• 제목/요약/키워드: Electrical power monitoring

검색결과 903건 처리시간 0.025초

전력 케이블의 최근 연구 및 기술 동향 (Recent research and technical trend of power cable system)

  • 김동욱;최명규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.616-618
    • /
    • 2000
  • This paper describes the recent research and technical trend of power cable system. Compact sizing with long length and large capacity is the main trend of the power cable. From the manufacturing process to the monitoring of the underground power line, various new techniques are being developed for reliability and high quality such as in-line monitoring system, triple common extrusion, PD measurement system, new type completion test, etc.

  • PDF

교란들의 인과관계구현 데이터구조에 기초한 발전소의 고장감시 및 고장진단에 관한 연구 (Power Plant Fault Monitoring and Diagnosis based on Disturbance Interrelation Analysis Graph)

  • 이승철;이순교
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권9호
    • /
    • pp.413-422
    • /
    • 2002
  • In a power plant, disturbance detection and diagnosis are massive and complex problems. Once a disturbance occurs, it can be either persistent, self cleared, cleared by the automatic controllers or propagated into another disturbance until it subsides in a new equilibrium or a stable state. In addition to the Physical complexity of the power plant structure itself, these dynamic behaviors of the disturbances further complicate the fault monitoring and diagnosis tasks. A data structure called a disturbance interrelation analysis graph(DIAG) is proposed in this paper, trying to capture, organize and better utilize the vast and interrelated knowledge required for power plant disturbance detection and diagnosis. The DIAG is a multi-layer directed AND/OR graph composed of 4 layers. Each layer includes vertices that represent components, disturbances, conditions and sensors respectively With the implementation of the DIAG, disturbances and their relationships can be conveniently represented and traced with modularized operations. All the cascaded disturbances following an initial triggering disturbance can be diagnosed in the context of that initial disturbance instead of diagnosing each of them as an individual disturbance. DIAG is applied to a typical cooling water system of a thermal power plant and its effectiveness is also demonstrated.

무인항공기용 전원모니터링장치 설계 및 검증에 관한 연구 (A Study on Design and Verification of Power Monitoring Unit for Unmanned Aerial Vehicle)

  • 우희채;김용태
    • 한국항공우주학회지
    • /
    • 제48권4호
    • /
    • pp.303-310
    • /
    • 2020
  • 본 논문은 무인항공기 전기시스템을 위한 전원모니터링장치에 대해서 기술하고 있으며, 무인항공기에 장착되는 AC/DC 발전기, 전원변환기, 배터리 및 기어박스의 데이터 측정과 임무장비의 전원 ON/OFF 장치를 운용하는 전원모니터링장치에 대한 설계를 기술하였다. 전원모니터링장치는 비행체 전원(발전기, 전원변환기 및 배터리)에 대한 전압과 전류를 측정하고, 기어박스의 압력과 온도를 측정하며, 임무컴퓨터로부터 수신된 임무장비의 전원명령을 수행한다. 전원모니터링장치는 무인항공기 비행체 요구사항을 만족하도록 설계하였으며, 구조/열 해석, 환경/EMI 및 지상/비행시험을 통하여 검증을 수행하였다.

전력 IT Cyber Security 연구 동향 (Study Tendency of Cyber Security in Power IT Area)

  • 김학만;박재세;김상남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.205-206
    • /
    • 2008
  • Electrical Power System is very important infrastructure in the country. The functions of control, monitoring and so on in the electrical power system are implemented by information technologies(IT) through cyber space. Recently, many activities for enhancing cyber security in the world. In this paper, we introduce the study tendency of cyber security in power IT areas.

  • PDF

모바일 이용 가능형 ESMS 기능의 단상 분전반 개발 연구 (Development of Single Phase Cabinet Panel with Electrical Safety Monitoring System by Mobile)

  • 김기현;이상익;신성수;배석명
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.92-96
    • /
    • 2011
  • In this paper, in order to reduce the electrical disaster such as electrical fire at traditional markets, we need to develop the ESMS(electrical safety monitoring system) which is able to monitor the power status of electrical equipments. Therefore, for solving the those problems, we developed the detection censor(ZCT, CT) and equipment of data analysis and transmission. The detection censor and equipment are able to monitor the electrical equipments condition(over current, leakage current, arc, etc.). We constructed Test-Bed for testing reliability of the ESMS and obtained certification. And we tested the over current, leakage current and arc under the normal condition.

제한된 전원을 사용하는 저전력 시스템 설계 (Design of the low-power system using the limited source)

  • 김도훈;이교성;김용상;박종철;김양모
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.163-165
    • /
    • 2003
  • Over the past several years, the application extent of the real-time systems is being expanded with the progress of civilization. An effort to minimize power consumption at the system is being accomplished in several fields from the design of an analog/digital circuit up to the device level Things of this effort have included the power optimum-technique to minimize power consumption at the digital logic circuit and the dynamic managed skill by means o( the decision of the operating system. In this paper, we designed of low power system by using Power-optimized method. As an effective low-power design, we designed the low power system which it has a monitoring system within the main board and a personal computer.

  • PDF

가속열화 된 CSPE 상태감시법 유효성 평가 (A Study on Practicality of Condition Monitoring Method of Accelerated Thermal Aging CSPE)

  • 이정훈;구철수;김인용;신용덕
    • 전기학회논문지
    • /
    • 제60권11호
    • /
    • pp.2088-2092
    • /
    • 2011
  • The accelerated thermal aging of CSPE(chloro sulfonate polyethylene) of test cables were carried out for the period equal to 10, 20 and 30 years in air at $100^{\circ}C$, respectively. The CSPE cables(TAIHAN electric wire Co. Ltd) which installed in nuclear power plant for three years were used as starting materials. Condition monitering methods of the accelerated thermal aging of CSPE cables were estimated through indenter modulus and OIT(oxidation induction time) of IEC 62582, and those were newly estimated through volume electrical resistivity, ultrasound reflection time, density, FE-SEM(field emission scanning electron microscopy), XPS(x-ray photoelectron spectroscopy), EDS(energy dispersive spectroscopy), and WD-XRF(wavelength dispersive x-ray fluorescence). A new condition monitoring methods of the accelerated thermal aging of CSPE cables were generally coincident with trend of indenter modulus expect EDS, XPS and XRF. A volume electrical resistivity among new condition monitoring methods of the accelerated thermal aging of CSPE cables is excellent. It is considered that life-time of CSPE cable can be predicted through volume electrical resistivity, if CSPE jacket was aged for period such as more than 20 years.

배전반 설비의 온라인 모니터링 및 진단의 동향 (Trend in Off-Line PD Monitoring with HVAC Testing)

  • 윤주효;홍창일;황종선;최용성;이경섭
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.529-530
    • /
    • 2007
  • The paper considers the relation between on-line monitoring and diagnostics on the one hand and high-voltage (HV) withstand and partial discharge (PD) on-site testing on the other. HV testing supplies the basic data (fingerprints) for diagnostics. In case of warnings by on-line diagnostic systems, off-line withstand and PD testing delivers the best possible information about defects and enables the classification of the risk. Because alternating voltage (AC) is the most important test voltage, the AC generation on site is considered. Frequency tuned resonant (ACRF) test systems are best adapted to on-site conditions. They can be simply combined with PD measuring equipment. The available ACRF test systems and their application to electric power equipment -from cable systems to power transformers - is described.

  • PDF

송전 계통 감시 시스템을 위한 취약도 평가 방법 개발 (Vulnerability Evaluation for Monitoring Wide Area Outage in Transmission Systems)

  • 김진환;임일형;이승재;최면송;임성일;김상태;진보건
    • 전기학회논문지
    • /
    • 제59권3호
    • /
    • pp.506-514
    • /
    • 2010
  • Defense systems are needed to prevent catastrophic failures of a power grid due to cascaded events. Cascaded events can be occurred by power flow overload. Especially, it is the most dangerous problem that overload line is outage, because it can make the power system face danger of cascaded. In this paper, vulnerability evaluation for monitoring wide are outage is proposed using by configuration information of transmission systems. This method of vulnerability evaluation is considered direct effect and indirect effect of power flow, especially overload. What is more, it can be used when the configuration of power system changes, as simple fault occurs or maintenance of facility. In the case studies, the estimation and simulation network have been testified and analysed in PSSE and C programming.