An Improved Technique for Fault Location Estimation Considering Shunt Capacitance on Transmission Line

  • Kim Hyun-Houng;Jeong Yun-Won;Lee Chan-Joo;Park Jong-Bae;Shin Joong-Rin
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.295-301
    • /
    • 2006
  • This paper presents a new two-terminal numerical algorithm for fault location estimation using the synchronized phasor in time-domain. The proposed algorithm is also based on the synchronized voltage and current phasor measured from the PMUs (Phasor Measurement Units) installed at both ends of the transmission lines. In this paper, the algorithm is given without shunt capacitance and with shunt capacitance using II -model and estimated using DFT (Discrete Fourier Transform) and LES (Least Error Squares Method). The algorithm uses a very short data window and classification for real-time transmission line protection. To verify the validity of the proposed algorithm, the Electro-Magnetic Transient Program (EMTP) and MATLAB are used.

Short-term Effect of Phosphogypsum on Soil Chemical Properties

  • Chung, Jong-Bae;Kang, Sun-Chul;Park, Shin
    • Korean Journal of Environmental Agriculture
    • /
    • v.20 no.5
    • /
    • pp.317-324
    • /
    • 2001
  • Short-term effect of phosphogypsum on soil properties including acidification, salinity and metal availability were investigated under laboratory and field conditions. Phosphogypsum and mixtures of phosphogypsum and compost were added to soil and incubated in a laboratory condition with 15% moisture content. Phosphogypsum treatments were 2.5 and 5.0 g/kg soil and in the treatments of phosphogypsum and compost mixture 10 g of compost was added additionally. After the 30 days of incubation, an additional phosphogypsum and/or compost were added to the remaining soils at the same rates of the first treatments. pH, electrical conductivity, and available hazardous elements were measured periodically during the incubation. Field experiment was conducted in a plastic film house of mellon with four treatments of phosphogypsum and compost mixtures - 25+125, 50+125, 50+250 and 100+250 kg/165 $m^2$. pH, electrical conductivity, and hazardous elements in soil and total hazardous elements in leaf were measured. In the laboratory experiment, after 30 days of the first phosphogypsum application, soil pHs were lowered by 0.7-0.8 units. After the second treatment of phosphogypsum 0.2 units of additional acidification occurred. However, acidification was not observed in the soils treated with mixtures of phosphogypsum and compost. In the laboratory experiment, phosphogypsum treatments increased electrical conductivity very significantly. In field experiment, pH and electrical conductivity of soils treated with phosphogypsum were nearly the same as those of soil not treated with phosphogypsum. Since soil condition in the field study was an open system, the free acids and salts derived from phosphogypsum could be diffused down with water leaching through the soil profile and then any significant acidification or salt accumulation in the topsoil could not be observed. In both laboratory and field experiments, levels of available hazardous elements in soils treated with phosphogypsum were quite low and not different from the levels found in the control soil. Results obtained from this study suggest that application of phosphogypsum at appropriate rates on agricultural land appears of no concern in terms of acidity, salinity and hazardous element content of soil.

  • PDF

A Study on the Determination and Application of the Optimum Load Shedding Schemes (최적부하제한방식의 결정과 운용에 관한 연구)

  • Song, Kil-Yeong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.34 no.1
    • /
    • pp.29-37
    • /
    • 1985
  • During Severe emergencies which result in the case of outage of large generator units, an automatic underfrequency protection scheme can prevent the system frequency from decaying and improve the system stability. This paper presents methods and results of a study on the optimum load shedding scheme which covering as follows. 1) Detail representation of governor model 2) Determination of optimum load shedding amount 3) Selection of action time settings of UFR 4) Comparsson of load shedding programs By this study, the optimum system operating method was recommended for reliable operation of power system.

  • PDF

Analysis of the 74LS381 ALU and Design of an Equivalent Circuit to the 74L (74LS381 ALU의 분석 및 등가회로의 설계)

  • Lee, Jae-Seok;Chung, Tae-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.153-156
    • /
    • 2001
  • This paper analyzes the 74LS381 ALU and designs its equivalent circuit. The 74LS381 ALU is arithmetic logic units(ALUs)/function generators that perform eight binary arithmetic/logic operations on two 4-bit words. However there are only little information to understand and design this circuit. Thus, we not only analyzed it but also designed an equivalent circuit to the 74LS381.

  • PDF

COMS System Bus Design and Analysis using MIL-STD-1553B (MIL-STD-1553B 버스를 이용한 통신해양기상위성의 시스템 버스 설계 및 분석)

  • Cho, Young-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.7
    • /
    • pp.1285-1289
    • /
    • 2008
  • In this paper, we design COMS system bus that the 1553 Data Bus is able to link all the units of the satellite managed by the SCU using one Prime Data Bus and on Redundant Data Bus. Also we analyze MIL-STD-1553B bus load and relevant exchange memory budgets in system bus of the COMS satellite. This data is used in the satellite mission and software design by system engineer.

A Design of Vector Processing Based 3D Graphics Geometry Processor (벡터 프로세싱 기반의 3차원 그래픽 지오메트리 프로세서 설계)

  • Lee, Jung-Woo;Kim, Ki-Chul
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.989-990
    • /
    • 2006
  • This paper presents a design of 3D Graphics Geometry processor. A geometry processor needs to cope with a large amount of computation and consists of transformation processor and lighting processor. To deal with the huge computation, a vector processing structure based on pipeline chaining is proposed. The proposed geometry processor performs 4.3M vertices/sec at 100MHz using 11 floating-point units.

  • PDF

Design Considerations on Partition of SOP, CMOS and PCB technologies for Mobile Display System Implementation

  • Lee, Seung-Yong;You, Jae-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.798-801
    • /
    • 2007
  • For lower power and smaller size with higher image quality, it is desirable to have more units integrated on a display panel. It needs careful design considerations in selecting CMOS, SOP or PCB. An experimental display system is designed and power and delay considering chip area, data rates and bus width are analyzed for all technology combinations to obtain optimum design methodologies.

  • PDF

A Study on Mechanism Stated Number of Electro-Optical Distance Measuring Instrument (광파측거의의 기계정수에 관한 연구)

  • Lee, Y.H.;Mun, D.Y.
    • Journal of Korean Port Research
    • /
    • v.5 no.2
    • /
    • pp.77-84
    • /
    • 1991
  • This paper is compared with fourier series and least square polynomial fit and interpolation to mechanism stated number in electro-optical distance measuring instrument. Systematic instrumental errors occurring in electro-optical systems include uncertainties in the position of the electrical center of the transmitter, uncertainties in the effective center of the reflectors. frequency drift and instrument nonlinearity. Microwave systems are affected by uncertainties in the electrical centers of the master and remote units and by a phenomenon called group swing or reflection. As the result of this study, mechanism stated number will be used as verification of electro0optical measuring instrument to distance measurement.

  • PDF

Load Flow Analysis for Distribution Automation System based on Distributed Load Modeling

  • Yang, Xia;Choi, Myeon-Song;Lim, Il-Hyung;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • v.2 no.3
    • /
    • pp.329-334
    • /
    • 2007
  • In this paper, a new load flow algorithm is proposed on the basis of distributed load modeling in radial distribution networks. Since the correct state data in the distribution power networks is basic for all distribution automation algorithms in the Distribution Automation System (DAS), the distribution networks load flow is essential to obtain the state data. DAS Feeder Remote Terminal Units (FRTUs) are used to measure and acquire the necessary data for load flow calculations. In case studies, the proposed algorithm has been proven to be more accurate than a conventional algorithm; and it has also been tested in a simple radial distribution system.

Two Terminals Numerical Algorithm for Distance Protection, Fault Location and Acing Faults Recognition Based on Synchronized Phasors

  • Lee Chan-Joo;Park Jong-Bae;Shin Joong-Rin;Radojevic Zoran
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • This paper presents a new numerical algorithm for fault location estimation and for faults recognition based on the synchronized phasors. The proposed algorithm is based on the synchronized phasor measured from the synchronized PMUs installed at two-terminals of the transmission lines. In order to discriminate the fault type, the arc voltage wave shape is modeled numerically on the basis of a great number of arc voltage records obtained by transient recorder. From the calculated arc voltage amplitude it can make a decision whether the fault is permanent or transient. The results of the proposed algorithm testing through computer simulation are given.