• Title/Summary/Keyword: Electrical current

Search Result 16,465, Processing Time 0.043 seconds

A Study on the Effect of Superconducting Fault Current Limiter in Power System with Separated Bus and Superconducting Fault Current Limiter (모선 분리 운영중인 전력계통에 초전도 한류기 적용 효과 및 영향에 관한 연구)

  • Kim, Myong-Hyon;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.12
    • /
    • pp.74-79
    • /
    • 2012
  • Currently, separated buses were increased to limit a fault currents in power transmission system. However, separated buses caused bad influences such as a decrease of reliability and stability. Superconducting fault current limiter (SFCL) was proposed to limit a fault current lately and that has many merits beside any other solutions. Therefore, we proposed the install of Superconducting fault current limiter (SFCL) in power transmission system with separated bus. And our proposal was verified by reliability of power system.

A Study on the Electrical Properties and Fabrication of Electret Element by Functional Ultra Thin Films -Electrical conduction in LB Ultra Thin Films of TCNQ- (기능성 초박막을 이용한 Electret 소자의 제작과 전기물성에 관한 연구-LB초박막 TCNQ의 전기전도 특성-)

  • 권영수;박만철;이원재;홍언식;강도열
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.40 no.5
    • /
    • pp.489-495
    • /
    • 1991
  • In this paper, we study the electrical conduction mechanism in Langmuir-Blodgett(LB) ultra thin films for which the LB device has a metal/LB films(TCNQ)/metal sandwich structure. Our experiments show that the current at the LB device does not depend on the temperature at below 0 C. This phenomena confirm that the electrical conduction current is a tunnel current inherent to ultra thin films. However, the current depends upon the temperature near the room temperature. This phenomena indicates the electeical conduction current is a Schottky current inherent to ultra thin films.

  • PDF

Analysis of High Current Copper Bus Bar Temperature in Smelting Plants (제련설비용 대전류 동 Bus Bar의 온도해석)

  • Kwak, Byung-Kil;Kim, Changl-Hwan;Choi, Byung-Ju;Kim, Kyu-Ho;Rhee, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.11
    • /
    • pp.26-32
    • /
    • 2014
  • In electrolysis smelting plants that using high DC current, the bus bar is most important facility for delivering the high current. The copper made bus bar is widely used for various advantages as good electrical and thermal conductivity, resonable malleability, ductility, and not rust easily. However, when high current in copper bus bar, temperature rises and maximum allowable current capacity is restricted by temperature of bus bar. In this paper, we investigated temperature variation of copper bus bar by putting cooling water channel imposed to bus bar construction. For the validity, various simulations were carried out.

Analysis on the Operation Characteristics and Protection Coordination between the Current Ratio Differential Relay for Line Protection and the Trigger-type SFCL in the Power Transmission System (송전급 초전도한류기의 적용에 따른 선로보호용 비율전류차동계전기의 동작특성 및 보호협조 분석)

  • Cho, Yong-Sun;Kim, Jin-Seok;Lim, Sung-Hun;Kim, Jae-Chul
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.7
    • /
    • pp.925-930
    • /
    • 2013
  • The fault current of the power transmission system is greater than that of the power distribution system. Therefore, the introduction of superconducting fault current limiter (SFCL) is more needed to reduce the increased fault current. The trigger-type SFCL consists of the high-temperature superconducting element (HTSC), the current limiting reactor (CLR) and the circuit breaker (CB). The trigger-type SFCL can be used to supplement the disadvantages of the resistive-type SFCL. The operation characteristics of the current ratio differential relay which is usually applied to the protection device of the power transmission system are expected to be affected under fault conditions and the applicability of the trigger-type SFCL. In this paper, we analyzed the operating characteristics, by the fault conditions, between the current ratio differential relay for line protection and the trigger-type SFCL in the power transmission system through the PSCAD/EMTDC simulation.

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.

A Study on the Design of Built-in Current Sensor for High-Speed Iddq Testing (고속 전류 테스팅 구현을 위한 내장형 CMOS 전류 감지기 회로의 설계에 관한 연구)

  • Kim, Hoo-Sung;Park, Sang-Won;Hong, Seung-Woo;Sung, Man-Young
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1254-1257
    • /
    • 2004
  • This paper presents a built-in current sensor(BICS) that can detect defects in CMOS integrated circuits through current testing technique - Iddq test. Current test has recently been known to a complementary testing method because traditional voltage test cannot cover all kinds of bridging defects. So BICS is widely used for current testing. but there are some critical issues - a performance degradation, low speed test, area overhead, etc. The proposed BICS has a two operating mode- normal mode and test mode. Those methods minimize the performance degradation in normal mode. We also used a current-mode differential amplifier that has a input as a current, so we can realize higher speed current testing. Furthermore, only using 10 MOSFETS and 3 inverters, area overhead can be reduced by 6.9%. The circuit is verified by HSPICE simulation with 0.25 urn CMOS process parameter.

  • PDF

Analysis on the quenching characteristics of a superconducting fault current limiter with 2 by 3 matrixes ($2{\times}3$행렬구조를 갖는 초전도 한류기의 퀜치특성 분석)

  • Cho, Yong-Sun;Park, Hyoung-Min;Lee, Ju-Hyoung;Jung, Byung-Ik;Choi, Hyo-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2210-2211
    • /
    • 2008
  • In this paper, we investigated the quenching characteristics of a superconducting fault current limiter (SFCL) with connection of $2{\times}3$ matrixes. This SFCL consists of the trigger part to apply magnetic field and the current-limiting part to limit the fault current. When the fault occurs, the magnetic field generated in the reactor connected in parallel was applied to the two superconducting units of the current-limiting part to reduce of inhomogeneous critical current behavior between the superconducting units. The quenching behavior of a superconducting unit in the trigger part was affected by the increase of turn numbers. This is because of the difference of current distribution between the inductance of the reactors and the resistance generated in the superconducting units in trigger part. We confirmed that the voltage differences between two superconducting units of the current-limiting part were decreased. This is because of the improvement of inhomogeneous critical current behavior between the superconducting units according to the increase of external magnetic field.

  • PDF

The Leakage Current Analysis of ZnO Arrester Using Leakage Current Dete (피뢰기 누설전류 분석장치를 이용한 ZnO 피뢰기의 누설전류 변화 분석)

  • Kim, Young-Chun;Moon, Sun-Ho;Oh, Jung-Hwan;Kim, Jae-Chul;Lee, Young-Gil
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.1082-1084
    • /
    • 1998
  • In this paper, we developed a diagnosis device for ZnO arrester to detect on-line leakage current and acquire data from the power distribution system. The arrester is important power equipment used in power transmission and distribution systems to protect the generator and the main transformer from surge and overvoltage. First of all we developed a diagnosis device for ZnO arrester leakage current. And then we detect the total leakage current by the developed device without disconnecting the arrester ground wire and analysis the 3rd order harmonic by Fast Fourier Transform(FFT) to diagnose the ZnO arrester deterioration. With measuring the total current and the resistive current of power distribution system in operation, we analysis the trend of resistive current component in the total leakage current. We expect the result will be promote the method to protect electrical utility and customer from accident.

  • PDF

Film Thickness Dependences of Ac High Field Dissipation Current Waveform for LDPE (저밀도 폴리에틸렌에 있어서 전압 파형의 두께 의존성)

  • Yun, Ju-Ho;Choi, Yong-Sung;Moon, Jong-Dae;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.349-350
    • /
    • 2007
  • Polyethylene is widely used as the insulator for power cable. To investigate the conduction mechanism for power cable insulation under ac high field, it is very important to acquire the dissipation current under actual running field. Recently, we have developed the unique system, which make possible to observe the nonlinear dissipation current waveform. In this system, to observe the nonlinear properties with high accuracy, capacitive current component is canceled by using inverse capacitive current signal instead of using the bridge circuit for canceling it. As the results of these estimations, it was found that the dissipation current will depend on not only the instantaneous value of electric field but also the time differential of applied electric field due to taking a balance between applied field and internal field. Furthermore, two large peaks of dissipation current for each half cycle were observed under certain condition. In this paper, to clarify the reason why it shows two peaks for each half cycle, the film thickness dependences of dissipation current waveforms were observed by using the three different thickness LDPE films.

  • PDF

Current Sharing of Parallel Connected Bi-2223 High-$T_{c}$ Superconducting paths

  • Bae, Duck-Kweon;Hyoungku Kang;Ahn, Min-Cheol;Kim, Yeong-Sik;Yoon, Kyung-Yong;Yoon, Yong-Soo;Bae, Jun-Han;Ko, Tae-Kuk
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.2
    • /
    • pp.20-24
    • /
    • 2004
  • Bi-2223 wire, the first-generation high temperature superconducting (HTS) wire, was successfully commercialized and various electrical machinery and equipment are actively being developed in many countries. Because its critical current is too small to realize the lossless conducting part of electric power system with a HTS wire, multi-HTS paths are used to enlarge the critical current of HTS system. Though the resistance generated in HTS wire by transport current is very small, the difference of it in multi-path is the additional reason which causes the non-uniform current sharing in multi-HTS path except the well known reason, the difference of inductance between each path. In this paper, experimental research on current sharing of multi-strand and multi-stacked HTS wire was implemented. The whole critical current of multi-HTS paths is not equal to sum of critical current of each path because of non-uniform current sharing occurred in this paths. It was verified experimentally that Bi-2223 wires have different resistance generated by same transport current even if they was manufactured in same progress of work. Current sharing phenomenon was affected by difference of resistance and self and mutual inductance.