• 제목/요약/키워드: Electrical Transmission Characteristic

검색결과 301건 처리시간 0.025초

지중송전계통에서 시스유기전압 및 CCPU 동작 특성 해석 (Analysis of Sheath Induced Voltage and CCPU Operating Characteristic in Underground Transmission Cable)

  • 진혜영;이종범;김영;조한구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.494-496
    • /
    • 2001
  • This paper describes sheath induced voltage and operating characteristic of cable cover protection unit(CCPU) in underground transmission cable. Real cable system operating by 154kV XLPE cable was modelled for simulation. Sheath induced voltage and operating characteristic of CCPU were analyzed. In particular, sheath induced voltage was analyzed in case of individual grounding and common grounding, respectively, and operating characteristics of CCPU were compared each other.

  • PDF

과전압 분석 결과와 고장특성을 고려한 기설 송전선로의 절연보강 방법에 관한 연구 (A Study on Insulation Performance Enhancement of Existing Transmission Line Considering Overvoltage Analysis Result and Fault Characteristic)

  • 곽주식;우정욱;구교선;김경탁;권동진
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.162-168
    • /
    • 2009
  • 본 논문은 이미 표준 절연설계 값으로 건설되어 운전중인 송전선로의 절연거리를 과전압분석결과, 뇌사고 및 오손 고장 확률과 특성을 고려하여 재설계하고 소요 애자수량을 결정하기 위하여 수행된 연구결과이다. 송전선로의 절연성능을 훼손하지 않으면서 적절한 절연거리를 확보하기 위하여 EMTP 모델을 이용하여 선로에서 발생 가능한 최대 과전압을 계산하고, 뇌 고장실적 및 뇌사고율 예측계산결과와 오손 고장 확률을 조사 분석하였다. 분석결과로부터 고장 특성을 고려한 소요 애자수량의 결정방법을 제시한다.

Coupling Performance Analysis of a Buried Meshed-Ground in a Multi-layered Structure

  • Joung, Myoung-Sub;Park, Jun-Seok;Kim, Hyeong-Seok;Lim, Jae-Bong;Cho, Hong-Goo
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권6호
    • /
    • pp.282-287
    • /
    • 2004
  • Since the manufacturing process in the LTCC process does not allow solid ground planes between ceramic layers to isolate the signal lines, the buried ground should be realized as a meshed ground plane. Both characteristic impedances of the signal lines and couplings between different signal layers are influenced by the properties of these meshed planes. In this paper, we propose a new analysis method for coupling behavior between internal transmission lines, which are isolated by the buried meshed-ground planes. The coupling behavior between layers isolated by meshed-ground planes is investigated by the coupled-transmission line model for the isolated layers. The coupling factors between isolated lines with the meshed-ground are extracted by 2-D FEM calculations.

극초고주파용 CPW의 결합노이즈특성에 관한 연구 (A Studying on the Crosstalk Characteristic of mm-wave Coplanar-waveguide)

  • 장인범;박재준;이준웅
    • 한국전기전자재료학회논문지
    • /
    • 제19권2호
    • /
    • pp.158-161
    • /
    • 2006
  • The purpose of this research is to establish the crosstalk characteristic of mm-wave Coplanar structure. The components in mm-wave CPW are classified to transmission devices, EM devices, and quasi - TEM devices. After design of these devices, we analyzed these CPW s electromagnetically using FDTD method, and suggested the corsstalk characteristic of mm-wave CPW. In oder to realize a CPW module up to 30 GHz-100 GHz band, we research on a technology of 3-dimensional mm-wave CPW, and GaAs substrate with ohmic lossy layer. As a result this research, we suggested the optimum crosstalk characteristic of mm-wave CPW, and improved the crosstalk quality of mm-wave CPW.

Epoxy/EPDM 거시계면의 최적조건과 V-t 특성 (Optimal Pressure Condition and V-t Characteristic of Macro Interface between Epoxy and EPDM)

  • 박우현;이동규;이상극;안준호;김충혁;이기식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집
    • /
    • pp.439-442
    • /
    • 2002
  • The interface between two different materials in the insulation systems is the weak-link in the underground power transmission systems, In this paper, Optimum conditions of the interface between Epoxy and EPDM is studied. The variation factor condition of interface is roughness of surface, spreading of oils, interfacial pressure and temperature. The breakdown times under the constant voltage below the breakdown voltage were also gained. The breakdown voltage at the after laying time equivalent to is calculated by the V-t characteristic and the inverse power law. When this is done, the characteristic life exponent n is used and the long time breakdown voltage can be evaluated.

  • PDF

전기적인 거리를 고려한 한계송전손실계수 산정 방법론 개발 (Development of Evaluation Method for Transmission Marginal Loss Factors Considering the Electrical Distance)

  • 박종배;이기송;이찬주;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.488-490
    • /
    • 2003
  • This paprer presents the evlauation method for transmission marginal loss factors(MLFs) considering the electrical distance. Generally, MLFs are represented as the sensitivity of transmission losses, which is computed from the change of generation by the change of the load. MLFs are classified as load-focused MLFs and generator-focused MLFs. The existing evaluation method for generator focused MLFs has the limit not reflecting the characteristic of power systems since the method has been introduced the assumption which the output of a generator is supplied to all of the load buses on the power system. Therefore, to overcome the limit of evaluation method for generator-focused MLFs, we have applied the process, which it approximately can find the load buses that supplied a generator to the method. We have applied the proposed method to the simple 5-bus system because the proposed method is not analytic but the hybrid method incorporated the Kirschen and Bialek's algorithm to the existing analytic method to find the load buses supplied by a generator.

  • PDF

Space Charge Behavior of Oil-Impregnated Paper Insulation Aging at AC-DC Combined Voltages

  • Li, Jian;Wang, Yan;Bao, Lianwei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.635-642
    • /
    • 2014
  • The space charge behaviors of oil-paper insulation affect the stability and security of oil-filled converter transformers of traditional and new energies. This paper presents the results of the electrical aging of oil-impregnated paper under AC-DC combined voltages by the pulsed electro-acoustic technique. Data mining and feature extractions were performed on the influence of electrical aging on charge dynamics based on the experiment results in the first stage. Characteristic parameters such as total charge injection and apparent charge mobility were calculated. The influences of electrical aging on the trap energy distribution of an oil-paper insulation system were analyzed and discussed. Longer electrical aging time would increase the depth and energy density of charge trap, which decelerates the apparent charge mobility and increases the probability of hot electron formation. This mechanism would accelerate damage to the cellulose and the formation of discharge channels, enhance the acceleration of the electric field distortion, and shorten insulation lifetime under AC-DC combined voltages.

An Accurate Model of Multi-Type Overcurrent Protective Devices Using Eigensystem Realization Algorithm and Practice Applications

  • Cheng, Chao-Yuan;Wu, Feng-Jih
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권1호
    • /
    • pp.9-19
    • /
    • 2016
  • Accurate models of the characteristics of typical inverse-time overcurrent (OC) protective devices play an important role in the protective coordination schemes. This paper presents a novel approach to determine the OC protective device parameters. The approach is based on the Eigensystem Realization Algorithm which generates a state space model to fit the characteristics of OC protective devices. Instead of the conventional characteristic curves, the dynamic state space model gives a more exact fit of the OC protective device characteristics. This paper demonstrates the feasibility of decomposing the characteristic curve into smooth components and oscillation components. 19 characteristic curves from 13 typical and 6 non-typical OC protective devices are chosen for curve-fitting. The numbers of fitting components required are determined by the maximum absolute values of errors for the fitted equation. All fitted equations are replaced by a versatile equation for the characteristics of OC protective devices which represents the characteristic model of a novel flexible OC relay, which in turn may be applied to improve the OC coordination problems in the sub-transmission and distribution systems.

Suppression of Glow Corona on Streamer and Influence of Thin Wire on its Inception

  • Sima, Wenxia;Fan, Shuochao;Yang, Qing;Wang, Qi
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1759-1764
    • /
    • 2015
  • Glow corona is a kind of streamer-free corona that can suppress upward leaders in transmission lines. Thus, it has good application potential in lightning protection. This paper investigates its corona characteristics. The suppression characteristic of glow corona on streamer is studied in air gap under negative DC voltage by wrapping thin wires on the electrode. The effect of thin wire winding patterns on the gap breakdown voltage is analyzed. Results are considered to be attributed to the inception condition of glow corona. Thus an inception test of glow corona is also conducted, and the inception voltage is obtained. Results show that the inception voltage decreases with short winding pitch. Thus an investigation on the inception of glow corona influenced by thin wire is conducted, and an influential factor is proposed to evaluate the influence. The inception regular of thin wire glow corona presented in this paper has certain reference value for the application of glow corona in transmission lines.

구내통신의 배선구조와 광대역 전기적 특성 (The structrue and wideband electrical characteristics of premises telecommunicatin wiring)

  • 이강식;김창락;류명주;서태석
    • 한국통신학회논문지
    • /
    • 제23권9A호
    • /
    • pp.2165-2172
    • /
    • 1998
  • Existing premises telecommucation wiring ad been installed for efficient telephone service. But premises wiring is currently ready to be reused as media for wideband digital services and Fiber-to-the-curb architecture. Electrical properties of premises wiring link have not characateized above frequencies for voice service. Accurte measurement of these characteristics are exssential for studies fof wideband ditital transmission system. On the other hand, the transmission qualities of premises wiring have been known to be worst in telecommunications access networks. So the knowledge of premises wiring sturucture as well as electrical properties is needed to improve the performance of premises wiring. In this paper, the structure of premises wiring is described in detail and electrical characteristics (characteristic impedance, SRL, attnuation, NEXT) about premises cables and stelecommucations link of representative apartment complex sare measured and naalyzed ove r16MHz range which is UTP Cat3 bandwidth.

  • PDF