The Response to Impulse Signal on Three Phase Transformer using Vector Network Analyzer (벡터 회로망 분석기 측정을 기반으로 한 3상 변압기의 시간영역 펄스 신호에 대한 응답 분석)

  • Kim, Kwangho;Jung, Jongman;Nah, Wansoo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.79-84
    • /
    • 2015
  • Transformer is widely used element on power system and industrial area. Especially the transformers installed at power system are exposed to an environment of arbitrary changed. Thus the prediction of degradation and the analysis of response to impulse are important. To conduct those works, the electrical characteristics of system should be analyzed, effectively. But the analysis of electrical characteristic in electric machine level such as pole and pad-mounted transformer is almost no, thus commercial VNA (Vector Network Analyzer) is used to getting the response in wide frequency range. However, the output power of VNA is usually under 10mW, so verification for effectiveness of measuring electrically large component should be conducted, firstly. Next, after getting total S-parameter of transformer, predicting impulse response can be performed in time-domain with circuit simulator. In this paper, it is introduced that verification effectiveness of VNA using transfer function from SFRA (Sweep Frequency Response Analyzer), firstly. Next, total S-parameter, six by six matix form, was built using measured 2 port S-parameter from vector network analyzer. To get the response to impulse which is defined by IEC 60060-1, time-domain simulation is conducted to ADS (Advenced Design System) circuit simulator.

Hopf Bifurcation Study of Inductively Coupled Power Transfer Systems Based on SS-type Compensation

  • Xia, Chenyang;Yang, Ying;Peng, Yuxiang;Hu, Aiguo Patrick
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.655-664
    • /
    • 2019
  • In order to analyze the nonlinear phenomena of the bifurcation and chaos caused by the switching of nonlinear switching devices in inductively coupled power transfer (ICPT) systems, a Jacobian matrix model, based on discrete mapping numerical modeling, is established to judge the system stability of the periodic closed orbit and to study the nonlinear behavior of Hopf bifurcation in a system under full resonance. The general flow of the parameter design, based on the stability principle for ICPT systems, is proposed to avoid the chaos and bifurcation phenomena caused by unreasonable parameter selection. Firstly, based on the state equation of SS-type compensation, a three-dimensional bifurcation diagram with the coupling coefficient as the bifurcation parameter is established with a numerical simulation to observe the nonlinear phenomena in the system. Then Filippov's method based on a Jacobian matrix model is adopted to deduce the boundary of stable operation and to judge the type of the bifurcation in the system. Then the general flow of the parameter design based on the stability principle for ICPT systems is proposed through the above analysis to realize stable operation under the conditions of weak coupling. Finally, an experimental platform is built to confirm the correctness of the numerical simulation and modeling.

Precision Position Control of PMSM Using Neural Network Disturbance observer and Parameter compensator (신경망 외란관측기와 파라미터 보상기를 이용한 PMSM의 정밀 위치제어)

  • 고종선;진달복;이태훈
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.3
    • /
    • pp.188-195
    • /
    • 2004
  • This paper presents neural load torque observer that is used to deadbeat load torque observer and gain compensation by parameter estimator As a result, the response of the PMSM(permanent magnet synchronous motor) follows that nominal plant. The load torque compensation method is composed of a neural deadbeat observer To reduce the noise effect, the post-filter implemented by MA(moving average) process, is adopted. The parameter compensator with RLSM (recursive least square method) parameter estimator is adopted to increase the performance of the load torque observer and main controller The parameter estimator is combined with a high performance neural load torque observer to resolve the problems. The neural network is trained in on-line phases and it is composed by a feed forward recall and error back-propagation training. During the normal operation, the input-output response is sampled and the weighting value is trained multi-times by error back-propagation method at each sample period to accommodate the possible variations in the parameters or load torque. As a result, the proposed control system has a robust and precise system against the load torque and the Parameter variation. A stability and usefulness are verified by computer simulation and experiment.

The simulation of electrons swarm parameter in He gas is used by Boltzman equation (볼츠만 방정식을 이용한 Helium 가스의 전자군 파라미터 시뮬레이션)

  • 송병두;하성철;김대연
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.155-158
    • /
    • 1998
  • This paper is calculated at electron swarm simulation by Back Prolongation of Boltzmann equation for range of E/N values from 0.1~200[Td], pressure P= 1.0[Torr], temperature T=300[ 。K], the electron swarm parameter(drift velocity, longitudinal . transverse diffusion coefficients, characteristic energy, etc) in He gas is used by electron collision cross section, particularly explicate the simulation technique, and consider electrical conduction characteristic of He gas.

  • PDF

A Study on the Equivalent Circuit and Parameter Estimation of I.M for Steady state. (정상상태시 유도전동기의 등가회로 및 정수산정에 관한 연구)

  • Baek, Soo-Hyun;Kim, Yong
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.80-82
    • /
    • 1988
  • This paper proposed a new equivalent circuit and parameter estimation for I.M, which is different from T type and L type equivalent circuits. By using this circuit, we can analyze the torque of I.M, such as seperately exited D.C Motor, further more, we think that this equivalent circuit is effective to the vector control system for I.M.

  • PDF

$H^{\infty}$ robust adaptive controller design with parameter uncertainty, unmodeled dynamic and bounded noise (파라미터 불확실성,모델 불확실성,한계 잡음에 대한 $H^{\infty}$ 적응제어기 설계)

  • Baek, Nam-Seok;Yang, Won-Young
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.454-456
    • /
    • 1998
  • Traditional adaptive control algorithms are not robust to dynamic uncertainties. The adaptive control algorithms developed previously to deal with dynamic uncertainties do not facilitate quantitative design. We proposed a new robust adaptive control algorithms consists of an $H^{\infty}$ suboptimal control law and a robust parameter estimator. Numerical examples showing the effectiveness of the $H^{\infty}$ adaptive scheme are provided.

  • PDF

Complex Vector Current Control of Grid Connected Inverter Robust for Inductance Variation (인덕턴스 변화에 강인한 계통연계형 인버터의 복소 벡터 전류제어기)

  • Lee, Taejin;Jo, Jongmin;Shin, Changhoon;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1648-1654
    • /
    • 2016
  • This paper analyzes complex vector current control for the enhanced cross-coupling compensation in accordance with parameter variation in grid-connected inverter system, and verifies through simulation and experiment. Complex vector current control is performed in the synchronous reference frame through d-q transformation. It generates cross-coupling components with rotating nominal angular frequency. In general, cross-coupling elements are compensated by decoupling terms added to output of conventional decoupling PI controller. But, it is impossible to compensate them perfectly which transient response is especially deteriorated such as large overshoot and slow tracking, when variation of grid impedance or measurement error occurs. However, complex vector current control can improve stability and response characteristic of current control regardless of the situation as before. Decoupling controller and complex vector controller are represented through complex forms, and these controllers are analyzed by using frequency response in s-domain, respectively. It is verified that complex vector controller has more superior response characteristic than decoupling controller through MATALB, PSIM and experimental in 5kW grid-connected inverter when L filter parameter is varied from 1.1mH to increase double, 2.2mH.

A Drive Strategy of Induction Motor for High Accuracy position Control of Elevator (엘리베이터의 정밀위치제어(精密位置制御)를 위한 유도전동기(誘導電動機) 구동방법(驅動方法))

  • Yoon, Byung-Do;Kim, Yoon-Ho;Jung, Jae-Youn;Chae, Soo-Hyung;Kim, Choon-Sam
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.1215-1217
    • /
    • 1992
  • This Paper described the hish performance position control for elevator using induction motor and driver. In this paper, the suitable Motor specifications for elevator drive are briefly discussed and high accuracy position control for both kinds of control method is analysed considering the parameter variation in the primary and secondary resistances. Since the pre-identified values of the motor constants are used to determine the control inputs, the performance degradation is caused by the parameter variation such as in the motor resistance. Particularly, the value of secondary resistance is considered significant because the control gain to determine the slip frequency is heavily dependent on that. The new proposed method uses on special small input signal for the parameter indentification and is expected to have the high accuracy position.

  • PDF

Kalman-Filter Based Static Load Modeling of Real Power System Using K-EMS Data

  • Lee, Soo-Hyoung;Son, Seo-Eun;Lee, Sung-Moo;Cho, Jong-Man;Song, Kyung-Bin;Park, Jung-Wook
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.304-311
    • /
    • 2012
  • So far, the importance for an accurate load model has been constantly raised and its necessity would be further more emphasized. Currently used load model for analysis of power system in Korea was developed 10 years ago, which is aggregated by applying the statistically estimated load compositions to load models based on individual appliances. As modern appliances have diversified and rapidly changed, the existing load model is no longer compatible with current loads in the Korean power system. Therefore, a measurement based load model is more suitable for modern power system analysis because it can accurately include the load characteristics by directly measuring target load. This paper proposes a ZIP model employing a Kalman-filter as the estimation algorithm for the model parameters. The Kamlan-filter based parameter identification offers an advantage of fast parameter determination by removing iterative calculation. To verify the proposed load model, the four-second-interval real data from the Korea Energy Management System (K-EMS) is used.

Online Parameter Estimation and Convergence Property of Dynamic Bayesian Networks

  • Cho, Hyun-Cheol;Fadali, M. Sami;Lee, Kwon-Soon
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.7 no.4
    • /
    • pp.285-294
    • /
    • 2007
  • In this paper, we investigate a novel online estimation algorithm for dynamic Bayesian network(DBN) parameters, given as conditional probabilities. We sequentially update the parameter adjustment rule based on observation data. We apply our algorithm to two well known representations of DBNs: to a first-order Markov Chain(MC) model and to a Hidden Markov Model(HMM). A sliding window allows efficient adaptive computation in real time. We also examine the stochastic convergence and stability of the learning algorithm.