Characteristics of LSC coated Metallic Interconnect for Solid Oxide Fuel Cell (LSC가 코팅된 고체산화물 연료전지용 금속연결재의 특성 연구)

  • Pyo, Seong-Soo;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.48 no.2
    • /
    • pp.172-177
    • /
    • 2010
  • This study reports the high-temperature oxidation kinetics, ASR(area specific resistance), and interfacial microstructure of metallic interconnects coated with conductive oxides in oxidation atmosphere at $800^{\circ}C$, The conductive material LSC($La_{0.8}Sr_{0.2}CoO_3$, prepared by Solid State Reaction) was coated on the Crofer22APU. The contact behavior of coating layer/metal substrate was increased by sandblast. The electrical conductivity of the LSC coated Crpfer22APU was measured by a DC two probe four wire method for 4000hr, in air at $800^{\circ}C$. Microstructure and composition of the coated layer interface were investigated by SEM/EDS. These results show that a coated LSC layer prevents the formation and growth of oxide scale such as $Cr_2O_3$ and enhances the long-term stability and electrical performance of metallic interconnects for SOFCs.

FMECA Procedure for Failure Analysis of Train High-Speed Circuit Breaker (전동차 고속차단기 고장 분석을 위한 FMECA 기법)

  • Kim, Sung-Ryeol;Moon, Yong-Sun;Choi, Kyu-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.5
    • /
    • pp.3370-3377
    • /
    • 2015
  • FMECA(Failure Mode, Effects and Criticality Analysis) techniques to make quantitative evaluation of failure effects severity and criticality have been applied to systematic failure analysis for reliability improvement of train which should provide regular service and secure high level of safety as a mass transportation system. These FMECA techniques do not fully reflect the inherent train operation and maintenance circumstances because they are based on the FMECA standards devised for other industries such as automobile industry and FMECA standard dedicated to train industry has not been established yet. This paper analyzes FMECA standards for various industries, and suggests a FMECA technique dedicated to train industry which makes failure effect analysis and criticality analysis step by step and makes criticality analysis placing emphasis on the severity of the failure effect. The proposed technique is applied to FMECA of high-speed current breaker which is a core safety device of train using field failure data for 15 years of train maintenance. The FMECA results show that breakage of arc chute has the highest risk with 3rd severity class and 5th criticality class among all the components of high-speed circuit breaker. Damage and poor contact of electronic valve, and cylinder breakage with 3rd severity class and 4th criticality class are followed by. These results can be applied to improvement of design and maintenance process for high-speed circuit breaker of train.

Clinical and Statistical Analysis with Age in Cases of Pediatric Burn Patients (소아 화상 환자 2,795례에 대한 연령별 임상 통계학적 분석)

  • Cho, Ki-Hyun;Jang, Young-Chul;Lee, Jong-Wook;Koh, Jang-Hyu;Seo, Dong-Kook;Choi, Jai-Ku
    • Archives of Plastic Surgery
    • /
    • v.38 no.4
    • /
    • pp.445-450
    • /
    • 2011
  • Purpose: The objective of this study is to analyze the epidemiological characteristics of pediatric burn patients and to determine the targets for a pediatric burn prevention program. Methods: A retrospective review of all medical records of acute pediatric burn patients (age < 15 years old) admitted to our hospital between January 2005 and December 2009 was performed. Results: 1472 males and 1323 females were investigated, with a male to female ratio of 1.11 : 1. The greatest number of burn patients were those with an age of 1~2 years (1,463, 52.3%). Scalding burn was the most common cause of injury, which accounted for 2183 (78.1%) patients, followed by contact burns (10.5%), flame burn (4.9%), steam burn (3.6%). Especially steam burn was the second cause of injury in the age under 1 year, while flame burn was the second cause of injury in the age over 7 years. During recent 5 years, incidence of flame burn, steam burn, electrical burn gradually decreased. Variation of seasonal incidence is minimal and most of the patients (2,716 cases, 97.2%) had burns less than 20% TBSA (Total body surface area). The median hospital stay was 18.79 days, and the rate of operation was 28.6% with a high rate in electrical burn (76.2%), flame burn (50.0%), steam burn (46.1%). 6 patients died in this series, which yielded a mortality rate of 0.2%. Conclusion: Prevention efforts should reflect recent study results. Focused prevention program and campaign to make people aware of risk factors and their avoidance is required to reduce the number of burn accidents in children.

Development of Coupler for Live Cable Fault Detection Based on Reflectometry (반사파 계측법 기반의 활선 케이블 고장 검출을 위한 커플러의 개발)

  • Jeon, Jeong-Chay;Oh, Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.401-406
    • /
    • 2016
  • When measuring live cable faults and their location based on reflectometry, a coupler is placed between the cable and the test system. This coupler prevents damage to the test circuits by indirectly measuring the live voltage of the cable using reflectometry. It also provides a coupling path that allows the transmission and receive signal to pass into the cable. In this study, we design and construct a contact coupler to locate faults in both dead and live cables using reflectometry. The proposed coupler is of the inductive coupling type and is constructed after the calculation of the signal transmission loss by simulation. The performance of the developed coupler is tested by measuring the transmission loss and frequency flatness. The results showed that the transmission signal loss is less than -1.98dB in the frequency bandwidth above 1 Mhz. The reflectometry system was designed based on sequence time domain reflectometry (STDR) and spread spectrum time domain reflectometry (SSTDR) in order to apply it to the detection of faults and their location in live cables and tests on live cables were performed. The test results showed that the proposed coupler can be used in a reflectometry system for live cable fault detection.

Self-Sensing and Interfacial Evaluation of Ni Nanowire/Polymer Composites Using Electro-Macromechanical Technique (전기적 미세역학적 시험법을 이용한 Ni nanowire강화 고분자 복합재료의 자체 감지능 및 계면 물성평가)

  • Kim, Sung-Ju;Yoon, Dong-Jin;Hansen George;DeVries K. Lawrence;Park, Joung-Man
    • Composites Research
    • /
    • v.19 no.5
    • /
    • pp.20-27
    • /
    • 2006
  • Self-sensing and interfacial evaluation of Ni nanowire/polymer composites were investigated using electro-macromechanical technique, which can be used fur a feasible sensing measurement on tensile and compressive loading/consequent unloading, temperature, and humidity. Mechanical properties of Ni nanowire with different aspect ratio and adding contents in either epoxy or silicone composites were measured indirectly using electro-pullout test under uniform and non-uniform cyclic loadings. Comparing apparent modulus with the conventional mechanical tensile modulus of Ni nanowire/epoxy composites, the trends were consistent with each other. Ni nanowire/epoxy composites showed the sensing response on humidity and temperature. Self-sensing on applied tensile and compressive loading/unloading was also responded for Ni nanowire/silicone composites via electrical contact resistivity showing the opposite trend between tension and compression. It can be due to the different electrically-interconnecting mechanisms of dispersed Ni nanowires embedded in silicone matrix.

A Study on the Optimization of α-Al2O3 Powder Manufacturing for the Application of Separators for Lithium-Ion Secondary Batteries (리튬이차전지용 분리막 적용을 위한 α-알루미나 분말 제조 최적화 연구)

  • Dong-Myeong Moon;Da-Eun Hyun;Ji-Hui Oh;Jwa-Bin Jeon;Yong-Nam Kim;Kyoung-Hoon Jeong;Jong-Kun Lee;Sang-Mo Koo;Dong-Won Lee;Jong-Min Oh
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.36 no.6
    • /
    • pp.638-646
    • /
    • 2023
  • Recently, active research has been conducted to enhance the power characteristics and thermal stability of lithium-ion batteries (LiBs) by modifying separators using a ceramic coating method. However, since the thermal properties and surface features of the separator vary depending on the characteristics of the ceramic powders applied to the separator, it is crucial to manufacture ceramic powders optimized for the separator's performance. In this study, we evaluated the characteristics of three types of α-alumina (A-1, A-2, and A-3) produced with varying dispersant contents and milling times, in addition to commercial α-alumina (AES-11). Subsequently, the optimized powders (A-3) were coated onto the separator using an aqueous binder for comparison with the characteristics of an AES-11 coated separator and an uncoated PE separator. The A-3 coated separator improved electrolyte wettability with a low contact angle (44.69°) and increased puncture strength (538 gf). Furthermore, it exhibited excellent thermal stability, with a shrinkage value of 5.64% when exposed to 140℃ for 1 hour, compared to the AES11 coated separator (6.09%) and the bare PE separator (69.64%).

A Study of Control for 3 Phase BLDC Motor using Control Methodology of DC Motor (직류전동기 제어기법을 적용한 3상 BLDC 모터 제어에 관한 연구)

  • Jin-Man Kim;Taek-Kun Nam
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.6
    • /
    • pp.704-711
    • /
    • 2023
  • This paper discusses the control method of BLDC(Brushless Direct Current) motor that has similar electrical characteristics with DC motor but has improved its lifespan and reliability. The BLDC motor can improve durability and speed stability by using rotor position information to eliminate commutators that require mechanical contact with DC motors. In this study, a controller for a DC motor was designed based on the fact that the current in the windings of a BLDC motor is a square-wave current like the current flowing in the armature of a DC motor. Next, the designed controller was applied to a 3-phase BLDC motor to confirm the effectiveness of the controller. In detail, a single-phase DC motor with electrical parameter values of a three-phase BLDC motor was modeled and a PI controller for motor speed control was designed by applying the root locus method to the derived system. The speed control simulation of the DC motor was performed to confirm the validity of the controller, and the same controller was applied to the speed control of the 3-phase BLDC motor implemented in MATLAB. From the simulation, similar results of the DC motor were obtained in the 3 phase BLDC motor and confirmed the usefulness of the proposed control scheme.

Synthesis of Core@Shell-Structured Silicon@Carbon Nanoparticles by One-Pot Spray Pyrolysis Process and Application as Anode Materials for Lithium-Ion Batteries (단일 분무 열분해 공정을 이용한 코어@쉘 구조의 Si@C 나노 분말 합성 및 리튬 이온 전지 음극소재 적용)

  • Seong Ho Jung;Jae Seob Lee;Jung Sang Cho
    • Clean Technology
    • /
    • v.30 no.3
    • /
    • pp.220-227
    • /
    • 2024
  • As the demand for lithium-ion batteries with high capacity and high energy density has rapidly increased, silicon anodes (theoretical capacity = 3,570 mA h g-1) have garnered attention as potential replacements for conventional graphite anodes (theoretical capacity = 372 mA h g-1). However, silicon anodes suffer from severe volume expansion (~360%) during lithiation, low ionic conductivity (10-14 ~ 10-13 cm2 S-1), and low electrical conductivity (10-2 S cm-1), resulting in poor cycling and rate performance. To address these issues, this study synthesized core@shell-structured silicon@carbon nanoparticles (Si@C NPs) via a one-pot spray pyrolysis process using Pluronic-F127. Pluronic-F127 in the spray solution contributes to the synthesis of nanoparticles by preventing the formation of silicon nanoparticle/dextrin agglomerates and by undergoing pyrolysis simultaneously. Additionally, dextrin derived amorphous carbon was coated on the surface of the silicon nanoparticles to act as an electron transport pathway within the anodes and enhance the electrical contact between the silicon nanoparticles. The Si@C NPs exhibited a discharge capacity of 1,912 mA h g-1 after 50 cycles at 1.0 A g-1 and high rate capabilities (discharge capacity of 1,493 mA h g-1 at 3.0 Ag-1). The silicon@carbon composite nanoparticle synthesis strategy based on the spray pyrolysis process presented in this study is expected to offer a new direction for improving the performance of silicon anode materials.

A Study of Mo Back Electrode for CIGSe2 Thin Film Solar Cell (CIGSe2 박막태양전지용 Mo 하부전극의 물리·전기적 특성 연구)

  • Choi, Seung-Hoon;Park, Joong-Jin;Yun, Jeong-Oh;Hong, Young-Ho;Kim, In-Soo
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.3
    • /
    • pp.142-150
    • /
    • 2012
  • In this Study, Mo back electrode were deposited as the functions of various working pressure, deposition time and plasma per-treatment on sodalime glass (SLG) for application to CIGS thin film solar cell using by DC sputtering method, and were analyzed Mo change to $MoSe_2$ layer through selenization processes. And finally Mo back electrode characteristics were evaluated as application to CIGS device after Al/AZO/ZnO/CdS/CIGS/Mo/SLG fabrication. Mo films fabricated as a function of the working pressure from 1.3 to 4.9mTorr are that physical thickness changed to increase from 1.24 to 1.27 ${\mu}m$ and electrical characteristics of sheet resistance changed to increase from 0.195 to 0.242 ${\Omega}/sq$ as according to the higher working pressure. We could find out that Mo film have more dense in lower working pressure because positive Ar ions have higher energy in lower pressure when ions impact to Mo target, and have dominated (100) columnar structure without working pressure. Also Mo films fabricated as a function of the deposition time are that physical thickness changed to increase from 0.15 to 1.24 ${\mu}m$ and electrical characteristics of sheet resistance changed to decrease from 2.75 to 0.195 ${\Omega}/sq$ as according to the increasing of deposition time. This is reasonable because more thick metal film have better electrical characteristics. We investigated Mo change to $MoSe_2$ layer through selenization processes after Se/Mo/SLG fabrication as a function of the selenization time from 5 to 40 minutes. $MoSe_2$ thickness were changed to increase as according to the increasing of selenization time. We could find out that we have to control $MoSe_2$ thickness to get ohmic contact characteristics as controlling of proper selenization time. And we fabricated and evaluated CIGS thin film solar cell device as Al/AZO/ZnO/CdS/CIGS/Mo/SLG structures depend on Mo thickness 1.2 ${\mu}m$ and 0.6 ${\mu}m$. The efficiency of CIGS device with 0.6 ${\mu}m$ Mo thickness is batter as 9.46% because Na ion of SLG can move to CIGS layer more faster through thin Mo layer. The adhesion characteristics of Mo back electrode on SLG were improved better as plasma pre-treatment on SLG substrate before Mo deposition. And we could expect better efficiency of CIGS thin film solar cell as controlling of Mo thickness and $MoSe_2$ thickness depend on Na effect and selenization time.

Study on the Fire Risk Prediction Assessment due to Deterioration contact of combustible cables in Underground Common Utility Tunnels (지하공동구내 가연성케이블의 열화접촉으로 인한 화재위험성 예측평가)

  • Ko, Jaesun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.135-147
    • /
    • 2015
  • Recent underground common utility tunnels are underground facilities for jointly accommodating more than 2 kinds of air-conditioning and heating facilities, vacuum dust collector, information processing cables as well as electricity, telecommunications, waterworks, city gas, sewerage system required when citizens live their daily lives and facilities responsible for the central function of the country but it is difficult to cope with fire accidents quickly and hard to enter into common utility tunnels to extinguish a fire due to toxic gases and smoke generated when various cables are burnt. Thus, in the event of a fire, not only the nerve center of the country is paralyzed such as significant property damage and loss of communication etc. but citizen inconveniences are caused. Therefore, noticing that most fires break out by a short circuit due to electrical works and degradation contact due to combustible cables as the main causes of fires in domestic and foreign common utility tunnels fire cases that have occurred so far, the purpose of this paper is to scientifically analyze the behavior of a fire by producing the model of actual common utility tunnels and reproducing the fire. A fire experiment was conducted in a state that line type fixed temperature detector, fire door, connection deluge set and ventilation equipment are installed in underground common utility tunnels and transmission power distribution cables are coated with fire proof paints in a certain section and heating pipes are fire proof covered. As a result, in the case of Type II, the maximum temperature was measured as $932^{\circ}C$ and line type fixed temperature detector displayed the fire location exactly in the receiver at a constant temperature. And transmission power distribution cables painted with fire proof paints in a certain section, the case of Type III, were found not to be fire resistant and fire proof covered heating pipes to be fire resistant for about 30 minutes. Also, fire simulation was carried out by entering fire load during a real fire test and as a result, the maximum temperature is $943^{\circ}C$, almost identical with $932^{\circ}C$ during a real fire test. Therefore, it is considered that fire behaviour can be predicted by conducting fire simulation only with common utility tunnels fire load and result values of heat release rate, height of the smoke layer, concentration of O2, CO, CO2 etc. obtained by simulation are determined to be applied as the values during a real fire experiment. In the future, it is expected that more reliable information on domestic underground common utility tunnels fire accidents can be provided and it will contribute to construction and maintenance repair effectively and systematically by analyzing and accumulating experimental data on domestic underground common utility tunnels fire accidents built in this study and fire cases continuously every year and complementing laws and regulations and administration manuals etc.