• Title/Summary/Keyword: Electrical parameter

Search Result 3,283, Processing Time 0.027 seconds

Optimal Parameter Selection of Power System Stabilizer using Genetic Algorithm (유전 알고리즘을 이용한 전력시스템 안정화 장치의 최적 파라미터 선정)

  • Chung, Hyeng-Hwan;Wang, Yong-Peel;Chung, Dong-Il;Chung, Mun-Kyu
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.6
    • /
    • pp.683-691
    • /
    • 1999
  • In this paper, it is suggested that the selection method of optimal parameter of power system stabilizer(PSS) with robustness in low frequency oscillation for power system using Real Variable Elitism Genetc Algorithm(RVEGA). The optimal parameters were selected in the case of power system stabilizer with one lead compensator, and two lead compensator. Also, the frequency responses characteristic of PSS, the system eigenvalues criterion and the dynamic characteristic were considered in the normal load and the heavy load, which proved usefulness of RVEGA compare with Yu's compensator design theory.

  • PDF

Receding horizon LQG controller with FIR filter

  • Yoo, Kyung-Sang;Shim, Jae-Hoon;Kwon, Oh-Kyu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1992.10b
    • /
    • pp.193-196
    • /
    • 1992
  • When there exist parameter uncertainty, modelling errors and nonminimum phase zeros in control object system. the stability robustness of conventional LQG and LOG/LTR methods are not satisfactory[2, 8]. Since these methods are performed on the infinite horizon, it is very hard to establish exact design parameters and thus they have lots of problems to be applied to real systems, So in this paper we propose RHLQG/FIRF optimal controller which has robust stability against parameter uncertainty, nonminimum phase zeros and modelling errors. This method uses only the information around at present and therefore shows good performance even when we do not know exact design parameters. We here compare LQG and LQG/LTR method with RHLQG/FIRF controller and exemplify that RHLQG/FIRF controller has better robust stability performance via simulations.

  • PDF

Robust H(sup)$\infty$ FIR Sampled-Data Filtering for Uncertain Time-Varying Systems with Lipschitz Nonlinearity

  • Ryu, Hee-Seob;Yoo, Kyung-Sang;Kwon, Oh-Kyu
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.2 no.4
    • /
    • pp.255-261
    • /
    • 2000
  • This paper presents the results of the robust H(sub)$\infty$ FIR filtering for a class of nonlinear continuous time-varying systems subject to real norm-bounded parameter uncertainty and know Lipschitz nonlinearity under sampled measurements. We address the problem of designing filters, using sampled measurements, which guarantee a prescribed H(sub)$\infty$ performance in continuous time-varying context, irrespective of the parameter uncertainty and unknown initial states. The infinite horizon causal H(sub)$\infty$FIR filter are investigated using the finite moving horizon in terms of two Riccati equations with finite discrete jumps.

  • PDF

A Commutation Torque Minimization Method for Brushless DC Motors with Trapezoidal Elecromotive Force

  • Kim, Chang-Gyun;Lee, Joong-Hui;Youn, Myung-Joong
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.476-481
    • /
    • 1998
  • In this paper, a commutation torque minimization method using parameter observer for a brushless DC motor fed by a voltage source inverter is described. In order to investigate the nature of the commutation torque ripple in trapezoidal brushless DC motor, a new model of the motor is proposed. The optimal drive voltage to minimize the ripple torque is represented as a function of the motor parameters. Therefore, the important parameter is estimated by least-square algorithm.

  • PDF

Modeling and Parameter Estimation of Superheater in Thermal Power Plant (화력발전소 과열기 모델링 및 파라미터 추정)

  • Shin, Yong-Hwan;Li, Xin-Lan;Shin, Hwi-Beom
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.600-601
    • /
    • 2010
  • This paper presents the superheater dynamic modeling and parameter estimation for the thermal plant boiler. The temperature control is closely related to the power plant efficiency and boiler life. The dynamic modeling of the superheater and desuperheater is essentially needed and developed by using the heat balance principle. The simulated model outputs are well matched with the actual ones. It is expected that the proposed model is useful for the temperature controller design.

  • PDF

The Analysis of Weibull Distribution after an Accelerated Aging Test of MV Cable (배전케이블의 수트리 가속열화 후 와이블분포 해석)

  • Kim, Jin-Gook;Lim, Jang-Seob;Song, Il-Gun;Kim, Ju-Yong;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.7-11
    • /
    • 2003
  • for many years already, testing laboratories, research institutes and manufactures try to find a reliable water tree accelerated ageing test that is able to show whether a polymer Medium Voltage cable os susceptible to water treeing or not. Test on laboratory samples, model cable designs, and fell size cable are presented. Apart form aging, another important aspect of any accelerated aging test is the right choice of th preconditioning method. THTS paper is the analysis of weibull distribution method after an accelerated aging test of MV(Medium Cable) cable.

  • PDF

Correlation between Electrical Conduction and Dielectric Relaxation in the Glass System $Cul-Cu_2S-Cu_2O-MoO_3$ ($Cul-Cu_2S-Cu_2O-MoO_3$계 유리의 전기전도 및 유전환화와의 상관)

  • 이재형;임기조
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.43 no.7
    • /
    • pp.1152-1157
    • /
    • 1994
  • The glasses were prpared in the system CuI-CuS12TS-CuS12TO-MoOS13T by rapid quenching technique. These glasses have high ionic conductivities at 2$0^{\circ}C$ in the range of 10S0-1T[S/m], and the conductivities increase with increasing CuI and CuS12TS content. The value of activation energy for dielectric relaxation is nearly identical with that for conductivity. The cole-Cole parameter $\beta$ for representation of the distribution of dielectric relaxation times varies the range from 0.92 to 0.96. This parameter has a weak dependence on the composition of glass, and is independent of temperature. The correlation factors P for the glasses shows from 1.1 to 1.7.

  • PDF

A Study of the PSS Parameter setting for 5Kw Motor-Generator Set (5KW 축약 발전기를 대상으로한 PSS 파라미터 정정 연구)

  • Lim, Ik-Hyun;Ryu, Ho-Seon;Kim, Kyung-Chul;Kim, Sae-Yong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.958-960
    • /
    • 1998
  • This paper presents an application of power system stabilizer for a 5Kw Motor-Generator Set. The power system which was consisted of 5Kw Motor-Generator Set. Excitation system, Governor system and PSS was used for the performance test. The method by changing the PSS gain to allocate properly pole-zero positions was used for setting PSS parameter value. The result of the experiment was satisfactory.

  • PDF

Robust control of End order deadbeat current controller considering calculation time delay for UPS inverter (연산시간지연을 고려한 UPS 인버터용 2차 데드비트 전류 제어기의 강인 제어)

  • Kim, Byoung-Jin;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.1056-1058
    • /
    • 2000
  • Deadbeat technique has been proposed as a digital controller for an UPS inverter to achieve the fast response to a load variation and to conserve a very low THD under a nonlinear load condition. This scheme contains a fatal drawback, sensitivity against parameter variation and calculation time delay. This paper proposes a second order deadbeat current controller, which fundamentally solves the calculation time delay problem and certainly guarantees the robustness of the parameter's variation. This is shown theoretically and practically through simulation and experiment.

  • PDF

Experimental Characterization and Signal Integrity Verification of Interconnect Lines with Inter-layer Vias

  • Kim, Hye-Won;Kim, Dong-Chul;Eo, Yung-Seon
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.11 no.1
    • /
    • pp.15-22
    • /
    • 2011
  • Interconnect lines with inter-layer vias are experimentally characterized by using high-frequency S-parameter measurements. Test patterns are designed and fabricated using a package process. Then they are measured using Vector Network Analyzer (VNA) up to 25 GHz. Modeling a via as a circuit, its model parameters are determined. It is shown that the circuit model has excellent agreement with the measured S-parameters. The signal integrity of the lines with inter-layer vias is evaluated by using the developed circuit model. Thereby, it is shown that via may have a substantially deteriorative effect on the signal integrity of high-speed integrated circuits.