• 제목/요약/키워드: Electrical fire sign

검색결과 6건 처리시간 0.017초

화재징후 조기표출과 복합검사를 위한 표출재 설계, 제작 및 성능 평가 (Design, Fabrication, and Performance Evaluation of Showing Material for Early Expression of Fire Signs and Combined Inspection)

  • 신동철;고형호
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.187-193
    • /
    • 2023
  • Previous research has explored early expression of fire signs before the burning of insulation. To achieve this, typically, automatic inspections are used to detect gas emitted from odor capsules at electrical connection points; additionally, early fire signs can be expressed using visual inspection of changes in the appearance of temperature caps. However, early detection of electrical fire is often difficult because only specific inspections, which are not complex, are performed. Therefore, in this paper, we present complex inspection techniques, such as visual inspection, odor inspection, and automatic inspection, and propose a showing material of fire signs that can solve conventional problems. In addition, this study examines the conditions under which the candidate material for the showing material is designed, the composition of the candidate material selected based on the designed conditions, the manufacturing means used to produce the showing material considering the temperature for early expression of fire signs, and the performance of the produced showing material. Furthermore, we analyze various effects that can occur through the proposed display material.

전기화재 조사를 위한 분류체계 개발 (Development of a Classification System for an Electrical Fire Investigation)

  • 이종호;김두현
    • 한국안전학회지
    • /
    • 제20권3호
    • /
    • pp.53-57
    • /
    • 2005
  • This paper presents development of a classification system for an electrical fire investigation. In order to reduce an electrical fires and establish detailed prevention plans, the collection of an electrical fire causes and base data are very important. Based on this data, a new classification system for an electrical fire investigation was developed and the direction to the classification system was suggested by fundamental analysis. All of the collected information is analyzed by bottom-up method. Criteria items which based on base data were categorized to classify items. The classification of items were found out as follows : basic condition fire scene condition, fire sign, fire cause. Particularly, the fire cause category is classified. A new developed classification system for an electrical fire investigation will be used to analyse electrical fires easily and efficiently.

고효율 LED를 이용한 유도등의 원격제어에 관한 연구 (A Study on the Remote Control for Exit Sign Using High Efficiency LED)

  • 백동현;홍석표
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.1-7
    • /
    • 2002
  • 유도등은 일정한 조도를 가지고 상용전원에 의하여 항상 점등되어 있어야 함으로 전력소비 및 광원 교체등 경제적 손실과 관리상의 문제가 있게 된다. 본 논문은 이제까지 광원으로 사용하고 있던 형광등이나 백열전구 대신에 소비전력이 적은 고효율 발광다이오드를 사용하여 전력소비의 절감과, 점검시의 문제점을 개선하기 위해 원격제어가 가능한 새로운 유도등회로를 제안하고 실험한 것이다. 그 결과 원격제어 스위치에 의한 유도등 점검을 제어각의 범위에서 쉽게 제어할 수 있었으며 반응시간은 600〔$\mu$s〕로 매우 빠르게 동작하였다. 또한 출력 상승시간(Rise time)과 하강고시간(Fall time)은 최대 200〔ns〕로 예민하게 반응하였다. 광원으로 고효율 발광다이오드를 사용함으로 광원을 교체해야 하는등의 문제를 제거하였으며 전력소비를 감소시킬 수 있음을 확인하였다.

전기화재 분야에서 다목적으로 시험장치의 활용범위를 증가시키기 위한 시험장치의 설계 및 구현 (Design and Implementation of a Multi-purpose Test Equipment with a Large Utilization Range for use in Electric Fire)

  • 신동철;고형호
    • 센서학회지
    • /
    • 제32권3호
    • /
    • pp.180-186
    • /
    • 2023
  • Test devices can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the launch of combined products. However, the scope of use of test devices is limited because they perform only a single role or could only serve a particular purpose in the past. Therefore, studies on test devices that can perform various functions, such as research on detection targets, sensors that detect detection targets, combined products containing sensors, and certification for the release of combined products are necessary. Accordingly, this study proposes a test device that can increase the scope of use in the technical field of electric fires. In addition, we examine various outcomes of the proposed test device.

에어컨 배수펌프 설치 실태 및 개선방안 분석 - 창원시를 중심으로 (Analysis on Installation Conditions Survey and Improvement of Drain Pump in Air-Conditioner : Focusing on Changwon City)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제26권8호
    • /
    • pp.102-106
    • /
    • 2012
  • This paper was carried out to survey fire hazard and improvement at the drain pump in air-conditioners. Based on the results of analysis, the proposal of electrical accidents prevention and a construction improvement are as follows. A power connection of the drain pump has two types, an electrical outlet type and direct connection type at control board of air-conditioner. The electrical outlet types need a bulletin sign or education as malfunction of the drain pump include an additional accidents, current leakage and overflowing with water on the floor from breaker trip by exterior cause and breaker off by mistake of worker. On the other hand, the direct connection types prevent a power interruption as exterior cause, but it has some trouble, cut of ground cable and without protection device. Usually it doesn't work by electrician when air-conditioner and the drain pump power work. Therefore an education or countermeasures are recommended for not electrician. Generally malfunction of the drain pump causes accumulated materials into the tank. Even though the accumulated materials lead to an overheating and burning as failure of detector occur an idling, periodic inspection of the air-conditioner filter and the drain pump tank prevent the trouble.

Environment Adaptive Emergency Evacuation Route GUIDE through Digital Signage Systems

  • Lee, Dongwoo;Kim, Daehyun;Lee, Junghoon;Lee, Seungyoun;Hwang, Hyunsuk;Mariappan, Vinayagam;Lee, Minwoo;Cha, Jaesang
    • International Journal of Advanced Culture Technology
    • /
    • 제5권1호
    • /
    • pp.90-97
    • /
    • 2017
  • Nowadays, the most of commercial buildings are build-out with complex architecture and decorated with more complicated interiors of buildings so establishing intelligible escape routes becomes an important case of fire or other emergency in a limited time. The commercial buildings are already equipped with multiple exit signs and these exit signs may create confusion and leads the people into different directions under emergency. This can jeopardize the emergency situation into a chaotic state, especially in a complex layout buildings. There are many research focused on implementing different approached to improve the exit sign system with better visual navigating effects, such as the use of laser beams, the combination of audio and video cues, etc. However the digital signage system based emergency exit sign management is one of the best solution to guide people under emergency situations to escape. This research paper, propose an intelligent evacuation route GUIDE that uses the combination centralized Wireless Sensor Networks (WSN) and digital signage for people safety and avoids dangers from emergency conditions. This proposed system applies WSN to detect the environment condition in the building and uses an evacuation algorithm to estimate the safe route to escape using the sensor information and then activates the signage system to display the safe evacuation route instruction GUIDE according to the location the signage system is installed. This paper presented the prototype of the proposed signage system and execution time to find the route with future research directions. The proposed system provides a natural intelligent evacuation route interface for self or remote operation in facility management to efficiently GUIDE people to the safe exit under emergency conditions.