• 제목/요약/키워드: Electrical connector

검색결과 105건 처리시간 0.02초

하이브리드/전기 자동차용 고전압 커넥터의 전자기 해석 (EM Analysis of High Voltage Connector for Hybrid/Electric Vehicle)

  • 이준상;김종민;남기훈;배현주;성진태;나완수
    • 전기학회논문지
    • /
    • 제60권1호
    • /
    • pp.131-137
    • /
    • 2011
  • This paper analyzes EM(Electromagnetic) characteristic in the high voltage connector for the hybrid electric vehicle. The connector bridges the electrical components and helps transferring electrical power and signal through it. The necessity of the high voltage and current connector development is emphasized because the hybrid electric vehicle recently uses the high voltage and current more than 500V and 80A. So far there has not been international EMC (Electromagnetic Compatibility) standards to limit the RE(Radiation Emission) from the connector for the hybrid electric vehicle. In this paper we analyzed EM characteristic of the 288V, 65A connector to check if the RE from the high voltage connector could be within the RE limit standard of vehicle. Three-dimensional modeling and simulation was conducted by using MWS(Microwave Studio) of the CST corporation, and the result was compared with the measured RE data, which showed good coincidence each other.

사용 조건하에서의 자동차용 커넥터 신뢰성 분석 (Reliability Analysis of Auto-Connector in Use-condition)

  • 김종걸;김진환
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2004년도 춘계학술대회
    • /
    • pp.129-136
    • /
    • 2004
  • Environmental factors for automotive consist of temperature, humidity, vibration(sine & random), gas, an electrical load and so on. These environmental factors are impressed in a automotive. Dependability is essential requirement in many electronic parts. Among components of automotive, the connector connecting electrical signals is one of the most important parts. Automotive -connector is inspected according to each manufacturer's test standard in which dependability should be considered. This paper aims to verify that current test standard is suitable for dependability, and present an inductive life test for automotive connector based on the field data in use-condition.

  • PDF

퓨즈가 내장된 엘보접속재의 설계 (Design of Fuse Mounted Elbow Connector)

  • 최경선;이철호;송일근;권태종;권영복;한명관
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.383-386
    • /
    • 2000
  • Fuse mounted elbow connector used for pad mounted transformer was designed and investigated. Requirements of electrical ratings such as partial discharge, ac withstand voltage and impulse voltage and material properties were proposed in accordance with IEEE 386 and pre-standard (PS) 147-219∼229 of KEPCO. The connector can be jointed with pad mounted transformer and current limiting fuse which is installed inside of the connector easily replaced with new one in the case of breakdown of the fuse. Electric field analysis was also introduced in other to verify the reliability of the design.

  • PDF

초전도자석 시스템 응용을 위한 멀티-컨텍 커넥터의 열 발생 특성 평가 (Estimation of Heat Generation in Multi-Contact Connector for Superconducting Magnet Application)

  • 김명수;최연석;김동락;이윤아
    • Progress in Superconductivity
    • /
    • 제14권2호
    • /
    • pp.122-127
    • /
    • 2012
  • Current leads are one of the important components for carrying the current to the coil in the superconducting magnet system. Heat leakage through the current lead is the major factor of entire heat load in the cryogenic system because current leads carry the current from room temperature to near 4 K, connecting thermally each other. Therefore, minimization heat load through current lead can reduce the operating temperature of superconducting magnet. The semi-retractable current lead, composed of multi-contact connector and HTS element, is one of good options. Comprehension of Multi-contact connector's structure, contact resistance and heat generation is essential for estimating heat generation in current leads. Multi-contact connector has several louvers inside of socket and the shape, number, size of louvers are different with the size of connector. Therefore contact area, current path and contact resistance are also different. In this study, the contact resistance in multi-contact connector is measured using the electrical power as a function of connector's size and temperature. Also, the unique correlation of electrical contact resistance is derived and heat generation is estimated for superconducting magnet application.

조명등기구 배선용 커넥터의 안전성 평가 및 분석에 관한 연구 (Safety Estimation and Analysis Study of the Connector for Lighting Fixture Wiring)

  • 최충석
    • 전기학회논문지P
    • /
    • 제58권4호
    • /
    • pp.541-545
    • /
    • 2009
  • This study evaluated the contact resistance, insulation resistance, withstand voltage characteristics and insertion force, etc., of the wire connector used inside an integrated LITE WAY lighting fixture developed for efficient installation. Since the connector connecting the lighting fixture's internal wires is housed, it is easily connected and separated and has a structure enabling a close-fitting connection. The temperature and time applied to the high temperature characteristics test of the connector are $105^{\circ}C$ and 16 hours, respectively. The measured contact resistance of the high temperature tested connector was 3.258 mV/A, and its measured insulation resistance was greater than $10\;G{\Omega}$ All specimens demonstrated uniform insulation characteristics, which could be seen to be in good condition. From the withstand voltage test results found before and after performing the high temperature operation test on the connector for cable connection, it was confirmed that the withstand voltage characteristics between all terminals were good. The insertion force of the connector connecting the internal wiring averaged 9.67 kgf. It was observed that the insertion force between the plug housing and the female terminal, and that between the plug housing and the male terminal, were 0.680 kgf and 1.27 kgf on average, respectively.

유한요소해석을 통한 전기 커넥터의 압착 품질 향상 (Quality Improvement for Crimping Process of Electrical Connector Using FEM Analysis)

  • 윤철호;박진기;최현순;김영석
    • 소성∙가공
    • /
    • 제18권3호
    • /
    • pp.229-235
    • /
    • 2009
  • This paper covers finite element simulations to evaluate the terminal crimping process of automobile electrical connector. Crimping is a classical technology process to ensure the electrical and the mechanical link between a wire and a terminal. Numerical modeling of the process is helpful to choose and to optimize the dimensions of the crimping part of the connector. In this paper, we discuss a 2D simulation of the crimping process, using explicit finite element methods (ABAQUS/Explicit) and we compare the results with experimental data from the industrial process of crimping (crimping height, crimping width and compressibility). The explicit method is preferred for the modeling of multi-contact problems, in spite of the quasi-static process of crimping. As compared with CAE analysis, a performance improvement makes certain of the truth of the matter.

고속 직렬 인터페이스 커넥터의 설계 및 분석에 대한 연구 (A Study of Design and Analysis on the High-Speed Serial Interface Connector)

  • 이호상;신재영;최대일;나완수
    • 한국전자파학회논문지
    • /
    • 제27권12호
    • /
    • pp.1084-1096
    • /
    • 2016
  • 본 논문에서는 12.5 Gbps의 전송 속도를 갖는 고속 직렬 인터페이스 커넥터(high-speed serial interface connector)의 설계 및 분석 방법을 제안한다. 고속 직렬 인터페이스 커넥터는 다양한 매질로 구성되며, 내부 선로도 복잡한 구조를 가지고 있으므로, 선로의 불연속 부분의 각각을 임피던스 정합하기가 매우 어렵다. 따라서 커넥터의 각 부분을 단순화한 커넥터 라인(connector line)의 구조를 제안하였으며, 이 구조에서 R, L, C, G 파라미터를 추출하고 차동 모드 임피던스를 분석하며, TDT(Time Domain Transmissometry)와 TDR(Time Domain Reflectometry)을 이용하여 임피던스 불연속(impedance discontinuity)을 최소화 하는 방법을 제시한다. 본 논문은 단순화한 커넥터 라인에서 추출된 분석 방법 및 결과를 고속 직렬 인터페이스 커넥터에 적용하였다. 제안한 커넥터는 총 44개의 핀(pin)으로 구성되며, 본 논문에서는 4개의 핀의 폭과 간격을 변경하여 신호 전달 특성을 분석하였다. 분석결과, 접지 핀의 폭이 증가할수록 임피던스는 소폭으로 감소하고, 접지핀과 신호 핀 사이의 간격이 증가할수록 임피던스가 증가했다. 또한, 신호 핀의 폭을 증가시키면 임피던스가 감소하며, 신호 핀과 신호 핀 사이의 간격을 늘리면 임피던스가 증가하였다. 최초 커넥터 임피던스 특성은 $96{\sim}139{\Omega}$ 사이에서 변화되는 값을 나타내었으나, 제안된 커넥터 구조를 적용했을 때 임피던스 특성은 $92.6{\sim}107.5{\Omega}$ 사이의 값으로 나타나, 설계 목표 $100{\Omega}{\pm}10%$를 만족함을 보였다.

실내 마이크로파 배전 전송계를 위한 가변전력분배기와 도파관의 결합구조 설계 (Design of Variable Power Distributor and Waveguide Connecting Structure for Wireless Microwave Power Transmission in a Building)

  • 최영규
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1477-1482
    • /
    • 2012
  • This paper deals with a new variable microwave power distributor and a connector between a deck plate and a input power waveguide for indoor microwave wireless power transmission. We design a new type connector built in the 3-stage coaxial line structure, and calculate the return loss of the connector at 2.45GHz. Newly designed connector shows the excellent return loss performance less than -30dB at the operating frequency of 2.45GHz. And we show a power distributor in which the dividing ratio of the power is controlled mechanically by three rotary fins. The distributor can control the dividing power from 4.5% to 58% with the variance of 5% output power. The experimentally tested results of the distributor are good agreement with the simulation within the return loss of 1%.

원형 동축 선로에서 광대역 매칭 커넥터의 특성 연구 (A Study on the Characteristics of Wide Band Matching Connector in Round Coaxial Lines)

  • 김병우
    • 한국자동차공학회논문집
    • /
    • 제20권5호
    • /
    • pp.152-157
    • /
    • 2012
  • In this paper, smoothing plane connector have been proposed as the vehicle connector for the wireless access in vehicular environments (5.925GHz) communication. This smoothing plane connector is designed by considering the properties of critical parameter like smoothing distance of start to end point of contact area. The design simulation and results can be used to determine the most suitable smoothing plane wire dimensions for vehicle communication connector. The optimized WAVE connector inserted the smoothing plane wire has insertion loss less than-0.17dB at 5.925GHz. It provides 20% of insertion loss with good performance. Therefore, the simulated results can be effectively used for optimum design of high frequency connector for vehicle communication.

Electrical Impedance Change due to Contamination at the Contact Interface of Connectors for Automobile Crank Shaft Position Sensor

  • Kim, Young-Tae;Sung, In-Ha;Kim, Dae-Eun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제5권2호
    • /
    • pp.46-52
    • /
    • 2004
  • Numerous connectors are used in automobiles for transmission of electrical signals across various electro-mechanical components. The connectors must operate with high reliability in order to minimize failures due to signal degradation. In this work, the effects of contamination at the contact interface of connectors used fur automobile crankshaft position sensor on the impedance change were investigated. An experimental set-up was built to simulate the electrical signal transmitted from the sensor to the engine control unit through a connector. Output from the connector was investigated using connectors contaminated with engine block residues and water droplets. It was found that slight contamination of the connectors could lead to significant signal degradation which can lead to engine failure. Also, the effect of water in the connector altered the signal severely. However, the signal gradually regained the original state as the water evaporated from the interface.