    • /
    • 2002
  • A TVS and Varistor are preservative equipment against electro static discharge(ESD). We use a TVS for I/O protection of a circuit which has faster response time than a Varistor. And a Varistor has large power capability, therefore, which be used in input stage for internal pressure prevention. This paper will compare a TVS with a Varistor with respect to response characteristic to ESD in DC 24[V] low voltage circuit.

  • PDF

An algorithm of detecting changed intervals with step-type shape in motor's speed response data (모터 스텝 응답에서 변동 구간 검출 기법)

  • Kim, Tae-Eun;Lee, Hai-Young
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.309-313
    • /
    • 2004
  • This paper presents an algorithm of detecting changed intervals with step-type shape in motor's speed response data. The proposed method is composed of 4 parts such as noise filtering, decision making of reference value's change, finding entrance point of steady state and detecting changed intervals. According to simulation results for three cases, we see that changed intervals can be found well.

  • PDF