• 제목/요약/키워드: Electrical and electronic equipments

검색결과 192건 처리시간 0.023초

170kV GIS용 단로기의 현장 사용 실태 조사 (A Study on the Actual Condition Investigation of the Disconnecting Switchgear of 170kV GIS)

  • 이은석;김종서;천종철
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.2
    • /
    • pp.1180-1183
    • /
    • 2003
  • 170kV GIS(Gas Insulated Switchgear) is widely used in large industrial factory-electrical facilities of private use because has many benefits. But Other equipments's failures are occurred by GIS failures and give rise economic problems to user. Therefore we will examine the actual condition of the 170kV GIS-electrical facilities of private use and are able to confirm the distribution characteristic analysis of disconnecting switchgear. In this paper, we presents the actual condition investigation of the disconnecting switchgear of 170kV GIS-electrical facilities of private use by post - failure pattern, inspection method, test equipments and so forth.

  • PDF

전파응용설비 관리제도 개선방안 연구 (A Study on an Improvement Scheme of ISM Management Regulation)

  • 박연규;조현묵;이일규
    • 한국전자파학회논문지
    • /
    • 제27권7호
    • /
    • pp.581-587
    • /
    • 2016
  • 최근 전파응용설비의 다양화 및 50와트를 초과하는 고출력 설비의 이용이 가정, 의료기관 및 산업현장에서 확대됨에 따라 허가대상 설비가 대폭 증가하였다. 이로 인해 각각의 설비를 개별적으로 허가하고, 전수를 검사하는 현재의 허가체계는 한계성을 가지고 있으며, 환경변화 등의 현실을 반영하기 어렵다. 본 논문에서는 해외 주요국의 전파응용설비 관련제도와 국내 제도를 조사하고, 이를 토대로 국내 환경에 적합한 전파응용설비 관리제도 개선방안을 제안하였다. 이 결과는 향후 전파응용설비 관련 산업 활성화와 전파응용설비의 효율적인 관리를 위한 전파응용설비 관리제도를 개선하는데 유용한 자료로 사용될 것이다.

건축물 전기설비의 고조파에 관한 사례연구 (A Case Study of Harmonics in Electrical Installations of Buildings)

  • 고희석;김성삼;이현무;김주찬;류희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2003년도 학술대회논문집
    • /
    • pp.283-288
    • /
    • 2003
  • This paper presents the result of survey of case study for Harmonics in electrical Installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. However, there are some difficulties on evaluating the measured data in comparison with the simulated result. The primary cause was indentitied with the resonance of harmonics form many sources. To suppress harmonics in electrical installations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF

회로구성이 가능한 인터넷 기반의 원격 실험실 구축에 관한 연구 (Developement of Web-Based Circuit-Constructible remote Laboratory)

  • 정성훈;김호성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 D
    • /
    • pp.2603-2605
    • /
    • 2001
  • In this paper, we introduce the concept and construction of a web-based bidirectional remote laboratory system. In this configuration, students build and test circuits using internet at home, and the circuit components and experimental equipments at the school are interconnected following student's design. This means that it is possible to choose components, build circuits, connect experiment equipments, control the equipment. and receive measurement results at home in real-time. Labview and Java are used to control this system efficiently and to provide user-friendly environments. Computer-based function generator, DMM, and oscilloscope are used and switch module is used to change interconnections. It was found that a system adopting computer-based instruments, which include PXI/CompactPCI modules and PC plug-in board, provide better performance than that adopting stand-alone instruments connected with GPIB. It is believed that, if this system is installed, the real experiments, not the virtual experiments based on simulation, can be done at home effectively, resulting in revolutional change in engineering education.

  • PDF

전력선통신을 이용한 전력품질 측정시스템 (Power Quality Measurement System of using PLC)

  • 홍덕표;이진목;최재호
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2005년도 전력전자학술대회 논문집
    • /
    • pp.90-92
    • /
    • 2005
  • As the developing of industry, the nonlinear equipments as inverter, converter, SMPS(Switching Mode Power Supply) and motor have been increased. But the sensitive electronic loads to the power quality, such as computer's and other electronic equipments, have been spreaded out very fast. Thus, the power quality (PQ) problems and the real time power quality monitoring (PQM) are one of the important issues industry and building area for the intelligent control of the systems. One of them, PQM using PLC(Power Line Communication) have good merits that can send and receive the PQ information without any new network line. This paper presents the PQM hardware and software to monitor the PQ information by using PLC that meets the categories of IEEE Std. 1159.

  • PDF

A Web-based Virtual Laboratory System For Electronic Circuit Experiments

  • Kim, Dong-Sik;Seo, Sam-Jun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2003년도 ICCAS
    • /
    • pp.1794-1797
    • /
    • 2003
  • We developed a web-based virtual laboratory system for electronic circuit experiments on the client/ server distributed environment. Through our virtual laboratory, the learners will be capable of learning the concepts and theories related to electronic circuit experiments and how to operate the experimental equipments such as multimeters, function generators, digital oscilloscopes and DC power suppliers. The proposed virtual laboratory system is composed of four important components: Principle Classroom to explain the concepts and theories of electronic circuit operations, Virtual Experiment Classroom to provide interactive multimedia contents about the syllabus of off-line laboratory class, Assessment Classroom, and Management System. With the aid of the Management System every classroom is organically tied together collaborating to achieve maximum learning efficiency. We have obtained several affirmative effects such as high learning standard, reducing the total experimental hours and the damage rate for experimental equipments.

  • PDF

Electrical Strength of the Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck-Kweon;Kim, Chung-Hyeok;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Song, Min-Jong;Lee, Joon-Ung
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.149-150
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of unfilled epoxy and filled epoxy in $LN_2$ was analyzed. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.

  • PDF

SPD의 설치조건이 보호효과에 미치는 영향 (Protection Effects Associated with Installation Conditions of SPD)

  • 이복희;이동문;정동철;이승칠
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.298-302
    • /
    • 2005
  • This paper presents the protection effect of SPDs according to installation conditions. To develop the effective protection countermeasures of information and communication equipments against lightning surges, actual-sized experiments in relation to the protection effects on the installation positions of surge protective devices(SPDs), the length of branch circuit the materials and long of conduit were conducted. The best method for protecting the electronic equipments from surges is to install the SPD at the front point of the devices to be protected. The installation method of the metal conduit bonded with common ground conductor were more effective than that of the PVC conduit.

  • PDF

Development of the ANN for the Estimation of Earth Parameter and Equivalent Resistivity

  • Ji Pyeong-Shik;Lee Jong-Pil;Shin Kwan-Woo;Lim Jae-Yoon;Kim Sung-Soo
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권4호
    • /
    • pp.350-356
    • /
    • 2005
  • Earth equipments are essential to protect humans and other types of equipment from abnormal conditions. Earth resistance and potential must be restricted within a low value. An estimation algorithm of earth parameters and equivalent resistivity is introduced to calculate reliable earth resistance in this research. The proposed algorithm is based on the relationship between apparent resistances and earth parameters. The proposed algorithm, which approximates the non-linear characteristics of earth by using the Artificial Neural Network (ANN), estimates the earth parameters and equivalent resistivity. The effectiveness of the proposed method is verified with case studies.

고압수전설비의 고조파에 관한 대책 (The Countermeasure about Harmonics of the High Voltage Power Facilities)

  • 김주찬;신수한;이충식;고희석
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.353-357
    • /
    • 2004
  • This paper presents the result of survey of case study for harmonics in electrical installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. To suppress harmonics in electrical ins tallations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF