분산형 사고파형저장 시스템에 대한 연구 (The Study of Distributed Disturbance Recording System)

  • 박종찬;이세인
    • 전기학회논문지P
    • /
    • 제57권1호
    • /
    • pp.30-35
    • /
    • 2008
  • In this paper, the application of power Quality monitoring based on Sampled Value(SV) which is introduced in the IEC61850 International Standard for substation communication are discussed. Firstly, while Merging Unit(MU) is designed as a process level device transmitting sensor data, the practical problems such as time delay compensation and optical fiber communication are encountered. Secondly, the Sampled Value message which is proper to a power quality monitoring system is presented. Because the power quality monitoring system requests less time-critical service compared to protection and control applications, the Sampled Value service message structure is introduced to improve efficiency. Lastly, the power quality monitoring server having various power quality analysis functions is suggested to verify the performance of Merging Unit With the diverse experiments, it is proved that the process bus distributed solution is flexible and economic for the power quality monitoring.

FCM과 ELM을 이용한 전력용 변압기의 모니터링 알고리즘 (A Monitoring Algorithm using FCM and ELM for Power Transformer)

  • 지평식;임재윤
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.228-233
    • /
    • 2012
  • In power system, substation facilities have become too complex and larger according to an extended power system. Also, customers require the high quality of electrical power system. However, some facilities become old and often break down unexpectedly. The unexpected failure may cause a break in power system and loss of profits. Therefore it is important to prevent abrupt faults by monitoring the condition of power systems. Among the various power facilities, power transformers play an important role in the transmission and distribution systems. In this research, we develop intelligent diagnosis technique for monitoring of power transformer by FCM(Fuzzy c-means) and ELM(Extreme Learning Machine). The proposed technique make it possible to diagnosis the faults occurred in transformer. To demonstrate the validity of proposed method, various experiments are performed and their results are presented.

계통 연계 대관령 풍력실증단지에서의 전력 품질 모니터링 (A Power Quality Monitoring of The Grid-connected Wind Turbine in Daegwallyeong Test Site)

  • 권혁준;김광호;장성일;유능수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1513-1515
    • /
    • 2004
  • This paper describe the power quality monitoring results of the grid-connected wind turbine generator in Daegwallyeong Test Site. The power quality monitoring for grid-connected wind turbine generators are important to verify their performance as the grid-connected generators. In order to measure the impacts on the grid of wind turbine generator and evaluate the performance by analyzing electrical parameters, we equipped the power quality monitoring system in the real field of the Daegwallyeong test site. The developed monitoring system gathers information by remote access through the internet. The monitoring results and the detail explanation for the developed wind turbine monitoring system is presented in the study.

  • PDF

Load Profile Disaggregation Method for Home Appliances Using Active Power Consumption

  • Park, Herie
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권3호
    • /
    • pp.572-580
    • /
    • 2013
  • Power metering and monitoring system is a basic element of Smart Grid technology. This paper proposes a new Non-Intrusive Load Monitoring (NILM) method for a residential buildings sector using the measured total active power consumption. Home electrical appliances are classified by ON/OFF state models, Multi-state models, and Composite models according to their operational characteristics observed by experiments. In order to disaggregate the operation and the power consumption of each model, an algorithm which includes a switching function, a truth table matrix, and a matching process is presented. Typical profiles of each appliances and disaggregation results are shown and classified. To improve the accuracy, a Time Lagging (TL) algorithm and a Permanent-On model (PO) algorithm are additionally proposed. The method is validated as comparing the simulation results to the experimental ones with high accuracy.

LabVIEW를 이용한 철도 선로전환기 융설용 태양광-풍력 발전 모니터링 시스템의 적용 방법 (The Application of Monitoring System Methods of Photovoltaic-Wind Power Generation for Railway Switching Point Heating Using LabVIEW)

  • 김대년;김덕현;최정원
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.9-14
    • /
    • 2013
  • The monitoring system is an absolutely required system for improving a performance to consider the situation for the hybrid generation of the photovoltaic (PV) and wind power (WP) energy experimental research complex. This system is to monitor with the railroad switching point heating system using LabVIEW to the hybrid generation of the PV and WP. The monitoring system of this paper is a program monitoring the hour, day and total of the voltage and current that made from the hybrid generation of PV and WP. In experiment, we acquired the power data according to time at the day of PV and WP. We have confirmed the possibility of the real time monitoring system using LabVIEW with the railroad switching point heating system as the hybrid generation of the PV and WP.

광역 방어시스템의 통신 트래픽 모사와 분석 (Simulation and Analysis of the Network Traffic of a Power Infrastructure Defense System)

  • 백윤기;이건영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.179-180
    • /
    • 2006
  • The real time monitoring of the power systems covering wide area are essential for the stable operation and control of the power system. Synchronized phasor measurement is a key for the precise monitoring and control of the power systems. In this paper, to suggest an appropriate network topology of Power Infrastructure Defense System(PIDS) and to estimate the maximum network bandwidth with using the network analyzer, we simulate a PIDS and analyze the network traffic.

  • PDF

능동 데이터베이스 기반 무효전력 보상장치 감시제어 시스템 (A Reactive Power Compensation Monitoring System for Factory Electrical Installation Using Active Database)

  • 최상열
    • 한국인터넷방송통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.189-194
    • /
    • 2012
  • 수배전 무효전력 보상 감시 제어시스템은 수배전단에 설치된 유도 모터, 또는 아크 용접기 등과 같은 유도성 부하에서 발생되는 지상무효전력을 보상하고 역률의 개선, 전압 강하의 경감, 전력손실을 감소 시켜줌으로써 전력설비 계통을 경제적이고 안정적으로 운영하도록 도와준다. 그리고 이러한 시스템은 중앙전력감시반이 획득한 수변전설비의 운전상태 및 계측 Data를 근거로 역률 및 위상각을 분석하여 기준 위상각이상으로 전압과 전류의 위상차가 발생 되었을 경우, 무효전력 보상장치의 ON/OFF제어를 수행하여 효율적인 계통관리가 가능하도록 한다. 본 연구에서는 능동데이터베이스를 이용하여 무효전력 보상장치 감시제어 시스템을 구현하는 방안을 제시함으로써, 공장 부하의 지상무효전력이 급격한 증가로 인한 역률 저하, 전압 강하, 손실 발생 등의 징후 발생 시 이에 대한 대처를 사용자(operator)의 개입 없이 데이터베이스 스스로 수행하도록 함으로써 인위에 의한 실수를 최소화 하도록 하였다.

온도센서를 이용한 전력설비의 온라인 상태 감시 (On-Line Condition Monitoring of Electrical Equipment Using Temperature Sensor)

  • 최용성;김선재;김영민;송환기;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.202-208
    • /
    • 2008
  • Condition monitoring technologies allow achieving this goal by minimizing downtime through the integrated planning and scheduling of repairs indicated by condition monitoring techniques. Thermal runaways induced by conduction problems deteriorate insulating material and cause disruptive dielectric discharges resulting in arcing faults. Therefore, having the ability to directly measure the temperature of the contacts while in service will provide more information to determine the true condition of the equipment. It allows connective measures to be taken to prevent upcoming failure. Continuous temperature monitoring and event recording provides information on the energized equipment's response to normal and emergency conditions. On-line temperature monitoring helps to coordinate equipment specifications and ratings, determine the real limits of the monitored equipment and optimize facility operations. Using wireless technique eliminates any need for special cables and wires with lower installation costs if compared to other types of online condition monitoring equipment. In addition, wireless temperature monitoring works well under difficult conditions in strategically important locations. Wireless technology for on -line condition monitoring of energized equipment is applicable both as stand alone system and with an interface for power quality monitoring system. The paper presents the results of wireless temperature monitoring: of electrical equipment at a power plant.

분전반 통합 감시 시스템 개발 (Development of the Integrated Monitoring System for Panel boards)

  • 김일권;조현경;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.347_348
    • /
    • 2009
  • In this paper, we described the integrated monitoring system for low-voltage panel boards. This system consists of three parts, a panel board controller, an integrated monitoring unit and a remote PC. The panel board controller which was made of CT/PT unit, control unit and power supply is able to transmit variable parameter for monitoring and diagnosis of low voltage branch circuits. Also, the integrated monitoring unit was collected monitoring data from panel boards and displayed on the touch panel.

  • PDF

모니터 기능을 갖는 통신기기용 전원 시스템 (Power supply system of the telecommunication equipment with monitoring function)

  • 이중기;김영태;김창선;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.309-311
    • /
    • 1995
  • Recently, a power supply system of the telecommunication equipments with monitoring function has been widely studied. In the power supply system which is apart from the central station, it is required to check and test the operating states of the system at the central station. In this paper, the power supply system with monitoring function is discussed. In the system, the Full-Bridge converter is designed as a power supply and it has the ratings of DC 280-340V input and DC 48V, 480W output. And the monitoring part of the system is composed of a voltage and current sensing unit A/D converter, I/O card, and a personal computer. The operating states of the system is monitored by checking the voltage and current variation at input and output, and it is represented by graphical modes. By conducting the experiment, it is confirmed that the operating states of the system is well monitored.

  • PDF