• 제목/요약/키워드: Electrical insulation coating

검색결과 51건 처리시간 0.03초

Dry Air Gas를 적용한 초고압 Switchgear 절연특성연구 (A Study on Dielectric Strength and Insulation Property of High Voltage Switchgear Applied Dry Air Gas)

  • 정동훈;정영환;서경보;김태한;김정배;이학성
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1731-1737
    • /
    • 2008
  • This paper present the fundamental insulation characteristics of Dry Air gas and insulation coating in high voltage power apparatus. It is known that the dielectric strength. of Dry Air is approximately one-third that of SF6 gas. we attempt that the insulation coating and dry air gas have replaced the SF6 gas as insulation of the switchgear. We proposed the dry air insulated switchgear(DAIS) for High Voltage apparatus. To acquire technology of insulation characteristic improvement made standards for complex insulation structure and conducted simulations and experiments

Influence of Tank Inner Side Dielectric Coating on the Particle Behaviour and Flashover Voltage in SF\ulcorner Gas Insulated System

  • Lee, Bang-Wook;Koo, Ja-Yoon
    • Journal of Electrical Engineering and information Science
    • /
    • 제2권3호
    • /
    • pp.77-81
    • /
    • 1997
  • In his work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when the epoxy resin based dielectric coating was made on he inner side of outer electrode. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various sizes of Cu conducting particle were used under different gas pressures. In order to elucidate the coating effect on the gas insulation, different thickness of dielectric coating has been considered and then the lift-off voltage and flashover voltages have been measured. The results shown that the dielectric coating has a remarkable influence by restraining the movement of particle in GIS system, and thus GIS insulation reliability is noticeably improved.

  • PDF

NiZn Ferrite Coating for Electrical Insulation of MnZn Ferrite Cores

  • Kitamoto, Y.;Yajima, H.;Nakayama, Y.;Abe, M.
    • 한국세라믹학회지
    • /
    • 제38권6호
    • /
    • pp.506-508
    • /
    • 2001
  • The ferrite plating with applying power ultrasound waves of 19.5 kHz and 600W enabled us to encapsulate entirely MnZn ferrite cores for transformers with Ni$\sub$x/Zn$\sub$y/Fe$\sub$3-x-y/O$_4$coating. Supplying a NH$_4$OH solution during the plating broke the limit of the solubility of Ni ions to ferrite-plated films. The electrical resistivity of the NiZn ferrite coating increased with increasing the Ni and Zn content, reaching 2.3${\times}$10$\^$5/Ωcm at the composition of Ni$\sub$0.24/Zn$\sub$0.30/Fe$\sub$2.46/O$_4$. The saturation magnetization was 540 emu/㎤. As a result, the MnZn ferrite cores were successfully encapsulated with the NiZn ferrite coatings for an insulation layer.

  • PDF

전기 절연성능 향상을 위한 폴리머 애자의 표면 특성 연구 (A Study on the Surface Properties of Polymer Insulators for Improving Electrical Insulation Performance)

  • 박용섭;배재성;홍병유;이재형
    • 한국전기전자재료학회논문지
    • /
    • 제34권1호
    • /
    • pp.63-67
    • /
    • 2021
  • In this paper, we investigated the surface properties of polymer insulators to improve electrical insulation performance. First, after washing the polymer insulator in various ways, its contact angle was increased, thereby improving the hydrophobic properties and electrical insulation properties. In addition, TiO2 thin films, which have been used as a photocatalytic material and have been applied to the polymer insulator surface of to enhance the surface and electrical insulating properties. For the sputtering method, the contact angle after coating the TiO2 thin film increased with increasing RF power, but it was lower compared to that before coating, indicating that the hydrophobic properties of the surface were slightly deteriorated. Consequently, the electrical properties of the polymer-insulating material were maintained or improved after the TiO2 thin-film coating.

GIS 절연 신뢰성 향상을 위한 탱크 내면 코팅이 파티클 거동에 미치는 영향 (Effect of the Inner Side Dielectric Coating of the Tank on the Particle Movement for Improving of GIS Insulation Reliability)

  • 이방욱;구자윤;김민규;김익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 추계학술대회 논문집 학회본부
    • /
    • pp.267-269
    • /
    • 1996
  • In this work, the influence of wire type conducting particles on the insulation reliability of GIS has been systematically investigated when outer electrode was dielectric coated by epoxy resin. For this purpose, coaxial cylinder-type electrode was adopted in 362 kV chamber and various size of Cu conducting particle was used and different gas pressure was applied. To prove the coating effect on the gas insulation, different thickness of epoxy coated outer electrode have been considered and the lift-off voltage and flashover voltage have been analyzed. The results show that the dielectric coated electrode has an remarkable influence on the reducing particle behavior in GIS system and enhancing the GIS insulation reliability.

  • PDF

Insulated, Passivated and Adhesively-Promoted Bonding Wire using Al2O3 Nano Coating

  • Soojae Park;Eunmin Cho;Myoungsik Baek;Eulgi Min;Kyujung Choi
    • 마이크로전자및패키징학회지
    • /
    • 제31권2호
    • /
    • pp.1-8
    • /
    • 2024
  • Bonding wires are composed of conductive metals of Au, Ag & Cu with excellent electrical conductivities for transmitting power and signals to wafer chips. Wire metals do not provide electrical insulation, adhesion promoter and corrosion passivation. Adhesion between metal wires is extremely weak, which is responsible for wire cut failures during thermal cycling. Organic coating for electrical insulation does not satisfy bondability and manufacturability, and it is complex to apply very thin organic coating on metal wires. Automotive packages require enhanced reliability of packages under harsh conditions. LED and power packages are susceptible to wire cut failures. Contrary to conventional OCB behaviors, forming gas was not required for free air ball formation for both Ag and Pd-coated Cu wires with Al2O3 passivation.

나노하이브리드 절연코팅 수지의 내열특성 (Thermal Properties of Insulation Coating Resin by Nanohybrid Method)

  • 한세원;강동필
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.275-275
    • /
    • 2010
  • 나노하이브리드 방법으로 제조된 변성 폴리이드계 나노하이브리드 절연코팅의 표면 내열특성을 비교 분석하였다. 최근 절연코팅의 사용환경이 열적내구성을 높게 요구하는 경향이 크다. 따라서 이러한 환경에 맞는 절연성과 열적내구성을 구현하기 위해서는 열적내구성이 우수한 세라믹 일자를 수지에 분산시켜 그 성능을 개선할 필요가 있다. 본 논문에서는 나노 하이브리드 방법으로 제조된 변성 폴리이드계 나노하이브리드 절연코팅의 표면 내열특성을 비교 분석하였다.

  • PDF

인버터 서지와 온도 스트레스 하에서 Magnet Wire 절연 수명평가 (Insulation Life Estimation for Magnet Wire Under Inverter Surge and Temperature Stress)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제29권10호
    • /
    • pp.641-646
    • /
    • 2016
  • Coil specimen was prepared by coating a copper wire with two varnish thin layers: the first was polyamideimide (PAI)/nanosilica (5 wt%) varnish and the second was anti-corona PAI/nanosilica (15 wt%) varnish. Insulation breakdown voltage was investigated under inverter surge condition at $20^{\circ}C$, $70^{\circ}C$, $100^{\circ}C$, $150^{\circ}C$, $200^{\circ}C$, $250^{\circ}C$, respectively. The insulation lifetime of the two layered coil was tens of times longer than that of original PAI coil. And the insulation lifetime decreased with increasing ambient temperature because there was weak binding strength between copper and varnish layer.

부스닥트용 에폭시 분체도료의 열 및 수중열화에 대한 전기적 특성 (Electrical Properties about Thermal and Water Degradation of Epoxy Powder for Bus Duct)

  • 김현희;김상현
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.17-22
    • /
    • 2009
  • 에폭시 분체도료는 부스닥트, 및 전기기기에 절연재료로 광범위하게 사용되어 진다. 특히 Coating 절연 방식의 경우 전류에 의한 줄 열로 인해 전기화재 및 폭발의 점화 원인이 된다. 본 연구는 에폭시분체도료의 열화특성에 대해 절연파괴, 아크방전, 수명특성(V-t)을 중심으로 비교검토하고 이에 대한 기초데이터 확보 및 전기화재 원인인 절연특성에 대해 연구 하였다. 온도변화에 따른 절연특성은 시편 KS가 유리전이온도(Tg) 이전까지 $8{\sim}10%$ 정도의 감소로 안정적이었다. V-t 및 아크방전특성의 경우, 열화시편에서도 안정적 특성을 유지하였다. 열화에 의한 전기적특성의 경우 시편KS가 우수한 성능을 가지고 있다.

열적 열화 온도 변화에 따른 PAI 에나멜 각형코일의 절연 파괴 주파수 특성 (Insulation Breakdown Frequency Properties of PAI Enamelled Rectangular Coils According to Thermal Deterioration Temperature Variation)

  • 박재준
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.829-834
    • /
    • 2016
  • Coil specimens were prepared by continuous coating on a copper wire with flexible PAI (polyamideimide) and PAI/nanosilica (5 wt%) varnish and thermally aged at 150, 200 and $250^{\circ}C$ for 5, 10 and 15 days, respectively. AC insulation breakdown voltage was investigated under inverter surge condition at 60 Hz and 1,000 Hz and insulation breakdown voltage decreased with increasing aging temperature and aging time at each 60 and 1,000 Hz.