Study on Fire Simulation in College Dormitories Based on Pyrosim

  • Zechen Zhang;Hasung Kong
    • International journal of advanced smart convergence
    • /
    • v.13 no.3
    • /
    • pp.321-327
    • /
    • 2024
  • In recent years, the frequency of fires in college dormitories has been increasing, primarily due to outdated electrical wiring and improper use of electrical appliances. Given the high population density in such buildings, fires can cause significant damage to life and property. To better understand the dynamics of dormitory fires, this study uses Pyrosim fire simulation software to model fire scenarios in a six-story male dormitory. The study focuses on analyzing key factors such as heat release rates, smoke spread, temperature changes, and carbon monoxide concentrations during a fire. Simulation results indicate that smoke spreads rapidly after a fire breaks out, significantly reducing visibility and hindering evacuation efforts. Simultaneously, temperatures near the fire source rise quickly, exceeding safe levels, and carbon monoxide concentrations reach dangerous thresholds in a short time, greatly increasing the risk of poisoning. Based on these findings, the study proposes several recommendations to improve fire prevention in dormitories, including installing smoke barriers, improving evacuation routes, adding mechanical smoke extraction systems, and enhancing students' fire safety awareness and skills through regular training. These measures are crucial for reducing fire risks and enhancing fire safety in college dormitories.

A Study on Economic Evaluations of ESS Load Test Device for Field Load Test in Fire-fighting Emergency Generator Systems (소방용 비상발전기의 현장부하시험을 위한 ESS 부하시험장치의 경제성평가에 관한 연구)

  • Choi, Seung-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.380-386
    • /
    • 2020
  • The ESS load test device (ELTD) can store and exchange electrical energy during the load test of an emergency generator. On the other hand, it is difficult to commercialize ELTDs based on Li-ion batteries because of the high initial cost, which is higher than a load bank test. If the trade of electrical energy stored in ELTD during the test of an emergency generator is considered, it may be possible to commercialize the ELTD. Therefore, this paper proposes an economic model of ELTD composed of the costs and benefits by considering electrical energy trade to perform accurately economic evaluations of an ELTD. From the simulation results of the economic evaluations of an ELTD and the load bank method, it was found that the commercialization of ELTD is possible when the trade in electrical energy in ELTDs is considered.

A Study on Internet Emergency Alert Distribution System Adaptive to the Receiver Characteristics (인터넷 기반의 수신자 맞춤형 재난경보 전달시스템 연구)

  • Ahn, Soyoung;Jeon, Inchan;Kim, Jihee;Lee, Yong Tae;Choi, Seong Jong
    • Journal of Broadcast Engineering
    • /
    • v.20 no.4
    • /
    • pp.598-605
    • /
    • 2015
  • Effective alerts will drastically mitigate the disaster impacts. One way to enhance the effectiveness is to prepare multiple alert distribution channels. In this paper, we propose a new emergency alert distribution system that will solve the weaknesses of the current distribution systems, such as Cell Broadcasting System and T-DMB Automatic Emergency Alert Service. The weaknesses are: the limitation of message length, small portions of terminals that can receive and display the alert signal, and one-way communication service. To solve these problems, we propose an emergency alert distribution system over the Internet with RSS (Rich Site Summary) format. The system also has the capability of adaptive alert filtering according to the receiver characteristics. We analyzed the characteristics of RSS as an alerting format, and draw functional requirements satisfying use case scenarios. We designed the system only with major requirements and verified it on our test bed. Sending richer message contents through various receiving terminals, the system will achieve more effective emergency alert service.

A Study on Application of Electrical Resistivity Survey to Detect the Leakage of Embankment with Weak Zone (취약대가 존재하는 제방의 누수 탐지를 위한 전기비저항 탐사의 적용성 연구)

  • Park, Samgyu;Kim, Jaehong
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.4
    • /
    • pp.5-13
    • /
    • 2013
  • The water leakage of reservoir embankment usually occurs around channelling pipes, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain and the rainy season in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disaster prevention and embankment maintenance. The water leakage in dams and levees where the channelling pipes are working as weak zone was analyzed by using both numerical simulation and experimental method in this study. To detect the water leakage, an electrical resistivity survey was used and investigated for its' usability. The numerical results show the size and location of weak zone increases the importance of selection of electrode spacing. The leakage experiments of model embankment present the best result is obtained under the conditions of electrode spacing of 0.3m and dipole-dipole array. By studying the water leakage in dams and levees, the electrical resistivity survey is observed it is a very useful method to predict the leakage.

Requirement Analysis of Korean Public Alert Service using News Data (뉴스 데이터를 활용한 재난문자 요구사항 분석)

  • Lee, Hyunji;Byun, Yoonkwan;Chang, Sekchin;Choi, Seong Jong
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.994-1003
    • /
    • 2020
  • In this paper, we investigated the current issues on the KPAS(Korean Public Alert Service) by News analysis. News articles, from May 15, 2005 to April 30, 2020, were collected with the key word of 'KPAS' through the News Big-Data System provided by the Korea Press Foundation. The results of the content analysis are as follows. First, the issues on alert presentation were categorized by alarm sound, message content, alert level, transmission frequency, delay, reception range, time of alert, and language. Issues on inability to receive KPAS messages were categorized into authority, mobile, sending standard, mobile communication infra, etc. For the last two to three years, news on the inability issues had decreased, while news on the presentation issues had increased. This tells us that the public demand for improvement in the KPAS lies in the presentation issues. The demand for societal resolutions to the presentation issues especially on message content, transmission frequency, and reception range has soared.

A Study on Standardization of UPS (Uninterruptible Power Supply) for Traffic Signal Controller (교통신호제어기용 무정전전원장치 용량기준 연구)

  • Ko, Kwang-Yong;Lee, Choul-Ki;Kim, Min-Sung;Heo, Nak-Won;Jeong, Jun-Ha
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.11 no.5
    • /
    • pp.1-6
    • /
    • 2012
  • Unlike the past, modern urban intersections have dramatic growth in size and utilizations. As a result, continual traffic signal control is essential. Hence the individual or regional electrical blackout may bring about uncontrollable traffic congestion. Late summer of 2011 a regional blackout brought about traffic nightmare not including time and revenue loss associated with this disaster. Due to this disaster our national police agency and other government agencies are in process of introducing an UPS (uninterruptible power supply) system into essential intersections. This study estimates the power consumption necessary to sustain at least 2 continuous hours for a standard four-legged intersection. Prototype was studied using these standards. The field experiment of prototype showed positive results and was able to meet standard guidelines set forth. Prototype tested was able to meet standards in medium to large capacity of traffic size.

Development of Hybrid Power Storage System for Urban Railway with UPS Function for Emergency Power Generation (비상발전용 UPS 기능을 갖춘 도시철도용 복합형 전력저장시스템 개발)

  • Hong, Kyungjin
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.19 no.6
    • /
    • pp.191-196
    • /
    • 2019
  • In the case of urban railway facilities, the power supply should be maintained for the safe movement of passengers in communication facilities, disaster prevention facilities and boarding area security because of the confusion when power supply is cut off due to the nature of public transportation. In addition, considering that the number of trains is running on the urban railway line, it is necessary to operate at least 30 minutes for the bus stop and at least 1 hour for the communication and disaster prevention facilities. Therefore, it is essential to supply emergency power source to maintain stable operation of induction lamp and smoke exhaust system because main power is cut off in order to prevent further spread due to fire in case of the history of urban railway section or vehicle fires. Recently, UPS(Uninterruptible Power Supply) function to prevent power outage in emergency, emergency power generation combined with ESS function which saves electricity at nighttime price time, A hybrid power storage system with a UPS function.

Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors (화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발)

  • Park, Mi Yun;Park, Jong Bok;Park, Jae Hak
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.61-70
    • /
    • 2012
  • The range of special management target facilities is seperated by the building sector and the field of civil engineering. In the present study, the risk analysis was performed, related to fire occurred for the last five years, in the field of residential and non-residential facilities in buildings. Most of fire incidents occurred in residential and non-residential facilities was the cause of the electrical, and the resulting casualties were also very high. Therefore, based on the results, the risk evaluation index was developed, identifying the causes of fire occur and doing the fire vulnerability analysis for each facility. The result of this study can be utilized safety management to these facilities for the future, especially, inducing a more specialized and intensive safety management.

An Investigation of Quantitative Risk Assessment Methods for the Thermal Failure in Targets using Fire Modeling (화재모델링을 이용한 목표 대상물의 열적 손상에 대한 정량적 위험성 평가방법의 고찰)

  • Yang, Ho-Dong;Han, Ho-Sik;Hwang, Cheol-Hong;Kim, Sung-Chan
    • Fire Science and Engineering
    • /
    • v.30 no.5
    • /
    • pp.116-123
    • /
    • 2016
  • The quantitative risk assessment methods for thermal failure in targets were studied using fire modeling. To this end, Fire Dynamics Simulator (FDS), as a representative fire model, was used and the probabilities related to thermal damage to an electrical cable were evaluated according to the change in fire area inside a specific compartment. 'The maximum probability of exceeding the damage thresholds' adopted in a conservative point of view and 'the probability of failure' including the time to damage were compared. The probability of failure suggested in the present study could evaluate the quantitative fire risk more realistically, compared to the maximum probability of exceeding the damage thresholds with the assumption that thermal damage occurred the instant the target reached its minimum failure criteria in terms of the surface temperature and heat flux.

A Study on Safety against Secondary Disaster due to Submergence of Electrical Equipments in Underground Premises using Fuzzy contol and Surveillance system (영상 감시와 퍼지 제어를 이용한 지하구내 전기설비의 침수에 의한 2차 재해에 대한 안전성 연구)

  • Gwon, Dong-Min;Gang, Min-Hui;Jo, Seong-Won;Kim, Jun-Beom;Jeong, Jong-Uk;Jeong, Jin-Su
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.11a
    • /
    • pp.378-381
    • /
    • 2007
  • 지상의 침수와 지하공간의 침수는 많은 부분에서 발생 및 진행 메커니즘이 다르므로, 침수시 요구되는 대응방안 또한 많은 차이를 나타내고 있다. 일반적으로 지하구내의 침수 피해는 지상에 비해 피해 규모가 막대할 뿐만 아니라 복구에도 많은 어려움이 있다. 생명과 재산의 피해를 최소화할 수 있는 적절한 대책이 필요하다. 본 논문에서는 영상처리와 퍼지 제어를 적용해서 지하구내 침수 상황을 감시 ${\cdot}$ 통제하고 안전성을 평가하는 알고리즘과 시스템을 제안한다.

  • PDF